Review




Structured Review

Biosense Webster variable loop pfa catheter
Variable Loop Pfa Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/catheter+circular+loop+variable/pmc12618193-81-24-29
Average 86 stars, based on 1 article reviews
variable loop pfa catheter - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

other:

Article Title: Principles Guiding PFA Cardiac Catheter and Sheath Management from Preclinical Assessment of Microbubble Formation and Air Intrusion Models.
Article Snippet: 125 For the microbubble evaluations during ablations, two ablation modalities were used: 126 pulsed-field ablation (PFA) using a Variable Loop Circular Catheter (VLCC; Varipulse, 127 Biosense Webster Inc., a part of Johnson & Johnson MedTech, Irvine, CA) with the TRUPULSE 128 Generator (Biosense Webster) and focal radiofrequency (RF) ablation using the 129 THERMOCOOL SMARTTOUCH® SF catheter (Biosense Webster) with the nGENTM 130 Generator (Biosense Webster).

Article Title: Hemolysis After Pulsed Field Ablation With a Variable-Loop Irrigated Circular Catheter.
Article Snippet: Introduction: Hemolysis is a recognized complication of endocardial pulsed field ablation (PFA), and its severity is influenced by factors such as the number of applications, tissue contact, and characteristics of the PFA system.. However, most existing data are based on the Pentaspline catheter, and limited information is available regarding hemolysis with other PFA systems.. Methods and Results: We evaluated hemolysis in seven consecutive patients with paroxysmal atrial fibrillation undergoing PFA using a variable-loop irrigated circular catheter (VLCC; Varipulse, Biosense Webster) and a dedicated generator (TRUPULSE).

Article Title: Navigating the Zero Fluoroscopy Frontier: Current Tools, Evidence and Future Directions in Electrophysiology Procedures.
Article Snippet: Subsequently, with the integration of PFA systems into EAM platforms, additional case series have evaluated the pentaspline Farawave (Boston Scientific), the fixedloop circular Pulselect (Medtronic), and the variable-loop circular Varipulse (Biosense Webster) catheters and collectively show that such systems can be successfully combined with EAM, ICE and visualized sheath, resulting in substantial reductions in radiation exposure while maintaining procedural safety and efficacy [ 72–78 ].

Article Title: Pulsed field ablation: focused on atrial fibrillation ablation.
Article Snippet: The integration of a variable loop circular catheter (VLCC, VaripulseTM, Biosense Webster) with a 3D mapping system has demonstrated the safety and efficacy of PFA for PVI in patients with PAF [75,76].

Article Title: Evaluating the Safety Profile and Learning Curve With a Pulsed Field Ablation Variable Loop Circular Catheter in Procedures for AF: Observations From the VARIPURE Prospective, Multicenter, Postmarket Study
Article Snippet: The long-term safety, effectiveness, and improved clinical outcomes of a biphasic PFA system with a variable-loop circular catheter (VLCC; VARIPULSE, Biosense Webster, Inc, part of Johnson & Johnson MedTech, Irvine, CA) in the treatment of patients with drug-refractory paroxysmal AF have been demonstrated in the prospective, multicenter, single-arm INSPIRE and ADMIRE clinical studies.1,2 In clinical practice, the adoption of new PFA devices is driven by perceived safety over thermal ablation and smooth learning curves.3 Thus far, real-world data on the safety and operator experience with the novel PFA VLCC are limited.

Derivative Assay:

Article Title: Contact Index–Guided Pulsed Field Ablation: A Two‐Phase Validation of the Impedance Change Threshold to Prevent Acute Pulmonary Vein Gaps
Article Snippet: .. The Tissue Proximity Indication, derived from impedance changes, enables a semi‐quantitative assessment of catheter–tissue contact when using a variable‐loop circular catheter (VLCC, VARIPULSE, Biosense Webster Inc., Irvine, CA) [ , , , ]. .. Recently, the EnSite X mapping system (Abbott, Abbott Park, IL) introduced a new module, the “Contact Index,” which allows real‐time visualization of impedance changes for each electrode on the pentaspline catheter (FARAPULSE, Boston Scientific, Marlborough, MA).



