Review



s3 non-contact microarray spotter  (SCIENION)


Bioz Verified Symbol SCIENION is a verified supplier
Bioz Manufacturer Symbol SCIENION manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    SCIENION s3 non-contact microarray spotter
    S3 Non Contact Microarray Spotter, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/sciflexarrayer+sx+microarray+printer/pmc08043673-656-24-28
    Average 90 stars, based on 1 article reviews
    s3 non-contact microarray spotter - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Multiplexed, quantitative serological profiling of COVID-19 from a drop of blood by a point-of-care test
    Article Snippet: Capture spots of the following proteins were printed as ~170 μm diameter spots using a Scienion S11 sciFLEXARRAYER (Scienion AG) inkjet printer: Spike S1 (Sino Biological, cat# 40591-V05H1), Spike RBD (Sino Biological, cat# 40592-V02H), and Nucleocapsid protein (Leinco, cat# S854).

    Article Title: A novel high performing multiplex immunoassay Multi-HTLV for serological confirmation and typing of HTLV infections
    Article Snippet: We used the SciFLEXARRAYER printing system (SCIENION, Germany) to print HTLV antigens, at the bottom of each well at precise X-Y coordinates, under controlled humidity and temperature parameters.

    Article Title: Gut microbiota-specific IgA + B cells traffic to the CNS in active multiple sclerosis
    Article Snippet: Solutions were transferred to a 384 well V bottom plate (Genetix) and robotically printed onto NHS activated glass slides (CodeLink slides, Surmodics) using an S3 non-contact microarray spotter (Scienion) equipped with a Type 4 coated nozzle (PDC80).

    Article Title: Chips, detection systems, and methods for multiplex pneumococcus serology
    Article Snippet: For the arrayer, a Scienion S3 microarrayer that works through piezoelectric dispensing was used.

    Microarray:

    Article Title: Poor antibody response to BioNTech/Pfizer COVID-19 vaccination in SARS-CoV-2 naïve residents of nursing homes
    Article Snippet: .. In this microarray, SARS-CoV-2 antigens, selected for their individual performance, were printed in 96-well polystyrene microplates using a sciFLEXARRAYER printing system (Scienion, Germany). ..

    Article Title: Highly multiplexed rapid DNA detection with single-nucleotide specificity via convective PCR in a portable device.
    Article Snippet: .. Microarrays were printed using Scienion S3 microarray printer equipped with PDC070 micronozzles. ..

    Article Title: Vaccines against
    Article Snippet: .. 64 well glycan arrays were printed using a Scienion S3 microarray printer on CodeLink® NHS activated glass slides (Surmodics). ..

    Article Title: Synthesis of oligosaccharides to identify an immunologically active epitope against Candida auris infection
    Article Snippet: .. The glycans were dissolved at 0.1 mM in 50 mM sodium phosphate buffer pH 8.5 and printed in 64 identical fields to NHS activated hydrogel glass slides (CodeLink slides, Surmodics) using a noncontact S3 microarray spotter (Scienion, Berlin, Germany). ..

    Glycoproteomics:

    Article Title: Vaccines against
    Article Snippet: .. 64 well glycan arrays were printed using a Scienion S3 microarray printer on CodeLink® NHS activated glass slides (Surmodics). ..



