Review




Structured Review

Spectranetics quickcat
Quickcat, supplied by Spectranetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/quickcat/quickcat/pmc11547099-247-7-9
Average 90 stars, based on 1 article reviews
quickcat - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Thrombus aspiration in primary angioplasty for ST-segment elevation myocardial infarction.
Article Snippet: Mechanical reperfusion with primary percutaneous coronary intervention in acute ST-segment-elevation myocardial infarction is superior to fibrinolysis in terms of short-term and long-term outcome, provided that it can be delivered on time and by an experienced team.. Balloon angioplasty and stent implantation of an occluded epicardial vessel during ST-segmentelevation myocardial infarction can cause disruption of the frail thrombus containing lesions associated with suboptimal myocardial reperfusion and microcirculatory obstruction.. Distal embolization of atherothrombotic material can be prevented by thrombus aspiration during primary angioplasty.

Article Title: Outcomes From Selective Use of Thrombectomy in Patients Undergoing Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction: An Analysis of the British Cardiovascular Intervention Society/National Institute for Cardiovascular Outcomes Research (BCIS-NICOR) Registry, 2006-2013.
Article Snippet: Simple (manual) thrombectomy procedures were those that involved any of the following (aspiration) devices: Pronto (Vascular Solutions Inc., Minneapolis, Minnesota), Hunter (IHT Cordynamic, Barcelona, Spain), Eliminate (Terumo Europe, Leuven, Belgium), Export (Medtronic, Minneapolis, Minnesota), Quickcat (Spectranetics Inc., Colorado Springs, Colorado), Thrombcat (Kensay Nash Corp., Exton, Pennsylvania), and Diver (Invatec, Roncadelle, Italy).

Article Title: Localization of Hemostasis Elements in Aspirated Coronary Thrombi at Different Stages of Evolution
Article Snippet: Two different thrombus aspiration systems were used: QuickCat (The Spectranetics Corporation/Philips Healthcare, Colorado Springs, CO, USA) and ASAP (Merit Medical Systems, Inc., South Jordan, UT, USA).

Article Title: Ultrastructure and composition of thrombi in coronary and peripheral artery disease: correlations with clinical and laboratory findings.
Article Snippet: a Department of Medical Biochemistry, Semmelweis University, Budapest, Hungary b Heart and Vascular Center, Semmelweis University, Budapest, Hungary c Department of Information Technology, Nikola Vaptsarov Naval Academy, Varna, Bulgaria d Australian Maritime College, University of Tasmania, Launceston, Australia e Institute of Materials and Environmental Chemistry, Research Centre for Natural Sciences, Hungarian Academy of Sciences, Budapest, Hungary f 1 Department of Pathology and Experimental Cancer Research, Semmelweis University, Budapest, Hungary

Article Title: Manual Thrombus Aspiration Is Not Associated With Reduced Mortality in Patients Treated With Primary Percutaneous Coronary Intervention: An Observational Study of 10,929 Patients With ST-Segment Elevation Myocardial Infarction From the London Heart Attack Group.
Article Snippet: All thrombus aspiration was performed manually using the following devices: Export (Medtronic, Minneapolis, Minnesota) in 67.4%; X-Sizer (ev3, Plymouth, Minnesota) in 3.9%; Pronto (Vascular Solutions, Minneapolis, Minnesota) in 2.9%; TEC (Boston Scientific, Natick, Massachusetts) in 6.4%; and others including Hunter (Innovative Health Technologies), QuickCat (Spectranetics, Colorado Springs, Colorado), Eliminate (Terumo, Somerset, New Jersey), and Rescue (Boston Scientific) in 19.4%.

Article Title: Thrombus aspiration during primary percutaneous coronary intervention for acute myocardial infarction: A review of clinical evidence and guidelines
Article Snippet: The commonly used aspiration devices in clinical practice are Export ® (Medtronic, MN, United States), EliminateTM (Terumo), ProntoTM (Vascular solutions, MN, United States) DiverTM CE (Invatec, Italy), QuickCat (Spectranetics Inc, United States) and Hunter ® (IHT Cordynamic, Barcelona, Spain).

