Review



pepperchip© microarray  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier
Bioz Manufacturer Symbol Thermo Fisher manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Thermo Fisher pepperchip© microarray
    Pepperchip© Microarray, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pm39890694-55-1-10
    Average 90 stars, based on 1 article reviews
    pepperchip© microarray - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: HCV immunodominant peptide mapping reveals unique HLA-A*02-restricted signatures: insights for CD8 + T-cell-based vaccines and immunotherapies.
    Article Snippet: Several barriers for the development of an HCV vaccine still exist, including the genetic diversity of the virus, and the shortage of assessable models for in vitro and in vivo assays.. Therefore, in this study, HCV epitope mapping was performed for 59 polyprotein sequences from 7 HCV genotypes.. Around 2,880 peptides were considered epitopes for CD8+ T cells.



    Similar Products

    90
    Thermo Fisher pepperchip© microarray
    Pepperchip© Microarray, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pm39890694-55-1-10
    Average 90 stars, based on 1 article reviews
    pepperchip© microarray - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    PEPperPRINT gmbh pepperchip© custom peptide microarray
    Pepperchip© Custom Peptide Microarray, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pepperchip+peptide+microarrays/pm39890694-45-31-28
    Average 90 stars, based on 1 article reviews
    pepperchip© custom peptide microarray - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    PEPperPRINT gmbh custom peptide microarray pepperchip ©
    Custom Peptide Microarray Pepperchip ©, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pepperchip+peptide+microarrays/pm36979478-53-10-15
    Average 90 stars, based on 1 article reviews
    custom peptide microarray pepperchip © - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    PEPperPRINT gmbh pepperchip © custom peptide microarray
    Pepperchip © Custom Peptide Microarray, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pepperchip+peptide+microarrays/pmc10046496-44-10-15
    Average 90 stars, based on 1 article reviews
    pepperchip © custom peptide microarray - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    PEPperPRINT gmbh pepperchip© microarray
    Pepperchip© Microarray, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pepperchip+microarray/pm36466864-62-14-16
    Average 90 stars, based on 1 article reviews
    pepperchip© microarray - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    PEPperPRINT gmbh pepperchip © microarray
    Panoramic Evaluation of HLA-A*02:01 Reactivity for Peptides Derived from Arbovirus. Peptide <t>microarray</t> was performed with an HLA-A*02:01 dimeric protein in three concentrations (1µg/mL, 10µg/mL and 30µg/mL). Overall fluorescence of peptide-HLA-A*02:01 reactivity (top panels), absolute number of HLA-*02:01-reactive peptides (middle panels) and mean of fluorescence intensity of HLA-*02:01-reactive peptides (lower panels) were evaluated. Chi-square test (χ2) was used to compare the number of HLA-A*02:01-reactive. Obtained p values are indicated above each bar. Comparisons regarding the mean of fluorescence intensity of HLA*02:01-reactive peptides were performed using the Kruskal-Wallis. Statistical significances were considered for p < 0.05 and are indicated by connecting lines.
    Pepperchip © Microarray, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pepperchip+microarray/pmc09713826-43-17-12
    Average 90 stars, based on 1 article reviews
    pepperchip © microarray - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    PEPperPRINT gmbh pepperchip r© peptide microarrays
    Panoramic Evaluation of HLA-A*02:01 Reactivity for Peptides Derived from Arbovirus. Peptide <t>microarray</t> was performed with an HLA-A*02:01 dimeric protein in three concentrations (1µg/mL, 10µg/mL and 30µg/mL). Overall fluorescence of peptide-HLA-A*02:01 reactivity (top panels), absolute number of HLA-*02:01-reactive peptides (middle panels) and mean of fluorescence intensity of HLA-*02:01-reactive peptides (lower panels) were evaluated. Chi-square test (χ2) was used to compare the number of HLA-A*02:01-reactive. Obtained p values are indicated above each bar. Comparisons regarding the mean of fluorescence intensity of HLA*02:01-reactive peptides were performed using the Kruskal-Wallis. Statistical significances were considered for p < 0.05 and are indicated by connecting lines.
    Pepperchip R© Peptide Microarrays, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/pepperchip%C2%A9+microarray/pepperchip+peptide+microarrays/pm25982269-161-18-23
    Average 90 stars, based on 1 article reviews
    pepperchip r© peptide microarrays - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Panoramic Evaluation of HLA-A*02:01 Reactivity for Peptides Derived from Arbovirus. Peptide microarray was performed with an HLA-A*02:01 dimeric protein in three concentrations (1µg/mL, 10µg/mL and 30µg/mL). Overall fluorescence of peptide-HLA-A*02:01 reactivity (top panels), absolute number of HLA-*02:01-reactive peptides (middle panels) and mean of fluorescence intensity of HLA-*02:01-reactive peptides (lower panels) were evaluated. Chi-square test (χ2) was used to compare the number of HLA-A*02:01-reactive. Obtained p values are indicated above each bar. Comparisons regarding the mean of fluorescence intensity of HLA*02:01-reactive peptides were performed using the Kruskal-Wallis. Statistical significances were considered for p < 0.05 and are indicated by connecting lines.

    Journal: Frontiers in Immunology

    Article Title: In silico and in vitro arboviral MHC class I-restricted-epitope signatures reveal immunodominance and poor overlapping patterns

    doi: 10.3389/fimmu.2022.1035515

    Figure Lengend Snippet: Panoramic Evaluation of HLA-A*02:01 Reactivity for Peptides Derived from Arbovirus. Peptide microarray was performed with an HLA-A*02:01 dimeric protein in three concentrations (1µg/mL, 10µg/mL and 30µg/mL). Overall fluorescence of peptide-HLA-A*02:01 reactivity (top panels), absolute number of HLA-*02:01-reactive peptides (middle panels) and mean of fluorescence intensity of HLA-*02:01-reactive peptides (lower panels) were evaluated. Chi-square test (χ2) was used to compare the number of HLA-A*02:01-reactive. Obtained p values are indicated above each bar. Comparisons regarding the mean of fluorescence intensity of HLA*02:01-reactive peptides were performed using the Kruskal-Wallis. Statistical significances were considered for p < 0.05 and are indicated by connecting lines.

    Article Snippet: Evaluation of the HLA-A*02-restricted immunodominant peptide repertoire was performed using PEPperCHIP © (PEPperPRINT © , Heidelberg, Germany) custom peptide microarray ( ).

    Techniques: Derivative Assay, Peptide Microarray, Fluorescence