    Similar Products

    95
    SCIENION non contact sciflexarrayer s12 microarray spotter
    Non Contact Sciflexarrayer S12 Microarray Spotter, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/sciFLEXARRAYER+S12/pmc12532290__ja5c12690_si_001-588-37-42
    Average 95 stars, based on 1 article reviews
    non contact sciflexarrayer s12 microarray spotter - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    90
    SCIENION non-contact piezoelectric microarray spotter customized for r2r operation s12 sciflexarrayer
    Non Contact Piezoelectric Microarray Spotter Customized For R2r Operation S12 Sciflexarrayer, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/piezoelectric+spotter+sciflexarrayer+s3/pm40277543-89-20-24
    Average 90 stars, based on 1 article reviews
    non-contact piezoelectric microarray spotter customized for r2r operation s12 sciflexarrayer - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Arrayjet Limited non-contact marathon arrayjet microarray spotter
    Production of orthoflavivirus recombinant NS1 for sensitive and specific <t>microarray</t> detection of orthoflavivirus IgG. ( a ) Recombinant NS1 and ( b ) recombinant EDIII of TBEV, West Nile virus (WNV) lineage 2, dengue virus (DENV) DENV 1 , DENV 2 , DENV 3 , DENV 4 , Zika virus (ZIKV), Japanese encephalitis virus (JEV) and Usutu virus (USUV) were purified and then analyzed via SDS-PAGE.
    Non Contact Marathon Arrayjet Microarray Spotter, supplied by Arrayjet Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/inkjet+printer+aj100/pmc10892675-91-67-69
    Average 90 stars, based on 1 article reviews
    non-contact marathon arrayjet microarray spotter - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    SCIENION non-contact piezo dispensing microarray spotter
    Production of orthoflavivirus recombinant NS1 for sensitive and specific <t>microarray</t> detection of orthoflavivirus IgG. ( a ) Recombinant NS1 and ( b ) recombinant EDIII of TBEV, West Nile virus (WNV) lineage 2, dengue virus (DENV) DENV 1 , DENV 2 , DENV 3 , DENV 4 , Zika virus (ZIKV), Japanese encephalitis virus (JEV) and Usutu virus (USUV) were purified and then analyzed via SDS-PAGE.
    Non Contact Piezo Dispensing Microarray Spotter, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/non+contact+piezo+dispensing+microarray+spotter/pm36356507-49-32-37
    Average 90 stars, based on 1 article reviews
    non-contact piezo dispensing microarray spotter - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    SCIENION s3 non-contact microarray spotter
    Production of orthoflavivirus recombinant NS1 for sensitive and specific <t>microarray</t> detection of orthoflavivirus IgG. ( a ) Recombinant NS1 and ( b ) recombinant EDIII of TBEV, West Nile virus (WNV) lineage 2, dengue virus (DENV) DENV 1 , DENV 2 , DENV 3 , DENV 4 , Zika virus (ZIKV), Japanese encephalitis virus (JEV) and Usutu virus (USUV) were purified and then analyzed via SDS-PAGE.
    S3 Non Contact Microarray Spotter, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/sciflexarrayer+sx+microarray+printer/pmc08043673-656-24-28
    Average 90 stars, based on 1 article reviews
    s3 non-contact microarray spotter - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    SCIENION non-contact piezoelectric sciflexarrayer s1 microarray spotter
    Production of orthoflavivirus recombinant NS1 for sensitive and specific <t>microarray</t> detection of orthoflavivirus IgG. ( a ) Recombinant NS1 and ( b ) recombinant EDIII of TBEV, West Nile virus (WNV) lineage 2, dengue virus (DENV) DENV 1 , DENV 2 , DENV 3 , DENV 4 , Zika virus (ZIKV), Japanese encephalitis virus (JEV) and Usutu virus (USUV) were purified and then analyzed via SDS-PAGE.
    Non Contact Piezoelectric Sciflexarrayer S1 Microarray Spotter, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/piezoelectric+spotter+sciflexarrayer+s3/pm32298669-92-34-46
    Average 90 stars, based on 1 article reviews
    non-contact piezoelectric sciflexarrayer s1 microarray spotter - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Digilab Inc non-contact microarray spotter
    High-throughput AST chip. (A) A schematic of high-throughput antimicrobial susceptibility testing using AST-Chip. Antimicrobial susceptibility testing using the chip can be conducted in 12 h; <t>Microarray</t> micrograph of S. aureus cultures formed on hydrogel spots of AST-Chip after 12–18 h. The spots are interspaced at 1 mm with a spot diameter of 0.5 mm; The nano-biofilms analyzed using FUN-1 is demonstrated in green color; (B) BacLight live/dead assay shows metabolically active cells in yellow-orange color, present as colonies. The scale bar is 100 μm; (C) SEM micrograph of S. aureus nano-biofilm colonies. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
    Non Contact Microarray Spotter, supplied by Digilab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/microarray+spotter/pmc05686425-26-33-38
    Average 90 stars, based on 1 article reviews
    non-contact microarray spotter - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Digilab Inc non contact microarray spotter microsys 5100-4sq
    High-throughput AST chip. (A) A schematic of high-throughput antimicrobial susceptibility testing using AST-Chip. Antimicrobial susceptibility testing using the chip can be conducted in 12 h; <t>Microarray</t> micrograph of S. aureus cultures formed on hydrogel spots of AST-Chip after 12–18 h. The spots are interspaced at 1 mm with a spot diameter of 0.5 mm; The nano-biofilms analyzed using FUN-1 is demonstrated in green color; (B) BacLight live/dead assay shows metabolically active cells in yellow-orange color, present as colonies. The scale bar is 100 μm; (C) SEM micrograph of S. aureus nano-biofilm colonies. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
    Non Contact Microarray Spotter Microsys 5100 4sq, supplied by Digilab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/microsys++5100+4sq+microarray+spotter/pmc03900324-98-20-29
    Average 90 stars, based on 1 article reviews
    non contact microarray spotter microsys 5100-4sq - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    SCIENION piezoelectric dispensing non-contact microarray spotter scienion sciflexarrayer s11
    High-throughput AST chip. (A) A schematic of high-throughput antimicrobial susceptibility testing using AST-Chip. Antimicrobial susceptibility testing using the chip can be conducted in 12 h; <t>Microarray</t> micrograph of S. aureus cultures formed on hydrogel spots of AST-Chip after 12–18 h. The spots are interspaced at 1 mm with a spot diameter of 0.5 mm; The nano-biofilms analyzed using FUN-1 is demonstrated in green color; (B) BacLight live/dead assay shows metabolically active cells in yellow-orange color, present as colonies. The scale bar is 100 μm; (C) SEM micrograph of S. aureus nano-biofilm colonies. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
    Piezoelectric Dispensing Non Contact Microarray Spotter Scienion Sciflexarrayer S11, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+spotter/noncontact+microarray+spotter+sciflexarrayer+s12/pm23612063-117-4-7
    Average 90 stars, based on 1 article reviews
    piezoelectric dispensing non-contact microarray spotter scienion sciflexarrayer s11 - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    Production of orthoflavivirus recombinant NS1 for sensitive and specific microarray detection of orthoflavivirus IgG. ( a ) Recombinant NS1 and ( b ) recombinant EDIII of TBEV, West Nile virus (WNV) lineage 2, dengue virus (DENV) DENV 1 , DENV 2 , DENV 3 , DENV 4 , Zika virus (ZIKV), Japanese encephalitis virus (JEV) and Usutu virus (USUV) were purified and then analyzed via SDS-PAGE.

