Review



virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe  (Siemens Healthineers)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Siemens Healthineers virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe
    Virtual Touch Tissue Quantification (Vtq) Software With A 6c1 Hd Convex Probe, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc08446499-84-17-9
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Shear-wave elastography as a supplementary tool for axillary staging in patients undergoing breast cancer diagnosis
    Article Snippet: SWE was performed using 2D-SWE systems Siemens Acuson S2000 or S3000 equipped with virtual touch tissue imaging quantification (VTIQ) software utilizing a 9 MHz probe (Siemens Healthineers).

    Article Title: Shear wave elastography as a supplemental tool in the assessment of unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination
    Article Snippet: B-mode ultrasound (US) and SWE were performed using 2D-SWE systems Siemens Acuson S2000 or S3000 equipped with virtual touch tissue imaging quantification (VTIQ) software utilizing a 9MHz probe (Siemens Healthineers).

    Article Title: Ultrasound-based quantitative tools in predicting renal involvement in asymptomatic primary hyperparathyroidism.
    Article Snippet: Radiological examinations were performed using an S3000 Acuson system (Siemens Healthcare) equipped with an ARFI function (Virtual Touch Tissue Quantification package, Siemens Healthcare, Erlangen, Germany) and a 4 to 6-MHz convex probe.

    Imaging:

    Article Title: A prospective observational study on intracranial pressure management: A comparison of three ultrasound techniques.
    Article Snippet: Objective: This prospective observational study aimed to assess the effectiveness of B-mode ultrasound, colorcoded Doppler, and shear-wave elastography in predicting intracranial pressure (ICP) and their capability to evaluate the efficacy of ICP lowering therapy.. Materials and methods: Forty-eight neuro-critical care patients were enrolled and categorized into 2 groups based on ICP measurements obtained through external ventricular drainage: the intracranial hypertension (IH) and normal ICP groups.. The optic nerve (ON) sheath diameter (ONSD), end diastolic velocity, peak systolic velocity, resistance index of the central retinal artery (CRA), and Young’s modulus (YM) of the ON were recorded after external ventricular drainage placement and following ICP lowering treatment in the IH group.

    Article Title: SuperSonic shear imaging for the differentiation between benign and malignant thyroid nodules: a meta-analysis.
    Article Snippet: Purpose To assess the diagnostic value of SuperSonic shear imaging (SSI) for the differentiation between benign and malignant thyroid nodules through meta-analysis.. Methods Online database searches were performed on PubMed, EMBASE, the Cochrane Library, and the Web of Science until 31 July 2021.. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the quality of the included studies.

    Article Title: Use of shear wave elastography to analyze the muscle structure in children with spastic cerebral palsy
    Article Snippet: .. At present, in addition to point SWE technique, a two-dimensional SWE technique called virtual touch tissue imaging and quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA, USA) has been applied and used in clinical practice. ..

    Software:

    Article Title: A prospective observational study on intracranial pressure management: A comparison of three ultrasound techniques.
    Article Snippet: Objective: This prospective observational study aimed to assess the effectiveness of B-mode ultrasound, colorcoded Doppler, and shear-wave elastography in predicting intracranial pressure (ICP) and their capability to evaluate the efficacy of ICP lowering therapy.. Materials and methods: Forty-eight neuro-critical care patients were enrolled and categorized into 2 groups based on ICP measurements obtained through external ventricular drainage: the intracranial hypertension (IH) and normal ICP groups.. The optic nerve (ON) sheath diameter (ONSD), end diastolic velocity, peak systolic velocity, resistance index of the central retinal artery (CRA), and Young’s modulus (YM) of the ON were recorded after external ventricular drainage placement and following ICP lowering treatment in the IH group.

    Shear:

    Article Title: SuperSonic shear imaging for the differentiation between benign and malignant thyroid nodules: a meta-analysis.
    Article Snippet: Purpose To assess the diagnostic value of SuperSonic shear imaging (SSI) for the differentiation between benign and malignant thyroid nodules through meta-analysis.. Methods Online database searches were performed on PubMed, EMBASE, the Cochrane Library, and the Web of Science until 31 July 2021.. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the quality of the included studies.



    Similar Products

    90
    Siemens AG virtual touch tissue quantification software
    Virtual Touch Tissue Quantification Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm40481134-150-6-11
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue imaging and quantification software
    Virtual Touch Tissue Imaging And Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm39842258-51-25-27
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue imaging quantification (vtiq) software
    Virtual Touch Tissue Imaging Quantification (Vtiq) Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11306866-94-14-25
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens AG virtual touch tissue imaging and quantification (vtiq) software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Imaging And Quantification (Vtiq) Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11088583-105-87-81
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue quantification software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc09009350-79-7-12
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Quantification (Vtq) Software With A 6c1 Hd Convex Probe, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc08446499-84-17-9
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Journal: Insights into Imaging

    Article Title: Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography

    doi: 10.1186/s13244-024-01695-8

    Figure Lengend Snippet: SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Article Snippet: The entire tendon was scanned, capturing the area with the highest neovessel density. a Baseline long-axis US with Power Doppler imaging reveals pixels of Doppler signal covering around 50% of the tendon surface, indicating Grade 2 neovascularity. b Following tendon fenestration treatment, the 6-month follow-up long-axis US displays partial neovessel regression, with a few pixels of Doppler signal indicating Grade 1 neovascularity. c The 12-month follow-up long-axis US exhibits a nearly complete resolution of the Doppler signal (Grade 1 neovascularity) Using Siemens’s virtual touch tissue imaging and quantification (VTIQ) software, we assessed SWV on a long-axis image depicting the minor groove at the base of the lateral humeral epicondyle.

    Techniques: