Review



244 k microarrays  (Agilent technologies)


Bioz Verified Symbol Agilent technologies is a verified supplier
Bioz Manufacturer Symbol Agilent technologies manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Agilent technologies 244 k microarrays
    244 K Microarrays, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pm37048158-31-17-16
    Average 90 stars, based on 1 article reviews
    244 k microarrays - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Incubation:

    Article Title: A randomized translational study on protein- and glucose metabolism in skeletal muscles evaluated by gene-ontology, following preoperative oral carbohydrate loading compared to overnight peripheral parenteral nutrition (PPN) before major cancer surgery.
    Article Snippet: .. Samples were hybridized to Agilent SurePrint G3 Human GE v3 8 × 60 K Microarrays and incubated under rotation at 65 °C for 17 h. After hybridization, arrays were washed according to manufacturer’s protocol and immediately scanned using Agilent DNA microarray scanner G2505C at 3 μm resolution (Agilent Technologies). .. The fluorescent intensities of scanned images were extracted and preprocessed with the Agilent Feature Extraction Software (version 10.7.3.1).

    Hybridization:

    Article Title: A randomized translational study on protein- and glucose metabolism in skeletal muscles evaluated by gene-ontology, following preoperative oral carbohydrate loading compared to overnight peripheral parenteral nutrition (PPN) before major cancer surgery.
    Article Snippet: .. Samples were hybridized to Agilent SurePrint G3 Human GE v3 8 × 60 K Microarrays and incubated under rotation at 65 °C for 17 h. After hybridization, arrays were washed according to manufacturer’s protocol and immediately scanned using Agilent DNA microarray scanner G2505C at 3 μm resolution (Agilent Technologies). .. The fluorescent intensities of scanned images were extracted and preprocessed with the Agilent Feature Extraction Software (version 10.7.3.1).

    Microarray:

    Article Title: A randomized translational study on protein- and glucose metabolism in skeletal muscles evaluated by gene-ontology, following preoperative oral carbohydrate loading compared to overnight peripheral parenteral nutrition (PPN) before major cancer surgery.
    Article Snippet: .. Samples were hybridized to Agilent SurePrint G3 Human GE v3 8 × 60 K Microarrays and incubated under rotation at 65 °C for 17 h. After hybridization, arrays were washed according to manufacturer’s protocol and immediately scanned using Agilent DNA microarray scanner G2505C at 3 μm resolution (Agilent Technologies). .. The fluorescent intensities of scanned images were extracted and preprocessed with the Agilent Feature Extraction Software (version 10.7.3.1).

    Comparison:

    Article Title: Sex disparities in non-small cell lung cancer: mechanistic insights from a cRaf transgenic disease model.
    Article Snippet: .. A crossplatform comparison of affymetrix and Agilent microarrays reveals discordant miRNA expression in lung tumors of c-Raf transgenic mice. ..

    Expressing:

    Article Title: Sex disparities in non-small cell lung cancer: mechanistic insights from a cRaf transgenic disease model.
    Article Snippet: .. A crossplatform comparison of affymetrix and Agilent microarrays reveals discordant miRNA expression in lung tumors of c-Raf transgenic mice. ..

    Transgenic Assay:

    Article Title: Sex disparities in non-small cell lung cancer: mechanistic insights from a cRaf transgenic disease model.
    Article Snippet: .. A crossplatform comparison of affymetrix and Agilent microarrays reveals discordant miRNA expression in lung tumors of c-Raf transgenic mice. ..

    Gene Expression:

    Article Title: Endogenous ZAP is associated with altered global cellular gene expression during Zika virus infection
    Article Snippet: .. Specifically, global gene expression analysis with Agilent microarrays revealed 1,065 upregulated and 776 downregulated transcripts in uninfected wild-type and ZAP-KO HeLa cells [ ]. ..

    Article Title: A non-canonical role of ELN protects from cellular senescence by limiting iron-dependent regulation of gene expression.
    Article Snippet: .. Transcriptomic analysis was performed using Whole Human Genome Oligo 4 × 44 K Microarrays (Agilent Technologies) and Agilent singlecolor gene expression workflow. .. First RNA was extracted using Nucleospin RNA (Macherey Nagel) and quality (RNA integrity number – RIN) was tested with 2200 TapeStation system (Agilent technology). cRNA was synthesized and labeled with Cy3 dye from 100 ng of total RNA using a single-color Low Input Quick Amp Labeling Kit (Agilent Technologies).

    other:

    Article Title: Potential therapeutic implications of histidine catabolism by the gut microbiota in NAFLD patients with morbid obesity
    Article Snippet: cRNA was prepared by amplification of the RNA and labeled with Cy3 using the Agilent Low Input Quick Amp Labeling Kit according to the manufacturer’s instructions.



    Similar Products

    90
    Agilent technologies sureprint g3 mouse cgh 244 k microarray kit
    Sureprint G3 Mouse Cgh 244 K Microarray Kit, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pmc11076575-328-20-22
    Average 90 stars, based on 1 article reviews
    sureprint g3 mouse cgh 244 k microarray kit - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies custom 244 k whole genome microarray data
    Custom 244 K Whole Genome Microarray Data, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pmc11265146-109-0-3
    Average 90 stars, based on 1 article reviews
    custom 244 k whole genome microarray data - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies 244 k cpg island microarray chip
    244 K Cpg Island Microarray Chip, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pm37018893-65-22-26
    Average 90 stars, based on 1 article reviews
    244 k cpg island microarray chip - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies 244 k microarrays
    244 K Microarrays, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pm37048158-31-17-16
    Average 90 stars, based on 1 article reviews
    244 k microarrays - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies 244 k microarray
    244 K Microarray, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pm37002329-55-6-7
    Average 90 stars, based on 1 article reviews
    244 k microarray - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies 244 k microarray data
    a TCGA matched samples (520 from BRCA, 150 from GBM) run on both <t>microarray</t> and RNA-seq were split into a training set (2/3) and test set (1/3). b RNA-seq samples were titrated into each training set, 10% at a time (0–100%), resulting in eleven training sets for each normalization method. Each RNA-seq sample replaces its matched microarray sample. Cross-platform normalization methods were applied to each training set independently. c We used three supervised algorithms to train classifiers (molecular subtype and mutation status of TP53 and PIK3CA in both BRCA and GBM) on each training set and tested on the microarray and RNA-seq test sets. The test sets were projected onto and back out of the training set space using unsupervised Principal Components Analysis to obtain reconstructed test sets. The subtype classifiers trained in step 3A were used to predict on the reconstructed test sets. Pathways regulating gene expression were identified using the unsupervised method PLIER.
    244 K Microarray Data, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pmc09968332-141-17-14
    Average 90 stars, based on 1 article reviews
    244 k microarray data - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Agilent technologies comparative genomic hybridization 244 k microarrays
    a TCGA matched samples (520 from BRCA, 150 from GBM) run on both <t>microarray</t> and RNA-seq were split into a training set (2/3) and test set (1/3). b RNA-seq samples were titrated into each training set, 10% at a time (0–100%), resulting in eleven training sets for each normalization method. Each RNA-seq sample replaces its matched microarray sample. Cross-platform normalization methods were applied to each training set independently. c We used three supervised algorithms to train classifiers (molecular subtype and mutation status of TP53 and PIK3CA in both BRCA and GBM) on each training set and tested on the microarray and RNA-seq test sets. The test sets were projected onto and back out of the training set space using unsupervised Principal Components Analysis to obtain reconstructed test sets. The subtype classifiers trained in step 3A were used to predict on the reconstructed test sets. Pathways regulating gene expression were identified using the unsupervised method PLIER.
    Comparative Genomic Hybridization 244 K Microarrays, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/244+k+microarray/pmc04053776-329-11-12
    Average 90 stars, based on 1 article reviews
    comparative genomic hybridization 244 k microarrays - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    a TCGA matched samples (520 from BRCA, 150 from GBM) run on both microarray and RNA-seq were split into a training set (2/3) and test set (1/3). b RNA-seq samples were titrated into each training set, 10% at a time (0–100%), resulting in eleven training sets for each normalization method. Each RNA-seq sample replaces its matched microarray sample. Cross-platform normalization methods were applied to each training set independently. c We used three supervised algorithms to train classifiers (molecular subtype and mutation status of TP53 and PIK3CA in both BRCA and GBM) on each training set and tested on the microarray and RNA-seq test sets. The test sets were projected onto and back out of the training set space using unsupervised Principal Components Analysis to obtain reconstructed test sets. The subtype classifiers trained in step 3A were used to predict on the reconstructed test sets. Pathways regulating gene expression were identified using the unsupervised method PLIER.

    Journal: Communications Biology

    Article Title: Cross-platform normalization enables machine learning model training on microarray and RNA-seq data simultaneously

    doi: 10.1038/s42003-023-04588-6

    Figure Lengend Snippet: a TCGA matched samples (520 from BRCA, 150 from GBM) run on both microarray and RNA-seq were split into a training set (2/3) and test set (1/3). b RNA-seq samples were titrated into each training set, 10% at a time (0–100%), resulting in eleven training sets for each normalization method. Each RNA-seq sample replaces its matched microarray sample. Cross-platform normalization methods were applied to each training set independently. c We used three supervised algorithms to train classifiers (molecular subtype and mutation status of TP53 and PIK3CA in both BRCA and GBM) on each training set and tested on the microarray and RNA-seq test sets. The test sets were projected onto and back out of the training set space using unsupervised Principal Components Analysis to obtain reconstructed test sets. The subtype classifiers trained in step 3A were used to predict on the reconstructed test sets. Pathways regulating gene expression were identified using the unsupervised method PLIER.

    Article Snippet: For BRCA (520 pairs of matched samples), we used log 2 -transformed, lowess normalized Agilent 244 K microarray data and RSEM (RNA-seq by Expectation Maximization) gene-level count RNA-seq data .

    Techniques: Microarray, RNA Sequencing Assay, Mutagenesis, Expressing