Review



high dna microarray scanner g2505c  (Agilent technologies)


Bioz Verified Symbol Agilent technologies is a verified supplier
Bioz Manufacturer Symbol Agilent technologies manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Agilent technologies high dna microarray scanner g2505c
    High Dna Microarray Scanner G2505c, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/pmc10500703-586-17-16
    Average 90 stars, based on 1 article reviews
    high dna microarray scanner g2505c - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Hybridization:

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis.
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization Conclusions In summary, our research revealed the protective roles of LINC01566 in clinical samples and cellular experiments, illustrating the potential roles and mechanism by which FOSL1/LINC01566 negatively regulates CD4 + T-cell activation in MG. Keywords lncRNA microarray chip, LINC01566, Bioinformatics analysis, CD4 + T cell, Myasthenia gravis and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Activation Assay:

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis.
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization Conclusions In summary, our research revealed the protective roles of LINC01566 in clinical samples and cellular experiments, illustrating the potential roles and mechanism by which FOSL1/LINC01566 negatively regulates CD4 + T-cell activation in MG. Keywords lncRNA microarray chip, LINC01566, Bioinformatics analysis, CD4 + T cell, Myasthenia gravis and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Microarray:

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis.
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization Conclusions In summary, our research revealed the protective roles of LINC01566 in clinical samples and cellular experiments, illustrating the potential roles and mechanism by which FOSL1/LINC01566 negatively regulates CD4 + T-cell activation in MG. Keywords lncRNA microarray chip, LINC01566, Bioinformatics analysis, CD4 + T cell, Myasthenia gravis and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Article Title: Potential Diagnostic Biomarkers of tRNA-Derived Small RNAs in PBMCs for Nonproliferative Diabetic Retinopathy in Patients With Type 2 Diabetes Mellitus.
    Article Snippet: .. The slides were scanned on an Agilent G2505C microarray scanner. .. The acquired array images were analyzed using Agilent Feature Extraction software (version 11.0.1.1).

    Article Title: A network-based trans-omics approach for predicting synergistic drug combinations
    Article Snippet: After hybridization, microarrays were washed for 1 min at room temperature with GE Wash Buffer 1 (Agilent) and 1 min at 37 °C with GE Wash Buffer 2 (Agilent), then dried immediately. .. The slides were scanned immediately after washing using an Agilent DNA Microarray Scanner (G2505C) with a one-color scan setting for 8 × 60 K array slides (Scan Area 61 × 21.6 mm, Scan resolution 3 μm, Dye channel was set to Green and Green PMT was set to 100%). .. The scanned images were analyzed with Feature Extraction Software 10.7.1.1 (Agilent) using default parameters (protocol GE1_107_Sep09 and Grid: 028282_D_F_20110531) to obtain background subtracted and spatially detrended processed signal intensities.

    Extraction:

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis.
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization Conclusions In summary, our research revealed the protective roles of LINC01566 in clinical samples and cellular experiments, illustrating the potential roles and mechanism by which FOSL1/LINC01566 negatively regulates CD4 + T-cell activation in MG. Keywords lncRNA microarray chip, LINC01566, Bioinformatics analysis, CD4 + T cell, Myasthenia gravis and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Software:

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis.
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization Conclusions In summary, our research revealed the protective roles of LINC01566 in clinical samples and cellular experiments, illustrating the potential roles and mechanism by which FOSL1/LINC01566 negatively regulates CD4 + T-cell activation in MG. Keywords lncRNA microarray chip, LINC01566, Bioinformatics analysis, CD4 + T cell, Myasthenia gravis and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.

    Article Title: FOSL1-mediated LINC01566 negatively regulates CD4 + T-cell activation in myasthenia gravis
    Article Snippet: The labeled cDNAs were hybridized onto the Human LncRNA Array, version 5.0 (8 × 60 K, Arraystar). .. After hybridization and washing, the arrays were scanned using an Agilent G2505C scanner and Agilent Feature Extraction software, version 11.1, to analyze the acquired array images. .. Quantile normalization and subsequent data processing were performed using Agilent GeneSpring GX software, version 12.1.