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: Production of orthoflavivirus recombinant NS1 for sensitive and specific microarray detection of orthoflavivirus IgG. ( a ) Recombinant NS1 and ( b ) recombinant EDIII of TBEV, West Nile virus (WNV) lineage 2, dengue virus (DENV) DENV 1 , DENV 2 , DENV 3 , DENV 4 , Zika virus (ZIKV), Japanese encephalitis virus (JEV) and Usutu virus (USUV) were purified and then analyzed via SDS-PAGE.

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Recombinant, Microarray, Virus, Purification, SDS Page

    Overview of serum collection used for orthoflavivirus  microarray  validation.

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: Overview of serum collection used for orthoflavivirus microarray validation.

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Microarray, Biomarker Discovery, Enzyme-linked Immunosorbent Assay, Virus, Neutralization

    Validation of orthoflavivirus recombinant NS1 for sensitive and specific microarray detection of orthoflavivirus IgG. Heatmaps displaying microarray titers for the orthoflavivirus rNS1 of ( a ) orthoflavivirus negative reference sera, ( b ) WNV patients, ( d ) ZIKV patients, ( f ) DENV patients and ( h ) TBEV patients. (The color key of the titers is indicated at the bottom of each heatmap). The microarray antigens are listed on the left of each heatmap. Violin plots showing microarray titers of ( c ) WNV patients, ( e ) ZIKV patients, ( g ) DENV patients and ( i ) TBEV natural infection-positive sera against the recombinant NS1 of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. A non-parametric t -test was performed to assess the statistical differences of paired samples. Significance is noted as ***, p < 0.001; *, p < 0.5. ( b ) Receiving operating characterization (ROC) curve was created with GraphPad Prism software (version 9.1.0).

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: Validation of orthoflavivirus recombinant NS1 for sensitive and specific microarray detection of orthoflavivirus IgG. Heatmaps displaying microarray titers for the orthoflavivirus rNS1 of ( a ) orthoflavivirus negative reference sera, ( b ) WNV patients, ( d ) ZIKV patients, ( f ) DENV patients and ( h ) TBEV patients. (The color key of the titers is indicated at the bottom of each heatmap). The microarray antigens are listed on the left of each heatmap. Violin plots showing microarray titers of ( c ) WNV patients, ( e ) ZIKV patients, ( g ) DENV patients and ( i ) TBEV natural infection-positive sera against the recombinant NS1 of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. A non-parametric t -test was performed to assess the statistical differences of paired samples. Significance is noted as ***, p < 0.001; *, p < 0.5. ( b ) Receiving operating characterization (ROC) curve was created with GraphPad Prism software (version 9.1.0).

