creatinine abbott jaffe method (Abbott Laboratories)
Structured Review

Creatinine Abbott Jaffe Method, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/abbott+jaffe+method/creatinine++jaffe/pmc08620133-175-40-40
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "A simplified, rapid LC-MS/MS assay for serum and salivary creatinine"
Article Title: A simplified, rapid LC-MS/MS assay for serum and salivary creatinine
Journal: Clinical Mass Spectrometry
doi: 10.1016/j.clinms.2018.11.004
Figure Legend Snippet: Method comparison between a kinetic alkaline picrate assay (Abbott Architect c16000 analyser) and the LC-MS/MS assay using 20 anonymised surplus serum samples. (A) Deming regression analysis of LC-MS/MS creatinine plotted against the Abbott Jaffe creatinine result. (B) Bland Altman (difference) plot illustrating the agreement between the two methods. Average bias and 95% limits of agreement are shown.
Techniques Used: Comparison, Liquid Chromatography with Mass Spectroscopy
Figure Legend Snippet: Effect of glucose on measured creatinine. (A) Pooled serum was spiked with glucose to provide a range of concentrations. Glucose was measured using a hexokinase enzymatic assay and creatinine was analysed using both the Abbott Architect Jaffe method and by LC-MS/MS. The percentage change in measured creatinine compared to the unspiked sample was calculated for both creatinine methods. (B) Fifteen patient samples with high concentrations of endogenous glucose were analysed for creatinine by both assays and the % difference between the Abbott Jaffe method and the LC-MS/MS assay is shown for each sample.
Techniques Used: Enzymatic Assay, Liquid Chromatography with Mass Spectroscopy
Figure Legend Snippet: Effect of bilirubin on measured creatinine. Five serum samples were spiked with bilirubin in DMSO or with DMSO alone, and the bilirubin concentration and icteric index were measured on an Abbott Architect analyser. Abbott Jaffe creatinine and LC-MS/MS creatinine values are plotted against icteric index (A, C) or measured bilirubin (B, D).
Techniques Used: Concentration Assay, Liquid Chromatography with Mass Spectroscopy
Related Articles
other:Article Title: Metabolic Risk Factors in Patients with Kidney Stones with and without Type 2 Diabetes Article Snippet: Both serum and urine creatinine (Jaffe) and phosphate (UV) were measured using an automated Concentration Assay:Article Title: Quantitative justification for target concentration intervention - parameter variability and predictive performance using population pharmacokinetic models for aminoglycosides Article Snippet: .. Serum creatinine concentration was measured using a |