Article Title: Thrombus Aspiration in STEMI.
Article Snippet: ST-segment elevation myocardial infarction (STEMI) remains an important cause of morbidity and mortality.. In the USA, the development of an organized STEMI network has allowed STEMI patients greater access to primary PCI.. The most important goal in the management of STEMI is timely reperfusion and establishment of normal coronary flow.

Article Title: Thrombus Aspiration for ST-Segment–Elevation Myocardial Infarction in Modern Era
Article Snippet: Therefore, the mechanical TA catheter is rarely used nowadays.6,24 The commonly used manual TA devices in clinical practice are Export AP (Medtronic), Eliminate (Terumo, Japan), Fetch 2 (Bayer Healthcare, the Netherlands), ZEEK (Zeon Medical, Japan), Diver CE (Invatec, Italy), QuickCat (Spectranetics), and Pronto (Vascular solutions, MN).



Similar Products

90
Philips Healthcare quickcat
Specifications most commonly used thrombectomy aspiration catheters in 2018 ( <xref ref-type= 1 – 3 )." width="250" height="auto" />
Quickcat, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/quickcat/quickcat/pmc11625537-58-19-24
Average 90 stars, based on 1 article reviews
quickcat - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Spectranetics quickcat
Specifications most commonly used thrombectomy aspiration catheters in 2018 ( <xref ref-type= 1 – 3 )." width="250" height="auto" />
Quickcat, supplied by Spectranetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/quickcat/quickcat/pmc11547099-247-7-9
Average 90 stars, based on 1 article reviews
quickcat - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Spectranetics quickcat extraction catheter
Specifications most commonly used thrombectomy aspiration catheters in 2018 ( <xref ref-type= 1 – 3 )." width="250" height="auto" />
Quickcat Extraction Catheter, supplied by Spectranetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/quickcat/quickcat+extraction+catheter/pmc06146079-434-59-62
Average 90 stars, based on 1 article reviews
quickcat extraction catheter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Spectranetics extraction catheter quickcat
Specifications most commonly used thrombectomy aspiration catheters in 2018 ( <xref ref-type= 1 – 3 )." width="250" height="auto" />
Extraction Catheter Quickcat, supplied by Spectranetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/quickcat/quickcat+extraction+catheter/pmc06718363-58-4-7
Average 90 stars, based on 1 article reviews
extraction catheter quickcat - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Specifications most commonly used thrombectomy aspiration catheters in 2018 ( <xref ref-type= 1 – 3 )." width="100%" height="100%">

Journal: Frontiers in Medical Technology

Article Title: Advancements in aspiration catheter tip design for thrombectomy: a comprehensive patent review

doi: 10.3389/fmedt.2024.1388638

Figure Lengend Snippet: Specifications most commonly used thrombectomy aspiration catheters in 2018 ( 1 – 3 ).

Article Snippet: The three most commonly used thrombectomy aspiration catheters are Export XT from Medtronic, Pronto V3 from Vascular Solutions, and QuickCat from Volcano Therapeutics (currently Philips) ( – ).

Techniques: Extraction

Similar features between the state-of-the-art thrombectomy catheters (A: export XT, B: pronto V3, and C:  quickCat)  and selected patents with corresponding categories.

Journal: Frontiers in Medical Technology

Article Title: Advancements in aspiration catheter tip design for thrombectomy: a comprehensive patent review

doi: 10.3389/fmedt.2024.1388638

Figure Lengend Snippet: Similar features between the state-of-the-art thrombectomy catheters (A: export XT, B: pronto V3, and C: quickCat) and selected patents with corresponding categories.

Article Snippet: The three most commonly used thrombectomy aspiration catheters are Export XT from Medtronic, Pronto V3 from Vascular Solutions, and QuickCat from Volcano Therapeutics (currently Philips) ( – ).

Techniques: