Review



synergi  (Danaher Inc)


Bioz Verified Symbol Danaher Inc is a verified supplier
Bioz Manufacturer Symbol Danaher Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    Danaher Inc synergi
    Synergi, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 232 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/pm42883601-106-6-18
    Average 95 stars, based on 232 article reviews
    synergi - by Bioz Stars, 2026-11
    95/100 stars

    Images

    Related Articles

    Pore Size:

    Article Title: Comparative assessment of pesticide residue profiles and chronic dietary exposure in nectarines imported into Egypt
    Article Snippet: The chromatographic determination was carried out using an AB SCIEX QTRAP 6500 + tandem mass spectrometer integrated with a Shimadzu LC-20 HPLC system (Kyoto, Japan) (Malhat et al., 2026). .. Chromatographic separation was performed on a Phenomenex Synergi Fusion-RP column (2.5 μm particle size, 100 Å pore size, 3.0 mm i.d. ..

    High Performance Liquid Chromatography:

    Article Title: Effect of Rearing System and Season on Herbage Intake, Performance and Meat Nutritional Quality of Growing Rabbits
    Article Snippet: .. Samples were analyzed using an HPLC system equipped with a fluorescence detector and a Synergi Hydro-RP column (4 μm, 4.6 × 100 mm; Phenomenex, Bologna, Italy). ..

    Fluorescence:

    Article Title: Effect of Rearing System and Season on Herbage Intake, Performance and Meat Nutritional Quality of Growing Rabbits
    Article Snippet: .. Samples were analyzed using an HPLC system equipped with a fluorescence detector and a Synergi Hydro-RP column (4 μm, 4.6 × 100 mm; Phenomenex, Bologna, Italy). ..

    Analysis:

    Article Title: Improving wastewater-pulse detection in karst groundwater: Integrating online monitoring with chemical and microbiological indicators
    Article Snippet: In short, 1 mL of the water sample was mixed with 20 μL of internal standard and centrifuged at 10, 000 rpm and 8 ◦C for 10 min (IKA mini-G). .. For the analysis, OMPs were separated by chromatography using a C18 column (Phenomenex Synergi 4 μm Fusion-RP, 80 Å LC Column, 50 × 2 mm) with a flow rate of 0.40 mL/min, a temperature of 50 ◦C, and an injection volume of 50 μL. ..

    Chromatography:

    Article Title: Improving wastewater-pulse detection in karst groundwater: Integrating online monitoring with chemical and microbiological indicators
    Article Snippet: In short, 1 mL of the water sample was mixed with 20 μL of internal standard and centrifuged at 10, 000 rpm and 8 ◦C for 10 min (IKA mini-G). .. For the analysis, OMPs were separated by chromatography using a C18 column (Phenomenex Synergi 4 μm Fusion-RP, 80 Å LC Column, 50 × 2 mm) with a flow rate of 0.40 mL/min, a temperature of 50 ◦C, and an injection volume of 50 μL. ..

    Liquid Chromatography:

    Article Title: Improving wastewater-pulse detection in karst groundwater: Integrating online monitoring with chemical and microbiological indicators
    Article Snippet: In short, 1 mL of the water sample was mixed with 20 μL of internal standard and centrifuged at 10, 000 rpm and 8 ◦C for 10 min (IKA mini-G). .. For the analysis, OMPs were separated by chromatography using a C18 column (Phenomenex Synergi 4 μm Fusion-RP, 80 Å LC Column, 50 × 2 mm) with a flow rate of 0.40 mL/min, a temperature of 50 ◦C, and an injection volume of 50 μL. ..

    Article Title: SPEAR: Spatial Epitranscriptomic Analysis by Mass Spectrometry Reveals Localized RNA Modification Remodeling During Glioma Progression
    Article Snippet: Nucleosides were separated using a Nexera LC system from Shimadzu. .. The reference method was performed on a Nexera LC-40 system equipped with a Synergi Fusion-RP column (250×2mm, 4μm, 80A, 00G-4424-B0, Phenomenex). ..

    Article Title: A Comparative Study of Brassica Sprout Extracts on Intestinal Inflammation and Epithelial Barrier Integrity.
    Article Snippet: Mass spectrometric analysis was performed using a TripleQuadTM 3500 system (AB Sciex, Foster City, CA, USA). .. Chromatographic separation was achieved using a Synergi 4 μm Hydro-RP 80 A LC Column 150 × 4.6 mm (Phenomenex, Torrance, CA, USA). ..

    Injection:

    Article Title: Improving wastewater-pulse detection in karst groundwater: Integrating online monitoring with chemical and microbiological indicators
    Article Snippet: In short, 1 mL of the water sample was mixed with 20 μL of internal standard and centrifuged at 10, 000 rpm and 8 ◦C for 10 min (IKA mini-G). .. For the analysis, OMPs were separated by chromatography using a C18 column (Phenomenex Synergi 4 μm Fusion-RP, 80 Å LC Column, 50 × 2 mm) with a flow rate of 0.40 mL/min, a temperature of 50 ◦C, and an injection volume of 50 μL. ..

    Article Title: High resolution NMR and mass spectrometry to evaluate the metabolome of novel strawberry advanced breeding selections and correlate it with the fruit quality.
    Article Snippet: Vitamin C was quantified by HPLC-DAD (Agilent 1200 System, Agilent Technologies Milan, Italy) according to Helsper et al. (2003), with slight modifications. .. A Synergi 4u Fusion-RP 80A (Column 250 × 4.6 mm, Phenomenex Inc., Bologna, Italy), at a flow rate of 0.5 mL/min and an injection volume of 20 μL. ..



    Similar Products

    99
    Shimadzu Corporation reversed phase hplc method
    Reversed Phase Hplc Method, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Nexera+Series/pm42831666-123-6-9
    Average 99 stars, based on 1 article reviews
    reversed phase hplc method - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    95
    Danaher Inc synergi
    Synergi, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/pm42883601-106-6-18
    Average 95 stars, based on 1 article reviews
    synergi - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Danaher Inc synergi fusion rp column
    A. Development of an optimized bioinert LC-MS/MS workflow for modified nucleoside analysis. Comparison of the reference (left) and optimized (right) workflows, highlighting the replacement of the conventional LC column and mobile phase with a Synergy Hydro-RP bioinert column and optimized mobile-phase composition. Common analytical steps include autosampling, chromatographic separation, ionization, and MS/MS detection. B. Comparison of nucleoside retention times obtained using the reference method (5 mM ammonium acetate, <t>Synergi</t> <t>Fusion-RP</t> column) and the new method (0.5% acetic acid, Synergi Hydro-RP column). The dashed line represents the line of identity (y = x). C. Comparison of fold-change values obtained using the new method relative to the reference method for canonical nucleosides. Fold-change values were calculated relative to the reference method, which was set to 1. Data are presented as mean ± SD. D. Comparison of fold-change values obtained using the new method relative to the reference method for uridine and selected uridine-derived modifications. Fold-change values were calculated relative to the reference method, which was set to 1. Bars represent mean values, and error bars indicate SD. E. Effect of transferring the method to a bioinert LC system on nucleoside detection sensitivity. Data are presented as the ratio of peak areas obtained with the bioinert LC system (LC XSi) to those obtained with the conventional LC-40 system.
    Synergi Fusion Rp Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/bio_rxiv__64898__2026__10__13__758238-255-13-20
    Average 95 stars, based on 1 article reviews
    synergi fusion rp column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Danaher Inc synergi hydro rp column
    A. Development of an optimized bioinert LC-MS/MS workflow for modified nucleoside analysis. Comparison of the reference (left) and optimized (right) workflows, highlighting the replacement of the conventional LC column and mobile phase with a Synergy Hydro-RP bioinert column and optimized mobile-phase composition. Common analytical steps include autosampling, chromatographic separation, ionization, and MS/MS detection. B. Comparison of nucleoside retention times obtained using the reference method (5 mM ammonium acetate, <t>Synergi</t> <t>Fusion-RP</t> column) and the new method (0.5% acetic acid, Synergi Hydro-RP column). The dashed line represents the line of identity (y = x). C. Comparison of fold-change values obtained using the new method relative to the reference method for canonical nucleosides. Fold-change values were calculated relative to the reference method, which was set to 1. Data are presented as mean ± SD. D. Comparison of fold-change values obtained using the new method relative to the reference method for uridine and selected uridine-derived modifications. Fold-change values were calculated relative to the reference method, which was set to 1. Bars represent mean values, and error bars indicate SD. E. Effect of transferring the method to a bioinert LC system on nucleoside detection sensitivity. Data are presented as the ratio of peak areas obtained with the bioinert LC system (LC XSi) to those obtained with the conventional LC-40 system.
    Synergi Hydro Rp Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/bio_rxiv__64898__2026__10__15__759338-224-6-17
    Average 95 stars, based on 1 article reviews
    synergi hydro rp column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Agilent technologies hplc method
    <t>HPLC</t> chromatogram of the aqueous extract of Entandrophragma cylindricum showing absorbance (mAU) as a function of retention time (see ).
    Hplc Method, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Bio+LC/pmc13694897-187-0-2
    Average 95 stars, based on 1 article reviews
    hplc method - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Danaher Inc c18 column
    <t>HPLC</t> chromatogram of the aqueous extract of Entandrophragma cylindricum showing absorbance (mAU) as a function of retention time (see ).
    C18 Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/10__1016_slash_j__wroa__2026__100626-108-10-12
    Average 95 stars, based on 1 article reviews
    c18 column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Danaher Inc 80a column
    <t>HPLC</t> chromatogram of the aqueous extract of Entandrophragma cylindricum showing absorbance (mAU) as a function of retention time (see ).
    80a Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/pm42854910-341-20-22
    Average 95 stars, based on 1 article reviews
    80a column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Danaher Inc phenomenex synergi fusion rp column
    <t>HPLC</t> chromatogram of the aqueous extract of Entandrophragma cylindricum showing absorbance (mAU) as a function of retention time (see ).
    Phenomenex Synergi Fusion Rp Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+method/Synergi+Method+Development+HPLC+Columns/10__1016_slash_j__jfca__2026__109615-70-6-6
    Average 95 stars, based on 1 article reviews
    phenomenex synergi fusion rp column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    Image Search Results


