high-density, small field diode array srs mapcheck (Sun Nuclear Corporation)
Structured Review
High Density, Small Field Diode Array Srs Mapcheck, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck/srs+mapcheck+diode+array/pm40570651-106-12-6
Average 90 stars, based on 1 article reviews
Images
Related Articles
Software:Article Title: Impact of systematic MLC positional uncertainties on the quality of single‐isocenter multi‐target VMAT‐SRS treatment plans Article Snippet: Dose delivery involved four non‐coplanar arcs (as in the simulation study) and was carried out by a clinical VersaHD 6MV FFF linac (ELEKTA, Crawley, UK), equipped with an Agility treatment head. .. Prior to measurements, the other:Article Title: Hypofractionated stereotactic radiotherapy using coplanar VMAT for single small brain metastasis: dosimetric analysis and clinical outcomes Article Snippet: A high-density diode array SRS MapCHECK TM combined with a Article Title: Development of a high‐resolution two‐dimensional detector‐based dose verification system for tumor‐tracking irradiation in the CyberKnife system Article Snippet: Recently, the Article Title: Small field commissioning and verification for the uRT-TPOIS radiotherapy treatment planning system. Article Snippet: Purpose: Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) plans involve high doses and small fields.. Standard commissioning procedures typically do not prioritize small fields, which is why the commission parameters of small field models require a comprehensive and precise verification process to ensure accurate dose calculation for SRS/SBRT plans.. Methods: The study employed various methods, including dose validation tests in a water tank with both regular and irregular small fields. Produced:Article Title: Impact of systematic MLC positional uncertainties on the quality of single‐isocenter multi‐target VMAT‐SRS treatment plans Article Snippet: .. Moreover, the commercially available StereoPHAN phantom in combination with the Biomarker Discovery:Article Title: Generation, validation, and benchmarking of a commercial independent Monte Carlo calculation beam model for multi-target SRS. Article Snippet: .. After beam data acquisition, modeling, & validation, a series of end-to-end tests comparing the SciMoCa Monte Carlo calculation to measurements with (1) the |
