Review



adaptive thresholding method  (MathWorks Inc)


Bioz Verified Symbol MathWorks Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    MathWorks Inc adaptive thresholding method
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Thresholding Method, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pmc12145992-149-9-5
    Average 90 stars, based on 1 article reviews
    adaptive thresholding method - by Bioz Stars, 2026-09
    90/100 stars

    Images

    1) Product Images from "High-speed imaging and coumarin dosimetry of horn type ultrasonic reactors: Influence of probe diameter and amplitude"

    Article Title: High-speed imaging and coumarin dosimetry of horn type ultrasonic reactors: Influence of probe diameter and amplitude

    Journal: Ultrasonics Sonochemistry

    doi: 10.1016/j.ultsonch.2025.107362

    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive thresholding method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Figure Legend Snippet: Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive thresholding method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.

    Techniques Used: Sequencing

    Related Articles

    other:

    Article Title: CLCa mediates a novel cross-talk between Wnt secretion and actin organization.
    Article Snippet: Further analysis was done using custom-written scripts in MATLAB, where an adaptive thresholding method was used with a sensitivity of 0.2.

    Bacteria:

    Article Title:
    Article Snippet: Sample information for TIFF files were imported into a MATLAB table, including sample information, dilution, and whether mannose was included. .. We binarized each .tif file via MATLAB’s adaptive thresholding, using thresholding values of 0.4 for both mCherry (bacteria) and ymCitrine (yeast). .. Binarized contiguous events were made solid by “filling” regions, and region properties were calculated via MATLAB’s regionprops function: for yeast, event areas and bounding boxes (minimum quadrangle that would fit event); for bacteria, centroids (center coordinates of each event).



    Similar Products

    90
    Axion BioSystems spike detector with adaptive thresholding
    Spike Detector With Adaptive Thresholding, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/spike+detector+with+adaptive+thresholding/pmc12277964-93-10-30
    Average 90 stars, based on 1 article reviews
    spike detector with adaptive thresholding - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc adaptive thresholding method
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Thresholding Method, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pmc12145992-149-9-5
    Average 90 stars, based on 1 article reviews
    adaptive thresholding method - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc adaptive thresholding
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Thresholding, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pmc11326116__msystems__00050___24___s0001-22-7-6
    Average 90 stars, based on 1 article reviews
    adaptive thresholding - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc adaptive thresholding matlab function
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Thresholding Matlab Function, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pmc12106601-673-11-13
    Average 90 stars, based on 1 article reviews
    adaptive thresholding matlab function - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc adaptive thresholding matlab function adaptthresh
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Thresholding Matlab Function Adaptthresh, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pm40419471-687-11-13
    Average 90 stars, based on 1 article reviews
    adaptive thresholding matlab function adaptthresh - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc adaptive threshold mask of mr image
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Threshold Mask Of Mr Image, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pmc11920253-63-41-45
    Average 90 stars, based on 1 article reviews
    adaptive threshold mask of mr image - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc matlab's built-in adaptive thresholding
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Matlab's Built In Adaptive Thresholding, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pm39817858-359-15-13
    Average 90 stars, based on 1 article reviews
    matlab's built-in adaptive thresholding - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc adaptive threshold matlab function adaptthresh
    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive <t>thresholding</t> method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.
    Adaptive Threshold Matlab Function Adaptthresh, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/adaptive+thresholding/pm39856404-252-27-27
    Average 90 stars, based on 1 article reviews
    adaptive threshold matlab function adaptthresh - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive thresholding method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.

    Journal: Ultrasonics Sonochemistry

    Article Title: High-speed imaging and coumarin dosimetry of horn type ultrasonic reactors: Influence of probe diameter and amplitude

    doi: 10.1016/j.ultsonch.2025.107362

    Figure Lengend Snippet: Image process for a 7 mm probe with a nominal amplitude of 70%: (a) Cropped image (grayscale frame from the recorded video); (b) binarized image using the adaptive thresholding method; (c) binarized image using Otsu’s method; (d) final binary image obtained using a hybrid procedure of the two methods; (e) total vapor amount over time from the high-speed image sequence. The unit of measure of the y -axis is mm 2 since the backlighting visualization provides a 2D representation of the vapor phase.

    Article Snippet: Two different functions available on Matlab were used: the adaptive thresholding method and the Otsu’s method , .

    Techniques: Sequencing