Review



horiba macro ram raman spectrometer  (HORIBA Ltd)


Bioz Verified Symbol HORIBA Ltd is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    HORIBA Ltd horiba macro ram raman spectrometer
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Horiba Macro Ram Raman Spectrometer, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 95/100, based on 84 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/MacroRAM/pmc13389852-91-7-11
    Average 95 stars, based on 84 article reviews
    horiba macro ram raman spectrometer - by Bioz Stars, 2026-10
    95/100 stars

    Images

    1) Product Images from "Design, characterization, and application of a mixed metal oxide (Al 2 O 3 –La 2 O 3 –V 2 O 5 ) nanocomposite in photocatalytic degradation of methylene blue: a multi-technique approach"

    Article Title: Design, characterization, and application of a mixed metal oxide (Al 2 O 3 –La 2 O 3 –V 2 O 5 ) nanocomposite in photocatalytic degradation of methylene blue: a multi-technique approach

    Journal: RSC Advances

    doi: 10.1039/d6ra04119a

    Raman spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Figure Legend Snippet: Raman spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.

    Techniques Used: Raman Spectroscopy

    Related Articles

    Analysis:

    Article Title: Amorphous Calcium Phosphate Maintains Casein Microarchitecture while Modulating Bacterial Growth Kinetics.
    Article Snippet: .. Raman spectroscopic analysis was performed on suspensions placed inside quartz cuvettes on a Horiba MacroRam spectrometer using the 785 nm excitation from a diode pumped solid-state laser and the output power of 5 mW. .. UV/Vis spectroscopic analysis was carried out on an Agilent Carey 60 spectrophotometer while the analysis of fluorescence emission spectra was performed on a Horiba Quantamaster 8075 fluorometer.

    Quartz:

    Article Title: Amorphous Calcium Phosphate Maintains Casein Microarchitecture while Modulating Bacterial Growth Kinetics.
    Article Snippet: .. Raman spectroscopic analysis was performed on suspensions placed inside quartz cuvettes on a Horiba MacroRam spectrometer using the 785 nm excitation from a diode pumped solid-state laser and the output power of 5 mW. .. UV/Vis spectroscopic analysis was carried out on an Agilent Carey 60 spectrophotometer while the analysis of fluorescence emission spectra was performed on a Horiba Quantamaster 8075 fluorometer.

    other:

    Article Title: Hydrophobic sulfur vacancy rich MoS 2 encapsulation of lead-free halide perovskites for aqueous catalysis
    Article Snippet: Vibrational properties were characterized using Fourier transform infrared spectroscopy (FTIR) (IRSpirit, Shimadzu) and Raman spectroscopy (macroRam, Horiba).

    Article Title: Chemical Composition, Physicochemical Properties, and Morphological Characterization of Granules of AmmoniumNitrate Modified by Serpentinite Additive
    Article Snippet: Spectra were recorded using a Macro RAM benchtop Raman spectrometer (HORIBA Scientific) with a 785 nm excitation laser, over 100–3400 cm –1 at a spectral resolution of 8 cm –1 .

    Raman Spectroscopy:


    Synthesized:

    Article Title: Green synthesis of wurtzite ZnO nanoparticles via Indigofera tinctoria stem extract: linking crystallinity with photocatalytic and biological performance
    Article Snippet: .. The Raman spectrum of the synthesized ZnO nanoparticle was recorded using a Raman spectrometer (Horiba MacroRam) with a 785 nm diode laser as the excitation source (laser power of 5 mW) at room temperature. .. The electrochemical impedance spectrum was obtained using an impedance analyzer (Agilent 4294A).



