Review



virtual touch tissue imaging and quantification (vtiq) software  (Siemens AG)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Siemens AG virtual touch tissue imaging and quantification (vtiq) software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Imaging And Quantification (Vtiq) Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11088583-105-87-81
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography"

    Article Title: Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography

    Journal: Insights into Imaging

    doi: 10.1186/s13244-024-01695-8

    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Figure Legend Snippet: SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Techniques Used:

    Related Articles

    Software:

    Article Title: Laryngeal and pleural ultrasound and acoustic radiation force impulse elastography in dogs with brachycephalic obstructive airway syndrome.
    Article Snippet: .. ARFI elastography was performed using the Virtual Touch Tissue Quantification software (Siemens, Germany), which, once activated on the B-mode ultrasound image, creates an elastogram. .. ARFI elastography was performed using the Virtual Touch Tissue Quantification software (Siemens, Germany), which, once activated on the B-mode ultrasound image, creates an elastogram.

    Article Title: Evaluation of ARFI elastography for detecting active mastitis in sheep with previous fibrous lesions: a study of mammary parenchyma and supramammary lymph nodes
    Article Snippet: .. Following the B-mode evaluation, ARFI elastography was conducted utilizing the Virtual Touch Tissue QuantificationTM software (Siemens, Germany) on the breast parenchyma and supramammary lymph nodes. ..

    Article Title: Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography
    Article Snippet: .. The entire tendon was scanned, capturing the area with the highest neovessel density. a Baseline long-axis US with Power Doppler imaging reveals pixels of Doppler signal covering around 50% of the tendon surface, indicating Grade 2 neovascularity. b Following tendon fenestration treatment, the 6-month follow-up long-axis US displays partial neovessel regression, with a few pixels of Doppler signal indicating Grade 1 neovascularity. c The 12-month follow-up long-axis US exhibits a nearly complete resolution of the Doppler signal (Grade 1 neovascularity) Using Siemens’s virtual touch tissue imaging and quantification (VTIQ) software, we assessed SWV on a long-axis image depicting the minor groove at the base of the lateral humeral epicondyle. ..

    other:

    Article Title: Modern ultrasound techniques for diagnosing liver steatosis and fibrosis: A systematic review with a focus on biopsy comparison
    Article Snippet: Atzori et al [ ] evaluated the accuracy of the following three SWE methods: Philips Elast point quantification, Siemens Virtual Touch TM Quantification (VTQ) acoustic radiation force impulse, and transient elastography (TE) measured using the Echosens FibroScan in a cohort of 160 patients in 2024.

    Article Title: Quantitative studies on B-mode ultrasound and point shear wave elastography of kidneys in nonazotemic dogs.
    Article Snippet: Correspondence Biswadeep Jena, Department of Veterinary Surgery and Radiology, College of Veterinary Sciences, Guru AngadDev Veterinary and Animal Sciences University, Ludhiana, Punjab, 141 004, India.. Email: biswadeep44@gmail.com Abstract Renal diseases in dogs can be diagnosed effectively using B-mode ultrasound.. Point shear wave elastography (pSWE) has demonstrated usefulness in diagnosing renal diseases in human medicine.

    Article Title: Liver disease
    Article Snippet: In one aspect, pSWE (Elastography point quantification, ElastPQTM, Phillips) or ARFI imaging (Virtual touch tissue QuantificationTM, Siemens) is (ultrasound-based elastography techniques) used to assess liver stiffness.

    Comparison:

    Article Title: Role of 2D shear wave elastography in assessing chronic kidney disease and its correlation with point shear wave elastography and eGFR.
    Article Snippet: The study was conducted with the aim of calculating renal stiffness through shear wave sonoelastography (SWE) in chronic kidney disease (CKD) and in normal kidneys, to find out a cut off value to differentiate between the two.. This cross-sectional study included 80 participants (40 CKD patients and 40 subjects with normal renal function) with eGFR calculated using serum creatinine taken as a biochemical parameter.. All participants underwent 2D and point SWE.

    Control:

    Article Title: Role of 2D shear wave elastography in assessing chronic kidney disease and its correlation with point shear wave elastography and eGFR.
    Article Snippet: The study was conducted with the aim of calculating renal stiffness through shear wave sonoelastography (SWE) in chronic kidney disease (CKD) and in normal kidneys, to find out a cut off value to differentiate between the two.. This cross-sectional study included 80 participants (40 CKD patients and 40 subjects with normal renal function) with eGFR calculated using serum creatinine taken as a biochemical parameter.. All participants underwent 2D and point SWE.

    Shear:

    Article Title: Role of 2D shear wave elastography in assessing chronic kidney disease and its correlation with point shear wave elastography and eGFR.
    Article Snippet: The study was conducted with the aim of calculating renal stiffness through shear wave sonoelastography (SWE) in chronic kidney disease (CKD) and in normal kidneys, to find out a cut off value to differentiate between the two.. This cross-sectional study included 80 participants (40 CKD patients and 40 subjects with normal renal function) with eGFR calculated using serum creatinine taken as a biochemical parameter.. All participants underwent 2D and point SWE.

    Article Title: The Effect of Steatosis on Shear-Wave Velocity and Viscoelastic Properties Related to Liver Fibrosis Progression in Rat Models.
    Article Snippet: Objective: Hepatic fibrosis has recently been evaluated using ultrasonography or magnetic resonance elastography.. Although the shear wave velocity (SWV) obtained using point shear wave elastography (pSWE) provides a valuable measure of fibrosis, underlying steatosis may affect its measurement.. Methods: Using hepatic fibrosis samples, this study evaluated the effect of steatosis on the shear wave velocity of pSWE (Vs) and viscoelastic properties (assessed by dynamic mechanical analysis) of rat liver.

    Imaging:

    Article Title: Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography
    Article Snippet: .. The entire tendon was scanned, capturing the area with the highest neovessel density. a Baseline long-axis US with Power Doppler imaging reveals pixels of Doppler signal covering around 50% of the tendon surface, indicating Grade 2 neovascularity. b Following tendon fenestration treatment, the 6-month follow-up long-axis US displays partial neovessel regression, with a few pixels of Doppler signal indicating Grade 1 neovascularity. c The 12-month follow-up long-axis US exhibits a nearly complete resolution of the Doppler signal (Grade 1 neovascularity) Using Siemens’s virtual touch tissue imaging and quantification (VTIQ) software, we assessed SWV on a long-axis image depicting the minor groove at the base of the lateral humeral epicondyle. ..



    Similar Products

    90
    Siemens AG virtual touch tissue quantification software
    Virtual Touch Tissue Quantification Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm40481134-150-6-11
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue imaging and quantification software
    Virtual Touch Tissue Imaging And Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm39842258-51-25-27
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue imaging quantification (vtiq) software
    Virtual Touch Tissue Imaging Quantification (Vtiq) Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11306866-94-14-25
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens AG virtual touch tissue imaging and quantification (vtiq) software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Imaging And Quantification (Vtiq) Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11088583-105-87-81
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue quantification software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc09009350-79-7-12
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Quantification (Vtq) Software With A 6c1 Hd Convex Probe, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc08446499-84-17-9
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Journal: Insights into Imaging

    Article Title: Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography

    doi: 10.1186/s13244-024-01695-8

    Figure Lengend Snippet: SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Article Snippet: The entire tendon was scanned, capturing the area with the highest neovessel density. a Baseline long-axis US with Power Doppler imaging reveals pixels of Doppler signal covering around 50% of the tendon surface, indicating Grade 2 neovascularity. b Following tendon fenestration treatment, the 6-month follow-up long-axis US displays partial neovessel regression, with a few pixels of Doppler signal indicating Grade 1 neovascularity. c The 12-month follow-up long-axis US exhibits a nearly complete resolution of the Doppler signal (Grade 1 neovascularity) Using Siemens’s virtual touch tissue imaging and quantification (VTIQ) software, we assessed SWV on a long-axis image depicting the minor groove at the base of the lateral humeral epicondyle.

    Techniques: