Review



sigmoidal, 4pl model of regression analysis  (GraphPad Software Inc)


Bioz Verified Symbol GraphPad Software Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    GraphPad Software Inc sigmoidal, 4pl model of regression analysis
    Sigmoidal, 4pl Model Of Regression Analysis, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal++4pl+model+of+regression+analysis/pmc10293842__pnas__2303292120__sapp-66-12-17
    Average 90 stars, based on 1 article reviews
    sigmoidal, 4pl model of regression analysis - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    Concentration Assay:

    Article Title: Structural basis and synergism of ATP and Na + activation in bacterial K + uptake system KtrAB
    Article Snippet: .. The unfolding concentration (C m ) of urea was analyzed using Sigmoidal 4PL model by GraphPad Prism. ..

    Software:

    Article Title: Cranberry ( Vaccinium macrocarpon ) Extract Impairs Nairovirus Infection by Inhibiting the Attachment to Target Cells
    Article Snippet: .. Curve fitting was performed to determine EC 50 values using a sigmoidal 4PL model in GraphPad Prism 8 software. ..



    Similar Products

    90
    GraphPad Software Inc sigmoidal, 4pl model of regression analysis
    Sigmoidal, 4pl Model Of Regression Analysis, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal++4pl+model+of+regression+analysis/pmc10293842__pnas__2303292120__sapp-66-12-17
    Average 90 stars, based on 1 article reviews
    sigmoidal, 4pl model of regression analysis - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    GraphPad Software Inc sigmoidal, 4pl model in graphpad prism 9
    Sigmoidal, 4pl Model In Graphpad Prism 9, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal++4pl+model+of+regression+analysis/pm39939761-761-7-9
    Average 90 stars, based on 1 article reviews
    sigmoidal, 4pl model in graphpad prism 9 - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    GraphPad Software Inc sigmoidal, 4pl model
    Sigmoidal, 4pl Model, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal++4pl+model+of+regression+analysis/pm39939761-754-7-9
    Average 90 stars, based on 1 article reviews
    sigmoidal, 4pl model - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    GraphPad Software Inc pre-set sigmoidal models: 4pl
    Pre Set Sigmoidal Models: 4pl, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal+4pl/pm39259728-470-6-5
    Average 90 stars, based on 1 article reviews
    pre-set sigmoidal models: 4pl - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    GraphPad Software Inc pre-set sigmoidal models 4-parameter logistic (4pl) model
    Pre Set Sigmoidal Models 4 Parameter Logistic (4pl) Model, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/pre+set+sigmoidal+models+4+parameter+logistic++4pl++model/pmc11196219-491-13-10
    Average 90 stars, based on 1 article reviews
    pre-set sigmoidal models 4-parameter logistic (4pl) model - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    GraphPad Software Inc sigmoidal 4pl model
    a , b Left panels: intrinsic tryptophan fluorescence-based urea unfolding assays of ATP-BsKtrA in ( a ) K + Buffer titrated against NaCl and in ( b ) Na + Buffer titrated against KCl, respectively. Right panels: the C m values plotted against [Na + ] and [K + ], respectively. The C m values were calculated by fitting the data to a sigmoidal <t>4PL</t> model using GraphPad Prism. Refer to Supplementary Fig. for original fluorescence data. c , d Differential scanning fluorimetry (DSF) assays demonstrating the T m of ( c ) ATP-BsKtrA and ( d ) ATP-BsKtrA E125Q titrated with NaCl (blue bars) and KCl (green bars). Data represent the mean ± s.d. with ( c ) n = 6 and ( d ) n = 4 independent experimental replicates. Inset c , the apparent dissociation constant ( K dapp ) of Na + binding with ATP-BsKtrA. The K dapp was analyzed by fitting the fraction bound derived from the DSF assays against the concentrations of NaCl to a one-site model using GraphPad Prism. Refer to Supplementary Fig. for raw data. e Half-life constants of BsKtrA in the presence of Na + (blue bars) and K + (green bars). The half-life constants were determined by GraphPad Prism using exponential one-phase decay model. Data represent the mean ± s.d.; n = 4 independent experimental replicates. Statistical analyses were performed using two-way ANOVA. Refer to Supplementary Fig. for raw data. Source data for a – e are provided as a Source Data file.
    Sigmoidal 4pl Model, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal++4pl+model+of+regression+analysis/pmc11078986-98-12-16
    Average 90 stars, based on 1 article reviews
    sigmoidal 4pl model - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    GraphPad Software Inc non-linear regression model sigmoidal 4pl
    a , b Left panels: intrinsic tryptophan fluorescence-based urea unfolding assays of ATP-BsKtrA in ( a ) K + Buffer titrated against NaCl and in ( b ) Na + Buffer titrated against KCl, respectively. Right panels: the C m values plotted against [Na + ] and [K + ], respectively. The C m values were calculated by fitting the data to a sigmoidal <t>4PL</t> model using GraphPad Prism. Refer to Supplementary Fig. for original fluorescence data. c , d Differential scanning fluorimetry (DSF) assays demonstrating the T m of ( c ) ATP-BsKtrA and ( d ) ATP-BsKtrA E125Q titrated with NaCl (blue bars) and KCl (green bars). Data represent the mean ± s.d. with ( c ) n = 6 and ( d ) n = 4 independent experimental replicates. Inset c , the apparent dissociation constant ( K dapp ) of Na + binding with ATP-BsKtrA. The K dapp was analyzed by fitting the fraction bound derived from the DSF assays against the concentrations of NaCl to a one-site model using GraphPad Prism. Refer to Supplementary Fig. for raw data. e Half-life constants of BsKtrA in the presence of Na + (blue bars) and K + (green bars). The half-life constants were determined by GraphPad Prism using exponential one-phase decay model. Data represent the mean ± s.d.; n = 4 independent experimental replicates. Statistical analyses were performed using two-way ANOVA. Refer to Supplementary Fig. for raw data. Source data for a – e are provided as a Source Data file.
    Non Linear Regression Model Sigmoidal 4pl, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sigmoidal+4pl+model/sigmoidal++4pl+model+of+regression+analysis/pmc10705807-58-15-36
    Average 90 stars, based on 1 article reviews
    non-linear regression model sigmoidal 4pl - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    a , b Left panels: intrinsic tryptophan fluorescence-based urea unfolding assays of ATP-BsKtrA in ( a ) K + Buffer titrated against NaCl and in ( b ) Na + Buffer titrated against KCl, respectively. Right panels: the C m values plotted against [Na + ] and [K + ], respectively. The C m values were calculated by fitting the data to a sigmoidal 4PL model using GraphPad Prism. Refer to Supplementary Fig. for original fluorescence data. c , d Differential scanning fluorimetry (DSF) assays demonstrating the T m of ( c ) ATP-BsKtrA and ( d ) ATP-BsKtrA E125Q titrated with NaCl (blue bars) and KCl (green bars). Data represent the mean ± s.d. with ( c ) n = 6 and ( d ) n = 4 independent experimental replicates. Inset c , the apparent dissociation constant ( K dapp ) of Na + binding with ATP-BsKtrA. The K dapp was analyzed by fitting the fraction bound derived from the DSF assays against the concentrations of NaCl to a one-site model using GraphPad Prism. Refer to Supplementary Fig. for raw data. e Half-life constants of BsKtrA in the presence of Na + (blue bars) and K + (green bars). The half-life constants were determined by GraphPad Prism using exponential one-phase decay model. Data represent the mean ± s.d.; n = 4 independent experimental replicates. Statistical analyses were performed using two-way ANOVA. Refer to Supplementary Fig. for raw data. Source data for a – e are provided as a Source Data file.

    Journal: Nature Communications

    Article Title: Structural basis and synergism of ATP and Na + activation in bacterial K + uptake system KtrAB

    doi: 10.1038/s41467-024-48057-y

    Figure Lengend Snippet: a , b Left panels: intrinsic tryptophan fluorescence-based urea unfolding assays of ATP-BsKtrA in ( a ) K + Buffer titrated against NaCl and in ( b ) Na + Buffer titrated against KCl, respectively. Right panels: the C m values plotted against [Na + ] and [K + ], respectively. The C m values were calculated by fitting the data to a sigmoidal 4PL model using GraphPad Prism. Refer to Supplementary Fig. for original fluorescence data. c , d Differential scanning fluorimetry (DSF) assays demonstrating the T m of ( c ) ATP-BsKtrA and ( d ) ATP-BsKtrA E125Q titrated with NaCl (blue bars) and KCl (green bars). Data represent the mean ± s.d. with ( c ) n = 6 and ( d ) n = 4 independent experimental replicates. Inset c , the apparent dissociation constant ( K dapp ) of Na + binding with ATP-BsKtrA. The K dapp was analyzed by fitting the fraction bound derived from the DSF assays against the concentrations of NaCl to a one-site model using GraphPad Prism. Refer to Supplementary Fig. for raw data. e Half-life constants of BsKtrA in the presence of Na + (blue bars) and K + (green bars). The half-life constants were determined by GraphPad Prism using exponential one-phase decay model. Data represent the mean ± s.d.; n = 4 independent experimental replicates. Statistical analyses were performed using two-way ANOVA. Refer to Supplementary Fig. for raw data. Source data for a – e are provided as a Source Data file.

    Article Snippet: The C m values were calculated by fitting the data to a sigmoidal 4PL model using GraphPad Prism.

    Techniques: Fluorescence, Binding Assay, Derivative Assay