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Biomarker Discovery, Recombinant, Microarray, Infection, Software

    ( a ) Heatmap displaying microarray titers for the orthoflavivirus rNS1 of orthoflavivirus TBEV-vaccinated patients. (The color key of the titers is indicated at the bottom of the heatmap). The microarray antigens are listed on the left of the heatmap. ( b ) Violin plot showing microarray titers of the pre-characterized TBEV, dengue virus (DENV), Zika virus (ZIKV), West Nile virus (WNV) sera and the negative orthoflavivirus sera against TBEV rEDIII. TBEV vaccinees were used as the positive control. ( c ) Heatmap displaying microarray titers for the orthoflavivirus rEDIII of orthoflavivirus TBEV-vaccinated patients. (The color key of the titers indicated at the bottom of the heatmap.) The microarray antigens are listed on the y-axis. ( d )Violin plot showing microarray titers of TBEV-vaccinated serum samples against the recombinant EDIII of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. A non-parametric T-test was performed to assess the statistical differences of paired samples. Significance is noted as ****, p < 0.0001; **, p < 0.01; *, p < 0.5. The order of patient samples is the same for each heatmap.

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: ( a ) Heatmap displaying microarray titers for the orthoflavivirus rNS1 of orthoflavivirus TBEV-vaccinated patients. (The color key of the titers is indicated at the bottom of the heatmap). The microarray antigens are listed on the left of the heatmap. ( b ) Violin plot showing microarray titers of the pre-characterized TBEV, dengue virus (DENV), Zika virus (ZIKV), West Nile virus (WNV) sera and the negative orthoflavivirus sera against TBEV rEDIII. TBEV vaccinees were used as the positive control. ( c ) Heatmap displaying microarray titers for the orthoflavivirus rEDIII of orthoflavivirus TBEV-vaccinated patients. (The color key of the titers indicated at the bottom of the heatmap.) The microarray antigens are listed on the y-axis. ( d )Violin plot showing microarray titers of TBEV-vaccinated serum samples against the recombinant EDIII of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. A non-parametric T-test was performed to assess the statistical differences of paired samples. Significance is noted as ****, p < 0.0001; **, p < 0.01; *, p < 0.5. The order of patient samples is the same for each heatmap.

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Microarray, Virus, Positive Control, Recombinant

    TBEV-infected serum samples against recombinant EDIII. ( a ) Heatmap displaying microarray titers for the orthoflavivirus rEDIII of orthoflavivirus TBEV natural infection-positive sera. (The color key of the titers is indicated at the bottom of each heatmap). The microarray antigens are listed on the y-axis. ( b ) Violin plots showing the microarray titers of TBEV natural infection-positive sera against the recombinant EDIII of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. A non-parametric T-test was performed to assess the statistical differences of paired samples. Significance is noted as ****, p < 0.0001; ***, p < 0.001; *, p < 0.5. ( c ) Receiving operating characterization (ROC) curve was created with GraphPad Prism software (version 9.1.0). The order of patient samples is the same as in .

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: TBEV-infected serum samples against recombinant EDIII. ( a ) Heatmap displaying microarray titers for the orthoflavivirus rEDIII of orthoflavivirus TBEV natural infection-positive sera. (The color key of the titers is indicated at the bottom of each heatmap). The microarray antigens are listed on the y-axis. ( b ) Violin plots showing the microarray titers of TBEV natural infection-positive sera against the recombinant EDIII of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. A non-parametric T-test was performed to assess the statistical differences of paired samples. Significance is noted as ****, p < 0.0001; ***, p < 0.001; *, p < 0.5. ( c ) Receiving operating characterization (ROC) curve was created with GraphPad Prism software (version 9.1.0). The order of patient samples is the same as in .

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Infection, Recombinant, Microarray, Software

    Evaluation of recombinant orthoflavivirus EDIII as an antigen. Heatmaps and violin plots showing the microarray titers of ZIKV-positive sera ( a , b ), DENV-positive sera ( c , d ) and WNV-positive sera ( e , f ) against the recombinant rEDIII of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. The order of patient samples is the same as in .

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: Evaluation of recombinant orthoflavivirus EDIII as an antigen. Heatmaps and violin plots showing the microarray titers of ZIKV-positive sera ( a , b ), DENV-positive sera ( c , d ) and WNV-positive sera ( e , f ) against the recombinant rEDIII of TBEV, DENV1, DENV2, DENV3, DENV4, ZIKV, WNV, USUV and JEV. The order of patient samples is the same as in .

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Recombinant, Microarray

    All TBEV serology results of sera ( n = 5) that tested TBEV IgG positive for rNS1 and/or rEDIII in the orthoflavivirus  microarray.