Similar Products

86
Boston Scientific Corporation variable loop pfa catheter
Variable Loop Pfa Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/catheter+pentaspline+pfa/pm42166081-34-6-10
Average 86 stars, based on 1 article reviews
variable loop pfa catheter - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Biosense Webster variable loop pfa catheter
Variable Loop Pfa Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/catheter+circular+loop+variable/pmc12618193-81-24-29
Average 86 stars, based on 1 article reviews
variable loop pfa catheter - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Biosense Webster shot variable loop pfa catheter
Shot Variable Loop Pfa Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/catheter+circular+loop+variable/pmc12626120-34-20-27
Average 86 stars, based on 1 article reviews
shot variable loop pfa catheter - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Biosense Webster varipulse variable loop pfa catheter
Varipulse Variable Loop Pfa Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/catheter+circular+loop+variable/pmc12593765-21-25-30
Average 86 stars, based on 1 article reviews
varipulse variable loop pfa catheter - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Biosense Webster biphasic pfa system with a variable-loop circular catheter varipulse
Biphasic Pfa System With A Variable Loop Circular Catheter Varipulse, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/biphasic+pfa+system+with+a+variable+loop+circular+catheter+varipulse/pm40281689-245-15-19
Average 90 stars, based on 1 article reviews
biphasic pfa system with a variable-loop circular catheter varipulse - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster variable loop pfa catheter varipulse catheter
Procedural characteristics
Variable Loop Pfa Catheter Varipulse Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/varipulse+catheter/pmc11879039-54-20-26
Average 90 stars, based on 1 article reviews
variable loop pfa catheter varipulse catheter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster varipulse variable-loop pfa catheter
Procedural characteristics
Varipulse Variable Loop Pfa Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/varipulse+catheter/pm39852288-141-17-21
Average 90 stars, based on 1 article reviews
varipulse variable-loop pfa catheter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster variable loop circular pfa catheter
Three-dimensional bipolar map of the LA and the right- and left-sided PVs in a posterior–anterior and a left lateral projection. The green dots mark <t>PFA-based</t> lesions around the ipsilateral PVs as applied by the lattice-tip mapping <t>and</t> <t>ablation</t> catheter.
Variable Loop Circular Pfa Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+pfa+catheter/pfa+circular+catheter/pmc11583048-48-96-100
Average 90 stars, based on 1 article reviews
variable loop circular pfa catheter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Procedural characteristics

Journal: Europace

Article Title: Early versus late atrial fibrillation recurrence after pulsed field ablation: insights from the admIRE trial

doi: 10.1093/europace/euaf007

Figure Lengend Snippet: Procedural characteristics

Article Snippet: The admIRE trial (NCT05293639) was a multicenter, prospective, nonrandomized, single-arm interventional study to assess the safety and effectiveness of a variable loop PFA catheter (Varipulse Catheter, Biosense Webster Inc., part of Johnson & Johnson MedTech, Irvine, CA, USA) with an integrated electroanatomical mapping system (CARTO Software, Biosense Webster Inc., part of Johnson & Johnson MedTech, Irvine, CA, USA).

Techniques:

Three-dimensional bipolar map of the LA and the right- and left-sided PVs in a posterior–anterior and a left lateral projection. The green dots mark PFA-based lesions around the ipsilateral PVs as applied by the lattice-tip mapping and ablation catheter.

Journal: Europace

Article Title: General anaesthesia and deep sedation for monopolar pulsed field ablation using a lattice-tip catheter combined with a novel three-dimensional mapping system

doi: 10.1093/europace/euae270

Figure Lengend Snippet: Three-dimensional bipolar map of the LA and the right- and left-sided PVs in a posterior–anterior and a left lateral projection. The green dots mark PFA-based lesions around the ipsilateral PVs as applied by the lattice-tip mapping and ablation catheter.

Article Snippet: This catheter can apply PFA as well as radiofrequency (RF) according to anatomical locations and operator’s choice and yields high flexibility for individual ablation strategies., , So far, Affera-based ablation was only performed in general anaesthesia (GA), and there is no experience for procedures in deep sedation., , However, in Europe and the USA, conscious or deep sedation is mainly used for electrophysiology procedures., Catheter ablation in deep sedation using fentanyl, midazolam, and a ketamine adjunct or midazolam, dexmedetomidine, and remifentanil was recently described for ablation with the Farapulse PFA catheter (Boston Scientific) or a variable loop circular PFA catheter (Biosense Webster)., The present study compared the safety and efficacy of Affera procedures with PFA and/or RF applications in atrial fibrillation (AF) patients ablated in deep sedation or in GA.

Techniques:

 Ablation  characteristics of PVI

Journal: Europace

Article Title: General anaesthesia and deep sedation for monopolar pulsed field ablation using a lattice-tip catheter combined with a novel three-dimensional mapping system

doi: 10.1093/europace/euae270

Figure Lengend Snippet: Ablation characteristics of PVI

Article Snippet: This catheter can apply PFA as well as radiofrequency (RF) according to anatomical locations and operator’s choice and yields high flexibility for individual ablation strategies., , So far, Affera-based ablation was only performed in general anaesthesia (GA), and there is no experience for procedures in deep sedation., , However, in Europe and the USA, conscious or deep sedation is mainly used for electrophysiology procedures., Catheter ablation in deep sedation using fentanyl, midazolam, and a ketamine adjunct or midazolam, dexmedetomidine, and remifentanil was recently described for ablation with the Farapulse PFA catheter (Boston Scientific) or a variable loop circular PFA catheter (Biosense Webster)., The present study compared the safety and efficacy of Affera procedures with PFA and/or RF applications in atrial fibrillation (AF) patients ablated in deep sedation or in GA.

Techniques: Isolation