Review



microsys 5100-4sq non-contact robotic microarray spotting system  (Digilab Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Digilab Inc microsys 5100-4sq non-contact robotic microarray spotting system
    Microsys 5100 4sq Non Contact Robotic Microarray Spotting System, supplied by Digilab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/microsys++5100+4sq+microarray+spotter/pmc05106528-168-2-4
    Average 90 stars, based on 1 article reviews
    microsys 5100-4sq non-contact robotic microarray spotting system - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: High-Throughput Discovery of Targeted, Minimally Complex Peptide Surfaces for Human Pluripotent Stem Cell Culture.
    Article Snippet: Human pluripotent stem cells harbor an unlimited capacity to generate therapeutically relevant cells for applications in regenerative medicine.. However, to utilize these cells in the clinic, scalable culture systems that activate defined receptors and signaling pathways to sustain stem cell self-renewal are required; and synthetic materials offer considerable promise to meet these needs.. De novo development of materials that target novel pathways has been stymied by a limited understanding of critical receptor interactions maintaining pluripotency.

    Article Title: Microarray platform affords improved product analysis in mammalian cell growth studies
    Article Snippet: Briefly, a poly-L-lysine (PLL)–BaCl 2 mixture was prepared by mixing a sterile 0.1 M BaCl 2 solution in deionized water with a 0.01% (w/v) sterile PLL solution (Sigma) in a 1:2 volume ratio.

    Article Title: Fibroblast Growth Factor-based Signaling through Synthetic Heparan Sulfate Blocks Copolymers Studied Using High Cell Density Three-dimensional Cell Printing
    Article Snippet: A freshly prepared solution of 0.1 m m BaCl 2 and poly- l -lysine solution (0.1% w/v) was mixed (1:2) and microarrayed (spotted) onto the slide in a 2 × 4-block pattern, with a 6 × 8 spot array in each block, using MicrosSys 5100–4SQ microcontact microarray spotter (Digilab, Inc., Marlborough, MA).

    Article Title: High-Throughput Toxicity and Phenotypic Screening of 3D Human Neural Progenitor Cell Cultures on a Microarray Chip Platform
    Article Snippet: An enclosed MicroSys 5100-4SQ (DigiLab) non-contact robotic microarray spotting system was used for printing.

    Article Title: Fibroblast Growth Factor-based Signaling through Synthetic Heparan Sulfate Blocks Copolymers Studied Using High Cell Density Three-dimensional Cell Printing
    Article Snippet: A freshly prepared solution of 0.1 mM BaCl2 and poly-L-lysine solution (0.1% w/v) was mixed (1:2) and microarrayed (spotted) onto the slide in a 2 4-block pattern, with a 6 8 spot array in each block, using MicrosSys 5100 – 4SQ microcontact microarray spotter (Digilab, Inc., Marlborough, MA).

    Article Title: Fibroblast Growth Factor-based Signaling through Synthetic Heparan Sulfate Blocks Copolymers Studied Using High Cell Density Three-dimensional Cell Printing
    Article Snippet: The poly(styrene co-malic anhydride) solution was then spin-coated onto acid-washed microscope slides using a Laurell Technologies (North Wales, PA) WS-400B spin-coater.

    Article Title: Metabolic Enzyme Microarray Coupled with Miniaturized Cell-Culture Array Technology for High-Throughput Toxicity Screening
    Article Snippet: Immediately before spotting the sol solution onto the slides, mix 3 mL of the MTMOS–HCl sol solution with 1 mL of Dulbecco’s PBS without CaCl 2 and MgCl 2 and use this mixture within 1 h. After aligning the MTMOS-coated slides on the slide deck of a MicroSysTM 5100-4SQ microarray spotter (Genomics Solutions, now Digilab, Inc.), print the mixture onto the periphery of each slide (typically 80 spots/slide, 450 nL per spot, 2 mm spot-to-spot distance).