    Journal: Viruses

    Article Title: Multiplex Serology for Sensitive and Specific Flavivirus IgG Detection: Addition of Envelope Protein Domain III to NS1 Increases Sensitivity for Tick-Borne Encephalitis Virus IgG Detection

    doi: 10.3390/v16020286

    Figure Lengend Snippet: All TBEV serology results of sera ( n = 5) that tested TBEV IgG positive for rNS1 and/or rEDIII in the orthoflavivirus microarray.

    Article Snippet: TBEV rEDIII and the rNS1 of DENV 1 , DENV 2 , DENV 3 , DENV 4 , JEV, TBEV, USUV, WNV lineage 2 and ZIKV at concentrations of 1.5 mg/mL were mixed with 2× protein printing buffer (GVS, Sandford, FL, USA) and spotted in duplicate in three drops of 333 pL each on 24-pad nitrocellulose-coated slides (ONCYTE AVID, GraceBio Labs, Bend, OR, USA) by using a non-contact Marathon Arrayjet microarray spotter (Roslin, UK).

    Techniques: Microarray, Enzyme-linked Immunosorbent Assay, Infection

    High-throughput AST chip. (A) A schematic of high-throughput antimicrobial susceptibility testing using AST-Chip. Antimicrobial susceptibility testing using the chip can be conducted in 12 h; Microarray micrograph of S. aureus cultures formed on hydrogel spots of AST-Chip after 12–18 h. The spots are interspaced at 1 mm with a spot diameter of 0.5 mm; The nano-biofilms analyzed using FUN-1 is demonstrated in green color; (B) BacLight live/dead assay shows metabolically active cells in yellow-orange color, present as colonies. The scale bar is 100 μm; (C) SEM micrograph of S. aureus nano-biofilm colonies. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

    Journal: Biotechnology Reports

    Article Title: High-throughput microarray for antimicrobial susceptibility testing

    doi: 10.1016/j.btre.2017.10.004

    Figure Lengend Snippet: High-throughput AST chip. (A) A schematic of high-throughput antimicrobial susceptibility testing using AST-Chip. Antimicrobial susceptibility testing using the chip can be conducted in 12 h; Microarray micrograph of S. aureus cultures formed on hydrogel spots of AST-Chip after 12–18 h. The spots are interspaced at 1 mm with a spot diameter of 0.5 mm; The nano-biofilms analyzed using FUN-1 is demonstrated in green color; (B) BacLight live/dead assay shows metabolically active cells in yellow-orange color, present as colonies. The scale bar is 100 μm; (C) SEM micrograph of S. aureus nano-biofilm colonies. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

    Article Snippet: Any subsequent dilutions needed for the antimicrobial susceptibility assays were made in PBS, mixed in a suspension of 0.5% alginate, and optimized media, and 50 nL of this mixture was spotted using a non-contact microarray spotter (Omnigrid Micro, Digilab Inc., Holliston, MA) on modified glass slides.

    Techniques: High Throughput Screening Assay, Microarray, Live Dead Assay, Metabolic Labelling

    Antimicrobial susceptibility profile of S. aureus . AST of methicillin against wild-type (UAMS-1WT) and community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA). (A) Microarray scanner image of AST-Chip with S. aureus cultures exposed to different concentrations of methicillin [MET]. The viability is indicated by the fluorescence intensity of the spots. (B) Scanning electron micrographs of S. aureus biofilms that are untreated (top) or treated with 10 μg/ml MET (bottom); (C) Dose-response profile of S. aureus cultures obtained using AST-Chip.

    Journal: Biotechnology Reports

    Article Title: High-throughput microarray for antimicrobial susceptibility testing

    doi: 10.1016/j.btre.2017.10.004

    Figure Lengend Snippet: Antimicrobial susceptibility profile of S. aureus . AST of methicillin against wild-type (UAMS-1WT) and community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA). (A) Microarray scanner image of AST-Chip with S. aureus cultures exposed to different concentrations of methicillin [MET]. The viability is indicated by the fluorescence intensity of the spots. (B) Scanning electron micrographs of S. aureus biofilms that are untreated (top) or treated with 10 μg/ml MET (bottom); (C) Dose-response profile of S. aureus cultures obtained using AST-Chip.

    Article Snippet: Any subsequent dilutions needed for the antimicrobial susceptibility assays were made in PBS, mixed in a suspension of 0.5% alginate, and optimized media, and 50 nL of this mixture was spotted using a non-contact microarray spotter (Omnigrid Micro, Digilab Inc., Holliston, MA) on modified glass slides.

    Techniques: Microarray, Fluorescence