Review



alkaline phosphatase seap reporter assay raw blue cells  (InvivoGen)


Bioz Verified Symbol InvivoGen is a verified supplier
Bioz Manufacturer Symbol InvivoGen manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    InvivoGen alkaline phosphatase seap reporter assay raw blue cells
    Alkaline Phosphatase Seap Reporter Assay Raw Blue Cells, supplied by InvivoGen, used in various techniques. Bioz Stars score: 96/100, based on 291 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/RAW-Blue+cells/us12655429-1771-3-21
    Average 96 stars, based on 291 article reviews
    alkaline phosphatase seap reporter assay raw blue cells - by Bioz Stars, 2026-10
    96/100 stars

    Images

    Related Articles

    other:

    Article Title: Compositions and methods for delivery of nucleic acids to cells
    Article Snippet: RIG-I reporter cells (HEK-Lucia RIG-I, Invivogen) were seeded at 50,000 cells per well and treated with RIG-I ligands (1 ug) or ligands complexed to 3E10-D31N (20 ug).

    Article Title: Click-to-Release for Controlled Immune Cell Activation: Tumor-Targeted Unmasking of an IL12 Prodrug
    Article Snippet: Next, a 1:2-step dilution was made, after which 80.000 reporter cells (HEK-Blue IL12 cells; InvivoGen) were added in complete medium containing 10% FCS.

    Activity Assay:

    Article Title: Development of Bispecific Antibody Targeting Human IL-17A and IL-6
    Article Snippet: The binding data were analyzed with the ForteBio data analysis software HT 10.0, and affinity constants (KD) were calculated using a 1:1 interaction model (fitting global). .. HEK-Blue IL-6 (#hkb-il6; InvivoGen, San Diego, CA, USA) or HEK-Blue IL-17 (#hkb-il17; InvivoGen) reporter cells were used to assess the biological activity of VHHs. .. Cells were stimulated with IL-6 (1 ng/mL; PeproTech Inc., Rocky Hill, NJ, USA) and IL-17A (10 ng/mL; ACROBiosystems, Newark, DE, USA) in the presence of various concentrations of each VHH, ranging from 0.3 nM to 600 nM for IL-6 and from 0.003 nM to 100 nM for IL-17A.

    Selection:

    Article Title: Gut microbiota-derived GlcNAc-MurNAc is a TLR4 agonist that protects the host gut.
    Article Snippet: THP-1 cells were maintained in Roswell Park Memorial Institute 1640 (RPMI 1640, Gibco). .. All reporter cells (HEK-BlueTM mTLR4 / mTLR2 / Null1 / Null2 / hNod1 / hNod2 cells, RAW-DualTM and RAW-DualTM Tlr4-/- cells) were grown in high-glucose DMEM supplemented with 100 μg/mL Normocin (InvivoGen) and selection antibiotics as required. .. Specifically, HEKBlueTM Null1 and Null2 cells were selected under 100 μg/mL Zeocin (InvivoGen); HEK-BlueTM hNod1 and hNod2 cells were selected under 100 μg/mL Zeocin (InvivoGen) and 30 μg/mL Blasticidin (InvivoGen); HEK-BlueTM mTLR4 and mTLR2 cells were supplemented with 1× HEKBlueTM Selection (InvivoGen).

    Cell Culture:

    Article Title: SdiA as a Repressor of Phagocytosis and Intracellular Survival in Klebsiella pneumoniae : Insights from Macrophage and Amoeba Models
    Article Snippet: .. THP1-Dual reporter cells (InvivoGen, cat. no. thpd-nfis) were cultured in Roswell Park Memorial Institute (RPMI) 1640 Medium (Gibco 21875) supplemented with 10 % heat-inactivated fetal calf serum, 10 mM HEPES (Sigma), 100 U/ml penicillin, and 0.1 mg/ml streptomycin (Gibco). ..

    Incubation:

    Article Title: CD4 T-cell platform for delivering interferons as an antiviral countermeasure with a focus on SARS-CoV-2
    Article Snippet: .. After 24 h of incubation, 20 μL of supernatants from the reporter cells (HEK-Blue IFN-α/β or HEK-Blue IFN-λ) were added to 180 μL of Quanti-blue substrate (InvivoGen) and incubated at 37 °C for 1–2 h. Absorbance was measured at 650 nm using a microplate reader (PerkinElmer, EnVisionTM Multilabel Plate Reader). ..

    Article Title: CD4 T-cell platform for delivering interferons as an antiviral countermeasure with a focus on SARS-CoV-2.
    Article Snippet: .. After 24 h of incubation, 20 μL of supernatants from the reporter cells (HEK-Blue IFN-α/β or HEK-Blue IFN-λ) were added to 180 μL of Quanti-blue substrate (InvivoGen) and incubated at 37 °C for 1–2 h. Absorbance was measured at 650 nm using a microplate reader (PerkinElmer, EnVisionTM Multilabel Plate Reader). ..

    Activation Assay:

    Article Title: Lipidomic Analysis of Plasma Extracellular Vesicles from Adiponectin Deficient Mice or Metabolic Syndrome Patients Reveals Pro-Oxidative and Pro-Inflammatory Lipid Signatures Correlating with Metabolic Dysfunction.
    Article Snippet: Mitochondrial oxidative stress, particularly oxidation by superoxide, was measured by MitoSox Red (Thermo Fisher, M36008). .. RAW-dual reporter cells (InvivoGen, rawd-ismip) were seeded in 96-well plates and grown to 60%–70% confluency, then treated with EV for 4–24 h. The absorbance and luminescence, which indicates the activation of NF- κB dependent pathway and IRF3-dependent pathway, respectively, were quantified using QUANTI-Blue Solution and QUANTI-Luc 4 Lucia/Gaussia following manufacturer’s protocol. .. RNA in tissues and cells was extracted with Trizol (Invitrogen.



    Similar Products

    99
    ATCC cell lines hek293t cells atcc crl3216 h vegf reporter 293 cell line genomeditech gm c09057 experimental models
    Cell Lines Hek293t Cells Atcc Crl3216 H Vegf Reporter 293 Cell Line Genomeditech Gm C09057 Experimental Models, supplied by ATCC, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/293T/pm42285094-518-7-11
    Average 99 stars, based on 1 article reviews
    cell lines hek293t cells atcc crl3216 h vegf reporter 293 cell line genomeditech gm c09057 experimental models - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    96
    InvivoGen alkaline phosphatase seap reporter assay raw blue cells
    Alkaline Phosphatase Seap Reporter Assay Raw Blue Cells, supplied by InvivoGen, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/RAW-Blue+cells/us12655429-1771-3-21
    Average 96 stars, based on 1 article reviews
    alkaline phosphatase seap reporter assay raw blue cells - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    95
    Thermo Fisher cell reports 6
    Cell Reports 6, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/Carbonyl+cyanide+3-chlorophenylhydrazone%2C+98%25/pm42296970-201-60-56
    Average 95 stars, based on 1 article reviews
    cell reports 6 - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    97
    InvivoGen cellular cytotoxicity adcc effector function assay adcc reporter activity
    Cellular Cytotoxicity Adcc Effector Function Assay Adcc Reporter Activity, supplied by InvivoGen, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/Jurkat-Lucia+NFAT-CD16-Low+Cells/10__1080_slash_2162402x__2026__2684136-72-1-16
    Average 97 stars, based on 1 article reviews
    cellular cytotoxicity adcc effector function assay adcc reporter activity - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    86
    Fukui Bank Ltd ba f3 based tlr reporter cells
    Ba F3 Based Tlr Reporter Cells, supplied by Fukui Bank Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/ba+based+cells+f3+reporter+tlr/pm42264462-121-18-22
    Average 86 stars, based on 1 article reviews
    ba f3 based tlr reporter cells - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    95
    InvivoGen hek bluetm htlr9 reporter assay
    Hek Bluetm Htlr9 Reporter Assay, supplied by InvivoGen, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/HEK-Blue+hTLR9+cells/pm42248894-300-1-5
    Average 95 stars, based on 1 article reviews
    hek bluetm htlr9 reporter assay - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    86
    Teledyne Photometrics scmos camera cell reports 45
    Scmos Camera Cell Reports 45, supplied by Teledyne Photometrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/45+camera+cell+reports+scmos/pm42241281-276-11-21
    Average 86 stars, based on 1 article reviews
    scmos camera cell reports 45 - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Signosis Inc estrogen receptor luciferase reporter t47d stable cell line cells
    Estradiol dose-response and recovery of spiked estradiol from tampon extracts. (A) <t>T47D-luc</t> cells were treated with an 11-point estradiol dilution series starting at 30nM, followed by 10nM, 3.3nM, 1.11nM, 370pM, 123pM, 41pM, 14pM, 4.6pM, 1.5pM, and 0.5pM). For each concentration, 2 μL of steroid dilution was added to 198 μL assay medium, and cells were incubated for 24 hours. Estrogen-responsive luciferase activity was quantified using BrightGlo substrate. Luminescence values represent the mean of 4 technical replicates, and a sigmoidal dose-response curve with EC 50 determination was generated using GraphPad v10. (B) Recovery of estradiol from tampon brands A-D following spiking and extraction. One gram of each tampon from Brands A, B, C, and D were spiked with 2nM estradiol, soaked in a 1:1 water:ethanol solution for 4 hours, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted 1:100 in cell culture medium and then serially diluted 1:2 to generate 4 assay points. T47D-luc cells were incubated with a further 1:10 dilution of each tampon extract for 24 hours and luciferase activity measured using BrightGlo. Each point represents mean ± SEM of 4 technical replicates corrected for the blank control sample (1:1 ethanol:water solution SPE-extracted as per samples). The data for the spiked tampons are plotted alongside estradiol standards run in parallel.
    Estrogen Receptor Luciferase Reporter T47d Stable Cell Line Cells, supplied by Signosis Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/214+a769insasv+ba+cell+f3+line/pmc13155100-87-0-9
    Average 86 stars, based on 1 article reviews
    estrogen receptor luciferase reporter t47d stable cell line cells - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    96
    InvivoGen hek blue mtlr4 hkb mtlr4 reporter cells
    Estradiol dose-response and recovery of spiked estradiol from tampon extracts. (A) <t>T47D-luc</t> cells were treated with an 11-point estradiol dilution series starting at 30nM, followed by 10nM, 3.3nM, 1.11nM, 370pM, 123pM, 41pM, 14pM, 4.6pM, 1.5pM, and 0.5pM). For each concentration, 2 μL of steroid dilution was added to 198 μL assay medium, and cells were incubated for 24 hours. Estrogen-responsive luciferase activity was quantified using BrightGlo substrate. Luminescence values represent the mean of 4 technical replicates, and a sigmoidal dose-response curve with EC 50 determination was generated using GraphPad v10. (B) Recovery of estradiol from tampon brands A-D following spiking and extraction. One gram of each tampon from Brands A, B, C, and D were spiked with 2nM estradiol, soaked in a 1:1 water:ethanol solution for 4 hours, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted 1:100 in cell culture medium and then serially diluted 1:2 to generate 4 assay points. T47D-luc cells were incubated with a further 1:10 dilution of each tampon extract for 24 hours and luciferase activity measured using BrightGlo. Each point represents mean ± SEM of 4 technical replicates corrected for the blank control sample (1:1 ethanol:water solution SPE-extracted as per samples). The data for the spiked tampons are plotted alongside estradiol standards run in parallel.
    Hek Blue Mtlr4 Hkb Mtlr4 Reporter Cells, supplied by InvivoGen, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/HEK-Blue+mTLR4+cells/pmc13253205-177-6-14
    Average 96 stars, based on 1 article reviews
    hek blue mtlr4 hkb mtlr4 reporter cells - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    InvivoGen inducible nfb ap1 secreted alkaline phosphatase seap reporter
    Estradiol dose-response and recovery of spiked estradiol from tampon extracts. (A) <t>T47D-luc</t> cells were treated with an 11-point estradiol dilution series starting at 30nM, followed by 10nM, 3.3nM, 1.11nM, 370pM, 123pM, 41pM, 14pM, 4.6pM, 1.5pM, and 0.5pM). For each concentration, 2 μL of steroid dilution was added to 198 μL assay medium, and cells were incubated for 24 hours. Estrogen-responsive luciferase activity was quantified using BrightGlo substrate. Luminescence values represent the mean of 4 technical replicates, and a sigmoidal dose-response curve with EC 50 determination was generated using GraphPad v10. (B) Recovery of estradiol from tampon brands A-D following spiking and extraction. One gram of each tampon from Brands A, B, C, and D were spiked with 2nM estradiol, soaked in a 1:1 water:ethanol solution for 4 hours, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted 1:100 in cell culture medium and then serially diluted 1:2 to generate 4 assay points. T47D-luc cells were incubated with a further 1:10 dilution of each tampon extract for 24 hours and luciferase activity measured using BrightGlo. Each point represents mean ± SEM of 4 technical replicates corrected for the blank control sample (1:1 ethanol:water solution SPE-extracted as per samples). The data for the spiked tampons are plotted alongside estradiol standards run in parallel.
    Inducible Nfb Ap1 Secreted Alkaline Phosphatase Seap Reporter, supplied by InvivoGen, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reporter+cells/HEK-Blue+hTLR2+cells/pm42218247-271-8-18
    Average 96 stars, based on 1 article reviews
    inducible nfb ap1 secreted alkaline phosphatase seap reporter - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    Image Search Results


    Estradiol dose-response and recovery of spiked estradiol from tampon extracts. (A) T47D-luc cells were treated with an 11-point estradiol dilution series starting at 30nM, followed by 10nM, 3.3nM, 1.11nM, 370pM, 123pM, 41pM, 14pM, 4.6pM, 1.5pM, and 0.5pM). For each concentration, 2 μL of steroid dilution was added to 198 μL assay medium, and cells were incubated for 24 hours. Estrogen-responsive luciferase activity was quantified using BrightGlo substrate. Luminescence values represent the mean of 4 technical replicates, and a sigmoidal dose-response curve with EC 50 determination was generated using GraphPad v10. (B) Recovery of estradiol from tampon brands A-D following spiking and extraction. One gram of each tampon from Brands A, B, C, and D were spiked with 2nM estradiol, soaked in a 1:1 water:ethanol solution for 4 hours, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted 1:100 in cell culture medium and then serially diluted 1:2 to generate 4 assay points. T47D-luc cells were incubated with a further 1:10 dilution of each tampon extract for 24 hours and luciferase activity measured using BrightGlo. Each point represents mean ± SEM of 4 technical replicates corrected for the blank control sample (1:1 ethanol:water solution SPE-extracted as per samples). The data for the spiked tampons are plotted alongside estradiol standards run in parallel.

    Journal: Journal of the Endocrine Society

    Article Title: Estrogenic activity in tampon products

    doi: 10.1210/jendso/bvag094

    Figure Lengend Snippet: Estradiol dose-response and recovery of spiked estradiol from tampon extracts. (A) T47D-luc cells were treated with an 11-point estradiol dilution series starting at 30nM, followed by 10nM, 3.3nM, 1.11nM, 370pM, 123pM, 41pM, 14pM, 4.6pM, 1.5pM, and 0.5pM). For each concentration, 2 μL of steroid dilution was added to 198 μL assay medium, and cells were incubated for 24 hours. Estrogen-responsive luciferase activity was quantified using BrightGlo substrate. Luminescence values represent the mean of 4 technical replicates, and a sigmoidal dose-response curve with EC 50 determination was generated using GraphPad v10. (B) Recovery of estradiol from tampon brands A-D following spiking and extraction. One gram of each tampon from Brands A, B, C, and D were spiked with 2nM estradiol, soaked in a 1:1 water:ethanol solution for 4 hours, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted 1:100 in cell culture medium and then serially diluted 1:2 to generate 4 assay points. T47D-luc cells were incubated with a further 1:10 dilution of each tampon extract for 24 hours and luciferase activity measured using BrightGlo. Each point represents mean ± SEM of 4 technical replicates corrected for the blank control sample (1:1 ethanol:water solution SPE-extracted as per samples). The data for the spiked tampons are plotted alongside estradiol standards run in parallel.

    Article Snippet: Estrogen Receptor Luciferase Reporter T47D Stable Cell Line cells (Signosis, Santa Clara, CA, USA: Cat # SL-0002, T47D-luc)) were grown to 90% confluence in a 550 mL cell culture flask with RPMI 164 medium supplemented with 10% (v/v) Hyclone fetal bovine serum (GE Lifesciences) and Geneticin (75 μg mL −1 , G148, Life Technologies).

    Techniques: Concentration Assay, Incubation, Luciferase, Activity Assay, Generated, Extraction, Cell Culture, Control

    Estrogenic activity detected in extracts from 8 commercially available tampon brands (A-H). T47D-luc cells were exposed to methanolic extracts prepared from 1 g of core tampon material (string removed) from 8 tampon brands sold in New Zealand. Each 1 g sample was soaked in a 1:1 ethanol:water solution for 4 hours, sonicated, filtered, extracted, and then evaporated to dryness, and reconstituted in methanol. The final extract was diluted into assay medium at 1:1000 (1), followed by serial dilutions to generate 1:2000 (2), 1:4000 (3), and 1:8000 (4) exposure concentrations. Cells were incubated with each dilution for 24 hours, and estrogen-responsive luciferase activity was quantified using a luminescence plate reader. Data are presented as the mean ± SEM of 2 independently extracted tampons per brand, each tested as 2 portions of 1 g each, and each dilution tested with 4 technical replicates.

    Journal: Journal of the Endocrine Society

    Article Title: Estrogenic activity in tampon products

    doi: 10.1210/jendso/bvag094

    Figure Lengend Snippet: Estrogenic activity detected in extracts from 8 commercially available tampon brands (A-H). T47D-luc cells were exposed to methanolic extracts prepared from 1 g of core tampon material (string removed) from 8 tampon brands sold in New Zealand. Each 1 g sample was soaked in a 1:1 ethanol:water solution for 4 hours, sonicated, filtered, extracted, and then evaporated to dryness, and reconstituted in methanol. The final extract was diluted into assay medium at 1:1000 (1), followed by serial dilutions to generate 1:2000 (2), 1:4000 (3), and 1:8000 (4) exposure concentrations. Cells were incubated with each dilution for 24 hours, and estrogen-responsive luciferase activity was quantified using a luminescence plate reader. Data are presented as the mean ± SEM of 2 independently extracted tampons per brand, each tested as 2 portions of 1 g each, and each dilution tested with 4 technical replicates.

    Article Snippet: Estrogen Receptor Luciferase Reporter T47D Stable Cell Line cells (Signosis, Santa Clara, CA, USA: Cat # SL-0002, T47D-luc)) were grown to 90% confluence in a 550 mL cell culture flask with RPMI 164 medium supplemented with 10% (v/v) Hyclone fetal bovine serum (GE Lifesciences) and Geneticin (75 μg mL −1 , G148, Life Technologies).

    Techniques: Activity Assay, Sonication, Incubation, Luciferase, Microplate Reader Luminescence Measurement

    Independent batches of Tampon Brand D show estrogenic activity. T47D-luc cells were treated with methanolic extracts generated from 1 g of core tampon material (string removed) from 3 independent batches of Brand A and Brand D. For each batch, 3 separate tampons were extracted independently. Each 1 g sample was soaked in 1:1 ethanol:water solution for 4 hours, sonicated, filtered, extracted, and evaporated to dryness, and reconstituted in methanol. Reconstituted extracts were diluted into assay medium at 1:1000 (1), followed by serial 1:2 dilutions to produce 1:2000 (2), 1:4000 (3), and 1:8000 (4) exposure concentrations. Cells were incubated for 24 hours, and estrogen-responsive luciferase activity was quantified by using a luminescence plate reader. Data are shown as mean ± SEM of 3 independently extracted tampons per batch, tested as 2 portions of 1 g each with each dilution tested as 4 technical replicates.

    Journal: Journal of the Endocrine Society

    Article Title: Estrogenic activity in tampon products

    doi: 10.1210/jendso/bvag094

    Figure Lengend Snippet: Independent batches of Tampon Brand D show estrogenic activity. T47D-luc cells were treated with methanolic extracts generated from 1 g of core tampon material (string removed) from 3 independent batches of Brand A and Brand D. For each batch, 3 separate tampons were extracted independently. Each 1 g sample was soaked in 1:1 ethanol:water solution for 4 hours, sonicated, filtered, extracted, and evaporated to dryness, and reconstituted in methanol. Reconstituted extracts were diluted into assay medium at 1:1000 (1), followed by serial 1:2 dilutions to produce 1:2000 (2), 1:4000 (3), and 1:8000 (4) exposure concentrations. Cells were incubated for 24 hours, and estrogen-responsive luciferase activity was quantified by using a luminescence plate reader. Data are shown as mean ± SEM of 3 independently extracted tampons per batch, tested as 2 portions of 1 g each with each dilution tested as 4 technical replicates.

    Article Snippet: Estrogen Receptor Luciferase Reporter T47D Stable Cell Line cells (Signosis, Santa Clara, CA, USA: Cat # SL-0002, T47D-luc)) were grown to 90% confluence in a 550 mL cell culture flask with RPMI 164 medium supplemented with 10% (v/v) Hyclone fetal bovine serum (GE Lifesciences) and Geneticin (75 μg mL −1 , G148, Life Technologies).

    Techniques: Activity Assay, Generated, Sonication, Incubation, Luciferase, Microplate Reader Luminescence Measurement

    Estrogenic activity of internationally sourced tampon brands. T47D-luc cells were treated with methanolic extracts prepared from intact tampons (string removed) from a panel of internationally sourced tampon brands (Brands I-R). For each brand, 2 or 3 independent tampons were extracted separately on independent days. Each tampon was soaked in a 1:1 ethanol:water solution for 4 hours, sonicated, filtered, extracted, evaporated to dryness, and reconstituted in methanol. Reconstituted extracts were diluted into assay medium at 1:1000, and cells were incubated for 24 hours before estrogen-responsive luciferase activity was quantified using a luminescence plate reader. Data are shown as mean ± SEM of 2 or 3 independently extracted tampons per brand with each dilution tested as 4 technical replicates.

    Journal: Journal of the Endocrine Society

    Article Title: Estrogenic activity in tampon products

    doi: 10.1210/jendso/bvag094

    Figure Lengend Snippet: Estrogenic activity of internationally sourced tampon brands. T47D-luc cells were treated with methanolic extracts prepared from intact tampons (string removed) from a panel of internationally sourced tampon brands (Brands I-R). For each brand, 2 or 3 independent tampons were extracted separately on independent days. Each tampon was soaked in a 1:1 ethanol:water solution for 4 hours, sonicated, filtered, extracted, evaporated to dryness, and reconstituted in methanol. Reconstituted extracts were diluted into assay medium at 1:1000, and cells were incubated for 24 hours before estrogen-responsive luciferase activity was quantified using a luminescence plate reader. Data are shown as mean ± SEM of 2 or 3 independently extracted tampons per brand with each dilution tested as 4 technical replicates.

    Article Snippet: Estrogen Receptor Luciferase Reporter T47D Stable Cell Line cells (Signosis, Santa Clara, CA, USA: Cat # SL-0002, T47D-luc)) were grown to 90% confluence in a 550 mL cell culture flask with RPMI 164 medium supplemented with 10% (v/v) Hyclone fetal bovine serum (GE Lifesciences) and Geneticin (75 μg mL −1 , G148, Life Technologies).

    Techniques: Activity Assay, Sonication, Incubation, Luciferase, Microplate Reader Luminescence Measurement

    Effect of sonication on estrogenic activity of tampon extracts. T47D-luc cells were exposed to methanolic extracts prepared from 2 independent tampons per brand (Brands A and D, string removed), comparing extraction with and without sonication. Each tampon was soaked in a 1:1 ethanol:water solution for 4 hours, either sonicated or left nonsonicated, then filtered, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted into assay medium at 1:1000 (1), followed by serial 1:2 dilutions to generate 1:2000 (2) and 1:4000 (3) exposure concentrations. Cells were incubated for 24 hours, and estrogen-responsive luciferase activity was quantified. Data represent mean ± SEM of t2wo independently extracted tampons per condition with each dilution tested as 4 technical replicates.

    Journal: Journal of the Endocrine Society

    Article Title: Estrogenic activity in tampon products

    doi: 10.1210/jendso/bvag094

    Figure Lengend Snippet: Effect of sonication on estrogenic activity of tampon extracts. T47D-luc cells were exposed to methanolic extracts prepared from 2 independent tampons per brand (Brands A and D, string removed), comparing extraction with and without sonication. Each tampon was soaked in a 1:1 ethanol:water solution for 4 hours, either sonicated or left nonsonicated, then filtered, extracted, evaporated to dryness, and reconstituted in methanol. Extracts were diluted into assay medium at 1:1000 (1), followed by serial 1:2 dilutions to generate 1:2000 (2) and 1:4000 (3) exposure concentrations. Cells were incubated for 24 hours, and estrogen-responsive luciferase activity was quantified. Data represent mean ± SEM of t2wo independently extracted tampons per condition with each dilution tested as 4 technical replicates.

    Article Snippet: Estrogen Receptor Luciferase Reporter T47D Stable Cell Line cells (Signosis, Santa Clara, CA, USA: Cat # SL-0002, T47D-luc)) were grown to 90% confluence in a 550 mL cell culture flask with RPMI 164 medium supplemented with 10% (v/v) Hyclone fetal bovine serum (GE Lifesciences) and Geneticin (75 μg mL −1 , G148, Life Technologies).

    Techniques: Sonication, Activity Assay, Extraction, Incubation, Luciferase