    Similar Products

    90
    Agilent technologies surescan high-resolution dna microarray scanner
    Flow chart of <t>microarray</t> data analysis. The agilent single color microarray platform was used having more than 58,000 transcripts and further data processing was done using agilent GeneSpring software followed by pathway analysis using GSEA database. Numbers in parentheses illustrates number of pathways enriched in each category using GSEA database. DEGs-Differentially expressed genes, ANOVA-Analysis of variance, BP-Biological pathway, CC-Cellular component, MF-Molecular function.
    Surescan High Resolution Dna Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/bio_rxiv__2024__06__24__600143-52-12-11
    Average 90 stars, based on 1 article reviews
    surescan high-resolution dna microarray scanner - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    86
    Innopsys Inc innoscan 710 high resolution microarray scanner
    Flow chart of <t>microarray</t> data analysis. The agilent single color microarray platform was used having more than 58,000 transcripts and further data processing was done using agilent GeneSpring software followed by pathway analysis using GSEA database. Numbers in parentheses illustrates number of pathways enriched in each category using GSEA database. DEGs-Differentially expressed genes, ANOVA-Analysis of variance, BP-Biological pathway, CC-Cellular component, MF-Molecular function.
    Innoscan 710 High Resolution Microarray Scanner, supplied by Innopsys Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/710al+innopsys+scanner/pmc13207355-405-10-15
    Average 86 stars, based on 1 article reviews
    innoscan 710 high resolution microarray scanner - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    90
    Innopsys Inc innoscan 710 high-resolution microarray scanner
    Flow chart of <t>microarray</t> data analysis. The agilent single color microarray platform was used having more than 58,000 transcripts and further data processing was done using agilent GeneSpring software followed by pathway analysis using GSEA database. Numbers in parentheses illustrates number of pathways enriched in each category using GSEA database. DEGs-Differentially expressed genes, ANOVA-Analysis of variance, BP-Biological pathway, CC-Cellular component, MF-Molecular function.
    Innoscan 710 High Resolution Microarray Scanner, supplied by Innopsys Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/innoscan+300+microarray+scanner/bio_rxiv__2024__11__27__625719-220-7-12
    Average 90 stars, based on 1 article reviews
    innoscan 710 high-resolution microarray scanner - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies high-resolution microarray scanner
    The 11 genes were detected in the <t>microarray</t> analysis and in the human dataset. A correlation between FCs of genes. B heatmap with hierarchical clustering of FCs of the 11 genes commonly detected in the murine neurospheres and AD patients’ tissues
    High Resolution Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/pmc11184896-52-18-21
    Average 90 stars, based on 1 article reviews
    high-resolution microarray scanner - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies g2565ca high-resolution laser microarray scanner
    The 11 genes were detected in the <t>microarray</t> analysis and in the human dataset. A correlation between FCs of genes. B heatmap with hierarchical clustering of FCs of the 11 genes commonly detected in the murine neurospheres and AD patients’ tissues
    G2565ca High Resolution Laser Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/pmc11092345-332-15-20
    Average 90 stars, based on 1 article reviews
    g2565ca high-resolution laser microarray scanner - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies high dna microarray scanner g2505c
    The 11 genes were detected in the <t>microarray</t> analysis and in the human dataset. A correlation between FCs of genes. B heatmap with hierarchical clustering of FCs of the 11 genes commonly detected in the murine neurospheres and AD patients’ tissues
    High Dna Microarray Scanner G2505c, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/high+microarray+scanner/pmc10500703-586-17-16
    Average 90 stars, based on 1 article reviews
    high dna microarray scanner g2505c - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Flow chart of microarray data analysis. The agilent single color microarray platform was used having more than 58,000 transcripts and further data processing was done using agilent GeneSpring software followed by pathway analysis using GSEA database. Numbers in parentheses illustrates number of pathways enriched in each category using GSEA database. DEGs-Differentially expressed genes, ANOVA-Analysis of variance, BP-Biological pathway, CC-Cellular component, MF-Molecular function.

    Journal: bioRxiv

    Article Title: Synovial fluid transcriptome dynamics in osteoarthritis progression: Implications in pathogenesis

    doi: 10.1101/2024.06.24.600143

    Figure Lengend Snippet: Flow chart of microarray data analysis. The agilent single color microarray platform was used having more than 58,000 transcripts and further data processing was done using agilent GeneSpring software followed by pathway analysis using GSEA database. Numbers in parentheses illustrates number of pathways enriched in each category using GSEA database. DEGs-Differentially expressed genes, ANOVA-Analysis of variance, BP-Biological pathway, CC-Cellular component, MF-Molecular function.

    Article Snippet: Following hybridization, the array slides were washed and scanned with an Agilent SureScan High-Resolution DNA Microarray Scanner.

    Techniques: Microarray, Software

    The 11 genes were detected in the microarray analysis and in the human dataset. A correlation between FCs of genes. B heatmap with hierarchical clustering of FCs of the 11 genes commonly detected in the murine neurospheres and AD patients’ tissues

    Journal: Cell & Bioscience

    Article Title: Bradykinin promotes immune responses in differentiated embryonic neurospheres carrying APP swe and PS1 dE9 mutations

    doi: 10.1186/s13578-024-01251-3

    Figure Lengend Snippet: The 11 genes were detected in the microarray analysis and in the human dataset. A correlation between FCs of genes. B heatmap with hierarchical clustering of FCs of the 11 genes commonly detected in the murine neurospheres and AD patients’ tissues

    Article Snippet: The arrays were then washed as described on Agilent SSPE wash protocol v. 2.1 and scanned with a High-Resolution Microarray Scanner (Agilent Technologies).

    Techniques: Microarray