    A. Development of an optimized bioinert LC-MS/MS workflow for modified nucleoside analysis. Comparison of the reference (left) and optimized (right) workflows, highlighting the replacement of the conventional LC column and mobile phase with a Synergy Hydro-RP bioinert column and optimized mobile-phase composition. Common analytical steps include autosampling, chromatographic separation, ionization, and MS/MS detection. B. Comparison of nucleoside retention times obtained using the reference method (5 mM ammonium acetate, Synergi Fusion-RP column) and the new method (0.5% acetic acid, Synergi Hydro-RP column). The dashed line represents the line of identity (y = x). C. Comparison of fold-change values obtained using the new method relative to the reference method for canonical nucleosides. Fold-change values were calculated relative to the reference method, which was set to 1. Data are presented as mean ± SD. D. Comparison of fold-change values obtained using the new method relative to the reference method for uridine and selected uridine-derived modifications. Fold-change values were calculated relative to the reference method, which was set to 1. Bars represent mean values, and error bars indicate SD. E. Effect of transferring the method to a bioinert LC system on nucleoside detection sensitivity. Data are presented as the ratio of peak areas obtained with the bioinert LC system (LC XSi) to those obtained with the conventional LC-40 system.

    Journal: bioRxiv

    Article Title: SPEAR: Spatial Epitranscriptomic Analysis by Mass Spectrometry Reveals Localized RNA Modification Remodeling During Glioma Progression

    doi: 10.64898/2026.10.13.758238

    Figure Lengend Snippet: A. Development of an optimized bioinert LC-MS/MS workflow for modified nucleoside analysis. Comparison of the reference (left) and optimized (right) workflows, highlighting the replacement of the conventional LC column and mobile phase with a Synergy Hydro-RP bioinert column and optimized mobile-phase composition. Common analytical steps include autosampling, chromatographic separation, ionization, and MS/MS detection. B. Comparison of nucleoside retention times obtained using the reference method (5 mM ammonium acetate, Synergi Fusion-RP column) and the new method (0.5% acetic acid, Synergi Hydro-RP column). The dashed line represents the line of identity (y = x). C. Comparison of fold-change values obtained using the new method relative to the reference method for canonical nucleosides. Fold-change values were calculated relative to the reference method, which was set to 1. Data are presented as mean ± SD. D. Comparison of fold-change values obtained using the new method relative to the reference method for uridine and selected uridine-derived modifications. Fold-change values were calculated relative to the reference method, which was set to 1. Bars represent mean values, and error bars indicate SD. E. Effect of transferring the method to a bioinert LC system on nucleoside detection sensitivity. Data are presented as the ratio of peak areas obtained with the bioinert LC system (LC XSi) to those obtained with the conventional LC-40 system.

    Article Snippet: The reference method was performed on a Nexera LC-40 system equipped with a Synergi Fusion-RP column (250×2mm, 4μm, 80A, 00G-4424-B0, Phenomenex).

    Techniques: Liquid Chromatography with Mass Spectroscopy, Modification, Analysis, Comparison, Tandem Mass Spectroscopy, Derivative Assay, Transferring, Sensitivity

    HPLC chromatogram of the aqueous extract of Entandrophragma cylindricum showing absorbance (mAU) as a function of retention time (see ).

    Journal: IBRO Neuroscience Reports

    Article Title: Neuroprotective effects of Entandrophragma cylindricum (Meliaceae) extract against “Odontol’’-induced cognitive and depressive disorders: An integrated HPLC, molecular docking and experimental validation

    doi: 10.1016/j.ibneur.2026.09.019

    Figure Lengend Snippet: HPLC chromatogram of the aqueous extract of Entandrophragma cylindricum showing absorbance (mAU) as a function of retention time (see ).

    Article Snippet: HPLC method (Agilent Chemstation 1260 infinity.

    Techniques: