human complement sera (Innovative Research Inc)
Structured Review

Human Complement Sera, supplied by Innovative Research Inc, used in various techniques. Bioz Stars score: 93/100, based on 2 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+complement+plasma/Pooled+Human+Complement+Plasma/pmc12122657-67-1-14
Average 93 stars, based on 2 article reviews
Images
1) Product Images from "A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum"
Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum
Journal: Analytical and Bioanalytical Chemistry
doi: 10.1007/s00216-025-05882-4
Figure Legend Snippet: Optimization of the liposome composition to generate stealth liposomes. a Homogeneous complement assay of 10 mM SRB-encapsulating liposomes (10 µM total lipids; batches –6) showing the cholesterol dependency of liposome stealthiness in active serum (10 vol% PHS). Statistical analysis (two-sample independent t-test) revealed a significant difference between active and inactive serum samples at a cholesterol content of 10 mol% (p = 0.026) and above (p < 0.001). In contrast, no significant difference was observed at a cholesterol content of 5 mol% (p = 0.881). b Liposome stealthiness in active serum depending on SRB and cholesterol content (batches –10). 10 vol% human serum was used as a complement source (IRS41174). Statistical analysis (two-sample independent t-test) showed no significant difference between active and inactive serum samples of liposomes containing 10 mM SRB and 5 mol% cholesterol (p = 0.714), while in the other cases either a statistically significant amount of complement lysis (p < 0.001) or general serum stability was observed. Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS, and 30 mM OG + aS. Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5 or 8) nm and λ Em = 585(5 or 8) nm; gain 150. T = 37 °C. n = 3. c Heterogeneous complement assay of biotin-modified chemiluminescence liposomes (30 mM m -carboxy luminol; batches CL1–2). Statistical analysis (two-sample independent t-test) showed a significant difference between active and inactive serum samples of high-cholesterol liposomes. Low-cholesterol liposomes remained stealth and showed no statistical difference in 5 and 10 vol% serum, whereas 25 vol% led to minor lysis in active serum. Liposomes (50 μM total lipids) were immobilized overnight on a streptavidin-coated MTP and incubated for 1 h at 37 °C in either inactive serum or active serum (5, 10, or 25 vol% PHS in LCB). Chemiluminescence measurements were performed by adding 50 μL of 4 μM hemin and 50 μL 40 mM H 2 O 2 in 0.01 M CBS, pH 10.5, 2 s integration time, gain 80, RH 1 mm, T = 25 °C, n = 3. d Flow chart of the homogeneous complement assay procedure for SRB-encapsulating liposomes
Techniques Used: Liposomes, Complement Assay, Lysis, Fluorescence, Positive Control, Modification, Incubation
Figure Legend Snippet: Homogeneous complement assay of 10 mM SRB-liposomes using antibodies as complement trigger. Time-resolved normalized fluorescence intensities of 0.5 mol% ARMS-modified liposomes (10 µM total lipids; batch ) a without or d with 0.5 mol% complement-triggering anti-ARMS antibody (A626). ARMS-liposomes were incubated with the A626 antibody for 1 h at 300 rpm. 10 vol% human serum was used as complement source (IRS35577). Time-resolved fluorescence intensities of biotinylated liposomes (1 µM total lipids; batch ) b without or e with 0.5 mol% complement-triggering anti-biotin antibody. Biotin-liposomes were incubated with the anti-biotin antibody for 1 h at 300 rpm. 5 vol% human serum was used as complement source (IRS45270). Time-resolved fluorescence intensities of PEGylated liposomes (1 µM total lipids; batch ) c without or f with 0.05 mol% complement-triggering anti-PEG antibody (clone RM105). PEG-liposomes were incubated with the anti-PEG antibody for 1 h at 300 rpm in 5 µL HSS. 5 vol% human serum was used as complement source (IRS45270). Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS and 30 mM OG + aS and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3
Techniques Used: Complement Assay, Liposomes, Fluorescence, Modification, Incubation, Positive Control
Figure Legend Snippet: Dose–response curves of liposome lysis dependent on the antibody concentration. Corrected lysis values of a Biotin- (batch ) or b , c PEG-biotin-liposomes (batch ) (10 mM SRB, 1 µM total lipids) in a homogeneous complement assay performing an anti-biotin or anti-PEG (clone RM105 or clone 6.3) antibody titration. d Different combinations of these antibodies (0.03 mol% clone RM105, 0.1 mol% clone 6.3, 0.3 mol% anti-biotin antibody) with PEG biotin-liposomes (batch ). A one-way ANOVA, including a post hoc Tukey test, was performed for statistical analysis (p < 0.05) of the antibody combinations. Liposomes were incubated with the respective amount of antibodies for 1 h at 300 rpm. 5 vol% human serum was used as a complement source (IRS45270). Fluorescence intensities were adjusted by the iaS signal and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3
Techniques Used: Lysis, Concentration Assay, Liposomes, Complement Assay, Titration, Incubation, Fluorescence, Positive Control
Figure Legend Snippet: Screening of anti-PEG antibodies in human sera. Corrected lysis values of PEGylated 10 mM SRB-liposomes (1 µM total lipids; batch ) in a homogeneous complement assay performing a serum titration of different commercial sera (IRS batches 31,758, 35,577, 41,174, and 45,270). 0.1–10 vol% of human sera were used. Fluorescence intensities were adjusted by the iaS signal and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3
Techniques Used: Lysis, Liposomes, Complement Assay, Titration, Fluorescence, Positive Control
Figure Legend Snippet: Long-term storage stability study of 10 mM SRB-liposomes. Normalized fluorescence intensities of SRB-liposomes (10 µM total lipids) with different lipid compositions: a low-cholesterol, carboxylated (batch ); b low-cholesterol, PEGylated (batch ); and c high-cholesterol, biotinylated (batch ) in LCB, aS, or iaS throughout the long-term storage stability study up to 40 months at 4 °C. 10 vol% human serum was used as a complement source (PHS for 0–10 months and IRS45270 for the 40 months datapoint). Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5) nm and λ Em = 585(5) nm; gain 150. T = 37 °C. n = 3. d Summary of the liposome storage stability at 4 °C, RT, and 37 °C
Techniques Used: Liposomes, Fluorescence, Positive Control
Related Articles
Sequencing:Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum Article Snippet: The phospholipids 1,2-dipalmitoyl- sn -glycero- 3-phosphocholine (DPPC), 1,2-dipalmitoyl- sn -glycero- 3-phospho-(1′-rac-glycerol) (sodium salt) (DPPG), 1,2-dimyristoyl- sn -glycero- 3-phosphoethanolamine- N -[methoxy(polyethylene glycol)− 2000] (ammonium salt) (DMPE-PEG2000), 1,2-dipalmitoyl- sn -glycero- 3-phosphoethanolamine- N -(biotinyl) (sodium salt) (DPPE-biotin) and the extruder set were purchased from Avanti Polar Lipids (Alabaster, AL, USA); 1,2-dimyristoyl- sn -glycero- 3-phosphoethanolamine- N -[biotinyl(polyethylene glycol)− 2000] (DMPE-PEG2000-biotin) was purchased from Nanocs Inc. (USA); 1,2-dipalmitoyl- sn -glycero- 3-phosphoethanolamine- N -(glutaryl) (sodium salt) ( N -glutaryl-DPPE) from Coatsome; Cholesterol (≥ 99%, C8667), N -hydroxysulfosuccinimide sodium salt (sulfo-NHS) (≥ 98%, 56,485), hemin, hydrogen peroxide solution, potassium hexacyanoferrate(II) trihydrate (≥ 98.5%, P9387), hexaamineruthenium(III) chloride (RuHex) (262,005), 2-(2-Methoxyethoxy)ethanamine (901,159; PEG-amine), bovine serum albumin fraction V (BSA), polyclonal goat anti-biotin antibody (B3640), monoclonal rabbit anti-PEG antibody clone RM105 (MABS1214), monoclonal mouse anti-PEG clone 6.3 (MABS1966), Sephadex G- 50, and human complement serum (S1764) were purchased from Sigma-Aldrich/Merck (Darmstadt, Germany); Sulforhodamine B (SRB) (S1307), (1-ethyl- 3-(3-dimethylaminopropyl) carbodiimide-hydrochloride) (EDC) (PG82079), Nunc MaxiSorp high binding microplates (437,111), polyclonal goat anti-rabbit antibody (A16098), polyclonal rabbit anti-mouse antibody (A16162) and polyclonal donkey anti-goat antibody (A16001) were purchased from Thermo Fisher Scientific (Germany); n -Octyl-β- d -glucopyranoside (OG) (≥ 98%, CN23), 2-( N -morpholino)-ethane sulphonic acid (MES) (≥ 99%, 4259), calcium chloride dihydrate (≥ 99%, 5239) and N − 2-Hydroxyethylpiperazine- N ′− 2-ethane sulphonic acid (HEPES) (≥ 99.5%, HN78) from Carl Roth (Karlsruhe, Germany); DropSens screen-printed carbon electrodes were purchased from Metrohm Germany; m -carboxy luminol (purity: 73.6 ± 2.8 wt%) was custom-made by Taros Chemicals GmbH & Co. KG (Germany). .. Pooled Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum. Article Snippet: The phospholipids 1,2-dipalmitoyl-sn-glycero- 3-phosphocholine (DPPC), 1,2-dipalmitoyl-sn-glycero- 3-phospho-(1′-racglycerol) (sodium salt) (DPPG), 1,2-dimyristoyl-sn-glycero- 3-phosphoethanolamine-N-[methoxy(polyethylene glycol)− 2000] (ammonium salt) (DMPE-PEG2000), 1,2-dipalmitoyl-sn-glycero- 3-phosphoethanolamineN-(biotinyl) (sodium salt) (DPPE-biotin) and the extruder set were purchased from Avanti Polar Lipids (Alabaster, AL, USA); 1,2-dimyristoyl-sn-glycero- 3-phosphoethanolamineN-[biotinyl(polyethylene glycol)− 2000] (DMPE-PEG2000biotin) was purchased from Nanocs Inc. (USA); 1,2-dipalmitoyl-sn-glycero- 3-phosphoethanolamine-N-(glutaryl) (sodium salt) (N-glutaryl-DPPE) from Coatsome; Cholesterol (≥ 99%, C8667), N-hydroxysulfosuccinimide sodium salt (sulfo-NHS) (≥ 98%, 56,485), hemin, hydrogen peroxide solution, potassium hexacyanoferrate(II) trihydrate (≥ 98.5%, P9387), hexaamineruthenium(III) chloride (RuHex) (262,005), 2-(2-Methoxyethoxy)ethanamine (901,159; PEGamine), bovine serum albumin fraction V (BSA), polyclonal goat anti-biotin antibody (B3640), monoclonal rabbit antiPEG antibody clone RM105 (MABS1214), monoclonal mouse anti-PEG clone 6.3 (MABS1966), Sephadex G- 50, and human complement serum (S1764) were purchased from Sigma-Aldrich/Merck (Darmstadt, Germany); Sulforhodamine B (SRB) (S1307), (1-ethyl- 3-(3-dimethylaminopropyl) carbodiimide-hydrochloride) (EDC) (PG82079), Nunc MaxiSorp high binding microplates (437,111), polyclonal goat anti-rabbit antibody (A16098), polyclonal rabbit anti-mouse antibody (A16162) and polyclonal donkey anti-goat antibody (A16001) were purchased from Thermo Fisher Scientific (Germany); n-Octyl-β-d-glucopyranoside (OG) (≥ 98%, CN23), 2-(N-morpholino)-ethane sulphonic acid (MES) (≥ 99%, 4259), calcium chloride dihydrate (≥ 99%, 5239) and N− 2-Hydroxyethylpiperazine-N′− 2-ethane sulphonic acid (HEPES) (≥ 99.5%, HN78) from Carl Roth (Karlsruhe, Germany); DropSens screen-printed carbon electrodes were purchased from Metrohm Germany; m-carboxy luminol (purity: 73.6 ± 2.8 wt%) was custom-made by Taros Chemicals GmbH & Co. KG (Germany). .. Pooled other:Article Title: HPLC-UV Method Validation for Amobarbital and Pharmaceutical Stability Evaluation When Dispersed in a Hyaluronic Acid Hydrogel: A New Concept for Post-Traumatic Osteoarthritis Prevention. Article Snippet: HPLC sample measurements were made using an Agilent 1100 Series HPLC station coupled with a UV−vis diode array detector (Agilent Technologies, Santa Clara, CA). |