Review




Structured Review

Aushon Biosystems 2470-microarray printer
2470 Microarray Printer, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/2470+microarrayer/pmc10076948-31-12-14
Average 90 stars, based on 1 article reviews
2470-microarray printer - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Microarray:

Article Title: RAC1 P29S Induces a Mesenchymal Phenotypic Switch via Serum Response Factor to Promote Melanoma Development and Therapy Resistance.
Article Snippet: .. In brief, lysates were serially diluted, arrayed on slides with a 2470 Microarray Printer (Aushon Biosystems) and probed with 300 validated (phospho-)antibodies and biotinylated secondary antibodies. ..

Article Title: A Read/Write Mechanism Connects p300 Bromodomain Function to H2A.Z Acetylation
Article Snippet: Histone peptide microarrays were fabricated by depositing biotinylated histone peptides onto streptavidin-coated glass microscope slides using an Aushon 2470 microarray printer. .. Briefly, biotinylated peptides were deposited onto streptavidin-coated glass microscope slides using an Aushon 2470 microarray printer. ..

Article Title: MCU controls melanoma progression through a redox‐controlled phenotype switch
Article Snippet: .. Shortly, serial‐diluted lysates were printed on nitrocellulose‐coated slides using a 2470 Microarray printer from Aushon Biosystems (Billerica, Massachusetts, USA). ..

Article Title: MCU controls melanoma progression through a redox-controlled phenotype switch.
Article Snippet: Melanoma is the deadliest of skin cancers and has a high tendency to metastasize to distant organs.. Calcium and metabolic signals contribute to melanoma invasiveness; however, the underlying molecular details are elusive.. The MCU complex is a major route for calcium into the mitochondrial matrix but whether MCU affects melanoma pathobiology was not understood.

Microscopy:

Article Title: A Read/Write Mechanism Connects p300 Bromodomain Function to H2A.Z Acetylation
Article Snippet: Histone peptide microarrays were fabricated by depositing biotinylated histone peptides onto streptavidin-coated glass microscope slides using an Aushon 2470 microarray printer. .. Briefly, biotinylated peptides were deposited onto streptavidin-coated glass microscope slides using an Aushon 2470 microarray printer. ..

other:

Article Title: A distinct pattern of growth and RAC1 signaling in melanoma brain metastasis cells
Article Snippet: Briefly, cell lysates (and controls) were printed on nitrocellulose-coated slides using a 2470-Microarray printer (Aushon Biosystems, Billerica, USA).



Similar Products

90
Quanterix 2470 arrayer high-throughput microarray printing equipment
2470 Arrayer High Throughput Microarray Printing Equipment, supplied by Quanterix, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/2470+arrayer/ppr0652443-65-51-56
Average 90 stars, based on 1 article reviews
2470 arrayer high-throughput microarray printing equipment - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Aushon Biosystems 2470-microarray printer
2470 Microarray Printer, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/2470+microarrayer/pmc10076948-31-12-14
Average 90 stars, based on 1 article reviews
2470-microarray printer - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Aushon Biosystems 2470 microarray printer
2470 Microarray Printer, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/2470+microarrayer/pm36156348-441-10-14
Average 90 stars, based on 1 article reviews
2470 microarray printer - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Aushon Biosystems 2470 microarray robot
Protein <t>microarray</t> data indicate that phosphorylation of S298 in maCx35 may act as a functional switch. ( a ) Membrane topology of connexins. N- and C-terminal tails (NT and CT, respectively) and the cytoplasmic loop (CL) reside inside the cytoplasm. The two extracellular loops (EL) are also indicated. ( b ) Sequence of the C-terminal end of maCx35/mmCx36, as indicated by the box in ( a ). Sequence identity (*) is high for mmCx36 and maCx35 at the C-terminal end. The blue box indicates a PKA/CaMKII consensus site at position S315 and S298 for mmCx36 and maCx35, respectively. The last four amino acids represent a PDZ binding domain, present in both proteins. ( c ) Microarray layout (A-D); the respective baits (all fused to GST) are found below. An array probed with Alexa Fluor 555 anti-GST antibody served as positive control. Peptides fused to biotin containing the C-terminal tail of maCx35 (35 WT), phosphorylated maCx35 (35 S298 phos), and a truncated version (35 S298 ter) were used as probes and showed differential results, marked by rounded squares. 14–3–3 proteins (red) and NHERF2 aa265-288 (blue D7) showed an increased binding to the 35 S298 phospho probe compared to 35 WT. In contrast, PDZK1, PDZ10 of MUPP1, and nNOS (blue) decreased their binding to the 35 S298 phospho probe. The truncated 35 S298 ter probe showed no binding interactions.
2470 Microarray Robot, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/2470+microarray+robot/pmc07592057-162-21-20
Average 90 stars, based on 1 article reviews
2470 microarray robot - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Aushon Biosystems forward-phase protein microarray platforms aushon 2470
Protein <t>microarray</t> data indicate that phosphorylation of S298 in maCx35 may act as a functional switch. ( a ) Membrane topology of connexins. N- and C-terminal tails (NT and CT, respectively) and the cytoplasmic loop (CL) reside inside the cytoplasm. The two extracellular loops (EL) are also indicated. ( b ) Sequence of the C-terminal end of maCx35/mmCx36, as indicated by the box in ( a ). Sequence identity (*) is high for mmCx36 and maCx35 at the C-terminal end. The blue box indicates a PKA/CaMKII consensus site at position S315 and S298 for mmCx36 and maCx35, respectively. The last four amino acids represent a PDZ binding domain, present in both proteins. ( c ) Microarray layout (A-D); the respective baits (all fused to GST) are found below. An array probed with Alexa Fluor 555 anti-GST antibody served as positive control. Peptides fused to biotin containing the C-terminal tail of maCx35 (35 WT), phosphorylated maCx35 (35 S298 phos), and a truncated version (35 S298 ter) were used as probes and showed differential results, marked by rounded squares. 14–3–3 proteins (red) and NHERF2 aa265-288 (blue D7) showed an increased binding to the 35 S298 phospho probe compared to 35 WT. In contrast, PDZK1, PDZ10 of MUPP1, and nNOS (blue) decreased their binding to the 35 S298 phospho probe. The truncated 35 S298 ter probe showed no binding interactions.
Forward Phase Protein Microarray Platforms Aushon 2470, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/solid+pin+protein+microarrayer+aushon+2470/pm30784367-76-8-12
Average 90 stars, based on 1 article reviews
forward-phase protein microarray platforms aushon 2470 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Aushon Biosystems microarray printer aushon 2470
Protein <t>microarray</t> data indicate that phosphorylation of S298 in maCx35 may act as a functional switch. ( a ) Membrane topology of connexins. N- and C-terminal tails (NT and CT, respectively) and the cytoplasmic loop (CL) reside inside the cytoplasm. The two extracellular loops (EL) are also indicated. ( b ) Sequence of the C-terminal end of maCx35/mmCx36, as indicated by the box in ( a ). Sequence identity (*) is high for mmCx36 and maCx35 at the C-terminal end. The blue box indicates a PKA/CaMKII consensus site at position S315 and S298 for mmCx36 and maCx35, respectively. The last four amino acids represent a PDZ binding domain, present in both proteins. ( c ) Microarray layout (A-D); the respective baits (all fused to GST) are found below. An array probed with Alexa Fluor 555 anti-GST antibody served as positive control. Peptides fused to biotin containing the C-terminal tail of maCx35 (35 WT), phosphorylated maCx35 (35 S298 phos), and a truncated version (35 S298 ter) were used as probes and showed differential results, marked by rounded squares. 14–3–3 proteins (red) and NHERF2 aa265-288 (blue D7) showed an increased binding to the 35 S298 phospho probe compared to 35 WT. In contrast, PDZK1, PDZ10 of MUPP1, and nNOS (blue) decreased their binding to the 35 S298 phospho probe. The truncated 35 S298 ter probe showed no binding interactions.
Microarray Printer Aushon 2470, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/microarrayer+2470+arrayer/pmc06889796__mmc1-82-17-17
Average 90 stars, based on 1 article reviews
microarray printer aushon 2470 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Aushon Biosystems contact microarray printer aushon 2470
Materials
Contact Microarray Printer Aushon 2470, supplied by Aushon Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2470+microarray/microarrayer+2470+arrayer/pmc05613814-5-9-8
Average 90 stars, based on 1 article reviews
contact microarray printer aushon 2470 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Protein microarray data indicate that phosphorylation of S298 in maCx35 may act as a functional switch. ( a ) Membrane topology of connexins. N- and C-terminal tails (NT and CT, respectively) and the cytoplasmic loop (CL) reside inside the cytoplasm. The two extracellular loops (EL) are also indicated. ( b ) Sequence of the C-terminal end of maCx35/mmCx36, as indicated by the box in ( a ). Sequence identity (*) is high for mmCx36 and maCx35 at the C-terminal end. The blue box indicates a PKA/CaMKII consensus site at position S315 and S298 for mmCx36 and maCx35, respectively. The last four amino acids represent a PDZ binding domain, present in both proteins. ( c ) Microarray layout (A-D); the respective baits (all fused to GST) are found below. An array probed with Alexa Fluor 555 anti-GST antibody served as positive control. Peptides fused to biotin containing the C-terminal tail of maCx35 (35 WT), phosphorylated maCx35 (35 S298 phos), and a truncated version (35 S298 ter) were used as probes and showed differential results, marked by rounded squares. 14–3–3 proteins (red) and NHERF2 aa265-288 (blue D7) showed an increased binding to the 35 S298 phospho probe compared to 35 WT. In contrast, PDZK1, PDZ10 of MUPP1, and nNOS (blue) decreased their binding to the 35 S298 phospho probe. The truncated 35 S298 ter probe showed no binding interactions.

Journal: Scientific Reports

Article Title: Phosphorylation of Connexin36 near the C-terminus switches binding affinities for PDZ-domain and 14–3–3 proteins in vitro

doi: 10.1038/s41598-020-75375-0

Figure Lengend Snippet: Protein microarray data indicate that phosphorylation of S298 in maCx35 may act as a functional switch. ( a ) Membrane topology of connexins. N- and C-terminal tails (NT and CT, respectively) and the cytoplasmic loop (CL) reside inside the cytoplasm. The two extracellular loops (EL) are also indicated. ( b ) Sequence of the C-terminal end of maCx35/mmCx36, as indicated by the box in ( a ). Sequence identity (*) is high for mmCx36 and maCx35 at the C-terminal end. The blue box indicates a PKA/CaMKII consensus site at position S315 and S298 for mmCx36 and maCx35, respectively. The last four amino acids represent a PDZ binding domain, present in both proteins. ( c ) Microarray layout (A-D); the respective baits (all fused to GST) are found below. An array probed with Alexa Fluor 555 anti-GST antibody served as positive control. Peptides fused to biotin containing the C-terminal tail of maCx35 (35 WT), phosphorylated maCx35 (35 S298 phos), and a truncated version (35 S298 ter) were used as probes and showed differential results, marked by rounded squares. 14–3–3 proteins (red) and NHERF2 aa265-288 (blue D7) showed an increased binding to the 35 S298 phospho probe compared to 35 WT. In contrast, PDZK1, PDZ10 of MUPP1, and nNOS (blue) decreased their binding to the 35 S298 phospho probe. The truncated 35 S298 ter probe showed no binding interactions.

Article Snippet: Purified GST fusion proteins (listed in Fig. c and Supplementary Fig. ) were spotted onto nitrocellulose-coated glass slides with an Aushon 2470 microarray robot; each protein was spotted in duplicate.

Techniques: Microarray, Functional Assay, Sequencing, Binding Assay, Positive Control

Materials

Journal: Journal of visualized experiments : JoVE

Article Title: Analysis of Histone Antibody Specificity with Peptide Microarrays

doi: 10.3791/55912

Figure Lengend Snippet: Materials

Article Snippet: contact microarray printer , Aushon , 2470 , Aushon 2470 Microarray Printer.

Techniques: Microscopy, Microarray, Blocking Assay, Plasmid Preparation, Hybridization, Peptide Microarray, Modification, High Throughput Screening Assay

A screen shot of the ArrayNinja design module is shown in the dotted line. The control panel (top) shows all of the parameters that can be altered on the microarray printer. As these parameters are adjusted, the cartoon image of the slide layout (bottom left) updates in real time. After the layout is set, the user can mouse over individual spots to enter unique feature identifiers. ArrayNinja constructs from this user input a map of the position of each feature in the source plate(s) (bottom right) needed to fabricate a specified microarray slide layout.

Journal: Journal of visualized experiments : JoVE

Article Title: Analysis of Histone Antibody Specificity with Peptide Microarrays

doi: 10.3791/55912

Figure Lengend Snippet: A screen shot of the ArrayNinja design module is shown in the dotted line. The control panel (top) shows all of the parameters that can be altered on the microarray printer. As these parameters are adjusted, the cartoon image of the slide layout (bottom left) updates in real time. After the layout is set, the user can mouse over individual spots to enter unique feature identifiers. ArrayNinja constructs from this user input a map of the position of each feature in the source plate(s) (bottom right) needed to fabricate a specified microarray slide layout.

Article Snippet: contact microarray printer , Aushon , 2470 , Aushon 2470 Microarray Printer.

Techniques: Microarray, Construct

(A) Histone peptide microarray fabrication on streptavidin-coated microscope slides using a contact microarray printer. (B) Microarrays fabricated with 3 subarrays of a 48 × 48 grid of peptide features. Separation of (C) 3 subarrays with a hydrophobic wax pen, (D) 2 subarrays with a silicon adhesive, and (E) 48 subarrays with a wax imprint. All microarrays shown are fabricated using 25 × 75 mm microscope slides.

Journal: Journal of visualized experiments : JoVE

Article Title: Analysis of Histone Antibody Specificity with Peptide Microarrays

doi: 10.3791/55912

Figure Lengend Snippet: (A) Histone peptide microarray fabrication on streptavidin-coated microscope slides using a contact microarray printer. (B) Microarrays fabricated with 3 subarrays of a 48 × 48 grid of peptide features. Separation of (C) 3 subarrays with a hydrophobic wax pen, (D) 2 subarrays with a silicon adhesive, and (E) 48 subarrays with a wax imprint. All microarrays shown are fabricated using 25 × 75 mm microscope slides.

Article Snippet: contact microarray printer , Aushon , 2470 , Aushon 2470 Microarray Printer.

Techniques: Peptide Microarray, Microscopy, Microarray