    Similar Products

    96
    Olympus mvx10 macroview stereo fluorescence microscope
    Mvx10 Macroview Stereo Fluorescence Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/MVX10+Macro+Zoom+Fluorescence+Microscope+System/pm42823455-434-6-5
    Average 96 stars, based on 1 article reviews
    mvx10 macroview stereo fluorescence microscope - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    95
    HORIBA Ltd macro ram benchtop raman spectrometer
    <t>Raman</t> spectrum of the selected AN-0.025SP granules prepared at an AN/SP mass ratio of 100:2.5.
    Macro Ram Benchtop Raman Spectrometer, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/MacroRAM/pmc13584579-156-5-10
    Average 95 stars, based on 1 article reviews
    macro ram benchtop raman spectrometer - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    95
    HORIBA Ltd horiba macro ram raman spectrometer
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Horiba Macro Ram Raman Spectrometer, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/MacroRAM/pmc13389852-91-7-11
    Average 95 stars, based on 1 article reviews
    horiba macro ram raman spectrometer - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    86
    Sable Systems International macrointerpreter version 26 1 macro version 1 5 7
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Macrointerpreter Version 26 1 Macro Version 1 5 7, supplied by Sable Systems International, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/1+1+26+5+7+macro+macrointerpreter+version+version/pmc13248870-39-12-9
    Average 86 stars, based on 1 article reviews
    macrointerpreter version 26 1 macro version 1 5 7 - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Navitar Inc adjustable macro lens
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Adjustable Macro Lens, supplied by Navitar Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/adjustable+lens+macro/pmc13253138-426-25-28
    Average 86 stars, based on 1 article reviews
    adjustable macro lens - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    96
    Olympus olympus mvx10 stereo microscope
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Olympus Mvx10 Stereo Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/MVX10+Macro+Zoom+Fluorescence+Microscope+System/pmc12856142-65-5-5
    Average 96 stars, based on 1 article reviews
    olympus mvx10 stereo microscope - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    95
    HORIBA Ltd horiba macro ramtm spectrometer
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Horiba Macro Ramtm Spectrometer, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/MacroRAM/pmc13202523-93-15-15
    Average 95 stars, based on 1 article reviews
    horiba macro ramtm spectrometer - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    99
    MedChemExpress macro autophagy
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Macro Autophagy, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/3-Methyladenine/pm42165871-63-3-13
    Average 99 stars, based on 1 article reviews
    macro autophagy - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    86
    Activinsights Ltd excel macro
    <t>Raman</t> spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.
    Excel Macro, supplied by Activinsights Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/excel+macro/pm42073131-81-6-10
    Average 86 stars, based on 1 article reviews
    excel macro - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Radimetrics Inc imagej macro
    (a) The study population, and (b) the workflow for automated slice-specific calculation of the volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimate using the <t>ImageJ</t> <t>macro.</t> CTDI vol , volume computed tomography dose index; D w , water-equivalent diameter; SSDE, size-specific dose estimate.
    Imagej Macro, supplied by Radimetrics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macro/imagej+macro/pmc13136667-98-23-26
    Average 86 stars, based on 1 article reviews
    imagej macro - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    Image Search Results


    Raman spectrum of the selected AN-0.025SP granules prepared at an AN/SP mass ratio of 100:2.5.

    Journal: ACS Omega

    Article Title: Chemical Composition, Physicochemical Properties, and Morphological Characterization of Granules of AmmoniumNitrate Modified by Serpentinite Additive

    doi: 10.1021/acsomega.6c06718

    Figure Lengend Snippet: Raman spectrum of the selected AN-0.025SP granules prepared at an AN/SP mass ratio of 100:2.5.

    Article Snippet: Spectra were recorded using a Macro RAM benchtop Raman spectrometer (HORIBA Scientific) with a 785 nm excitation laser, over 100–3400 cm –1 at a spectral resolution of 8 cm –1 .

    Techniques:

    Raman spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.

    Journal: RSC Advances

    Article Title: Design, characterization, and application of a mixed metal oxide (Al 2 O 3 –La 2 O 3 –V 2 O 5 ) nanocomposite in photocatalytic degradation of methylene blue: a multi-technique approach

    doi: 10.1039/d6ra04119a

    Figure Lengend Snippet: Raman spectroscopy of Al 2 O 3 –La 2 O 3 –V 2 O 5 nanocomposites.

    Article Snippet: Raman spectroscopy studies were performed with a HORIBA MACRO-RAM Raman Spectrometer (HORIBA Scientific, India).

    Techniques: Raman Spectroscopy

    (a) The study population, and (b) the workflow for automated slice-specific calculation of the volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimate using the ImageJ macro. CTDI vol , volume computed tomography dose index; D w , water-equivalent diameter; SSDE, size-specific dose estimate.

    Journal: Diagnostic and Interventional Radiology

    Article Title: Automated calculation of slice-specific volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimation for computed tomography scans

    doi: 10.4274/dir.2025.253555

    Figure Lengend Snippet: (a) The study population, and (b) the workflow for automated slice-specific calculation of the volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimate using the ImageJ macro. CTDI vol , volume computed tomography dose index; D w , water-equivalent diameter; SSDE, size-specific dose estimate.

    Article Snippet: For the SSDE, the mean difference was –0.123 mGy (–1.911 to 1.665 mGy), with an ICC of 0.967, confirming near-perfect agreement between the ImageJ macro and Radimetrics for head scans on Scanner B.

    Techniques: Computed Tomography

    Bland–Altman plots comparing the dose parameters obtained from the ImageJ macro and the scanner console display (Scanner A) for (a) volume computed tomography dose index (CTDI vol ), (b) water-equivalent diameter (D w ), and (c) size-specific dose estimate (SSDE) in head computed tomography (CT) examinations and (d) CTDI vol , (e) D w , and (f) SSDE in chest/abdomen CT examinations. LOA, limits of agreement; ICC, intraclass correlation coefficient.

    Journal: Diagnostic and Interventional Radiology

    Article Title: Automated calculation of slice-specific volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimation for computed tomography scans

    doi: 10.4274/dir.2025.253555

    Figure Lengend Snippet: Bland–Altman plots comparing the dose parameters obtained from the ImageJ macro and the scanner console display (Scanner A) for (a) volume computed tomography dose index (CTDI vol ), (b) water-equivalent diameter (D w ), and (c) size-specific dose estimate (SSDE) in head computed tomography (CT) examinations and (d) CTDI vol , (e) D w , and (f) SSDE in chest/abdomen CT examinations. LOA, limits of agreement; ICC, intraclass correlation coefficient.

    Article Snippet: For the SSDE, the mean difference was –0.123 mGy (–1.911 to 1.665 mGy), with an ICC of 0.967, confirming near-perfect agreement between the ImageJ macro and Radimetrics for head scans on Scanner B.

    Techniques: Computed Tomography

    Bland–Altman plots comparing the dose parameters obtained from the ImageJ macro and Radimetrics (Scanner B) for (a) volume computed tomography dose index (CTDI vol ), (b) water-equivalent diameter (D w ), and (c) size-specific dose estimate (SSDE) in head computed tomography (CT) examinations and (d) CTDI vol , (e) D w , and (f) SSDE in chest/abdomen CT examinations. LOA, limits of agreement; ICC, intraclass correlation coefficient.

    Journal: Diagnostic and Interventional Radiology

    Article Title: Automated calculation of slice-specific volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimation for computed tomography scans

    doi: 10.4274/dir.2025.253555

    Figure Lengend Snippet: Bland–Altman plots comparing the dose parameters obtained from the ImageJ macro and Radimetrics (Scanner B) for (a) volume computed tomography dose index (CTDI vol ), (b) water-equivalent diameter (D w ), and (c) size-specific dose estimate (SSDE) in head computed tomography (CT) examinations and (d) CTDI vol , (e) D w , and (f) SSDE in chest/abdomen CT examinations. LOA, limits of agreement; ICC, intraclass correlation coefficient.

    Article Snippet: For the SSDE, the mean difference was –0.123 mGy (–1.911 to 1.665 mGy), with an ICC of 0.967, confirming near-perfect agreement between the ImageJ macro and Radimetrics for head scans on Scanner B.

    Techniques: Computed Tomography

    Box plot comparison of (a) the water-equivalent diameter and (b) size-specific dose estimate obtained from the ImageJ macro, computed tomography scanner console, and Radimetrics across anatomical regions and scanners. Boxes represent the interquartile range, center lines indicate the median, whiskers extend to the data range, and crosses (×) represent the mean values. CT, computed tomography; D w , water-equivalent diameter; SSDE, size-specific dose estimate.

    Journal: Diagnostic and Interventional Radiology

    Article Title: Automated calculation of slice-specific volume computed tomography dose index, water-equivalent diameter, and size-specific dose estimation for computed tomography scans

    doi: 10.4274/dir.2025.253555

    Figure Lengend Snippet: Box plot comparison of (a) the water-equivalent diameter and (b) size-specific dose estimate obtained from the ImageJ macro, computed tomography scanner console, and Radimetrics across anatomical regions and scanners. Boxes represent the interquartile range, center lines indicate the median, whiskers extend to the data range, and crosses (×) represent the mean values. CT, computed tomography; D w , water-equivalent diameter; SSDE, size-specific dose estimate.

    Article Snippet: For the SSDE, the mean difference was –0.123 mGy (–1.911 to 1.665 mGy), with an ICC of 0.967, confirming near-perfect agreement between the ImageJ macro and Radimetrics for head scans on Scanner B.

    Techniques: Comparison, Computed Tomography