    Microarray:

    Article Title: FGF-FGFR Signaling Mediated through Glycosaminoglycans in Microtiter Plate and Cell-Based Microarray Platforms
    Article Snippet: .. A 30 nL solution of a 0.1 mM BaCl 2 :poly-L-lysine (1:2) was spotted onto PSMA coated slides using a MicroSys 5100-4SQ non contact microarray spotter (Genomic Solutions, now Digilab, Inc., Marlborough, MA) and left to dry for approximately 1 h. Briefly, this microarray-based approach employs pump-based aspiration and dispensing through a 100 micron ceramic tip with high positional accuracy. ..



    Similar Products

    90
    Arrayjet Limited non-contact microarray robot
    Non Contact Microarray Robot, supplied by Arrayjet Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/microarray+robot+sprint/pm40623969-391-30-33
    Average 90 stars, based on 1 article reviews
    non-contact microarray robot - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    96
    SCIENION non contact microarray printing robot
    Figure 2. (A) Layout of the biomarker <t>microarray</t> (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.
    Non Contact Microarray Printing Robot, supplied by SCIENION, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/sciFLEXARRAYER+S3/pm40047601-58-6-12
    Average 96 stars, based on 1 article reviews
    non contact microarray printing robot - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    90
    SCIENION non-contact microarray printing robot sciflexarrayer s1
    Figure 2. (A) Layout of the biomarker <t>microarray</t> (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.
    Non Contact Microarray Printing Robot Sciflexarrayer S1, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/noncontact+microarray+printer/pm30900531-80-5-11
    Average 90 stars, based on 1 article reviews
    non-contact microarray printing robot sciflexarrayer s1 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Digilab Inc microsys 5100-4sq non-contact robotic microarray spotting system
    Figure 2. (A) Layout of the biomarker <t>microarray</t> (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.
    Microsys 5100 4sq Non Contact Robotic Microarray Spotting System, supplied by Digilab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/microsys++5100+4sq+microarray+spotter/pmc05106528-168-2-4
    Average 90 stars, based on 1 article reviews
    microsys 5100-4sq non-contact robotic microarray spotting system - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Arrayjet Limited piezoelectric non-contact microarray robot sprint
    Figure 2. (A) Layout of the biomarker <t>microarray</t> (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.
    Piezoelectric Non Contact Microarray Robot Sprint, supplied by Arrayjet Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/microarray+robot+sprint/pm26384432-377-7-12
    Average 90 stars, based on 1 article reviews
    piezoelectric non-contact microarray robot sprint - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Gesellschaft fur Silizium-Mikrosysteme non-contact microarray robot
    Figure 2. (A) Layout of the biomarker <t>microarray</t> (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.
    Non Contact Microarray Robot, supplied by Gesellschaft fur Silizium-Mikrosysteme, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/non-contact+microarray+robot/nano+plotter+2+1/10__3390_slash_molecules21060750-245-11-14
    Average 90 stars, based on 1 article reviews
    non-contact microarray robot - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Figure 2. (A) Layout of the biomarker microarray (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.

    Journal: Micromachines

    Article Title: Portable Fluorescence Microarray Reader-Enabled Biomarker Panel Detection System for Point-of-Care Diagnosis of Lupus Nephritis.

    doi: 10.3390/mi16020156

    Figure Lengend Snippet: Figure 2. (A) Layout of the biomarker microarray (BMA) slide, showing the arrangement of capture antibodies and controls within each well. (B) Illustration of the BMA slide design with 16 wells and its alignment within the slide holder for analysis. The numbers along the side correspond to the row numbers of each well, while the numbers along the bottom represent the column positions of the slide.

    Article Snippet: The slides were prepared using a non-contact microarray printing robot (sciFLEXARRAYER S3; Scienion GmbH, Berlin, Germany), which printed capture antibodies for each biomarker in triplicate at a controlled drop volume of 450 ± 20 pL.

    Techniques: Biomarker Discovery, Microarray