Review



high-density multielectrode array hd-mea accura  (3Brain GmbH)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    3Brain GmbH high-density multielectrode array hd-mea accura
    High Density Multielectrode Array Hd Mea Accura, supplied by 3Brain GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/brainwave+software/pmc11864161__mmc1-25-10-15
    Average 90 stars, based on 1 article reviews
    high-density multielectrode array hd-mea accura - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Microelectrode Array:

    Article Title: How Does the Inner Retinal Network Shape the Ganglion Cells Receptive Field? A Computational Study.
    Article Snippet: Recordings were performed on the BioCamX platform with high-density-multielectrode array (HD-MEA) arena chips (3Brain GmbH, Lanquart, Switzerland), integrating 4096 square microelectrodes in a 2.67 × 2.67 mm2 area and aligned in a square grid with 42 μ spacing.

    Article Title: Electrical signaling in fungi: past and present challenges
    Article Snippet: We attempted this by using a high-density multielectrode array (MEA) from 3Brain ( 3Brain.com , Switzerland) developed to record electrical activity of neuronal networks in vitro .

    Article Title: Glial Bmal1 role in mammalian retina daily changes.
    Article Snippet: We used a 4096 electrodes CMOS high-density multielectrode array (CMOS HD-MEA, 3Brain AG, Wädenswil, Switzerland) to record light-evoked activity in response to full-field flash stimuli presented to Ctrl and Bmal1cKO mice retinae under different Michelson contrast conditions (CT25, 50, 75 and 100, see Material and Methods) and in both mesopic and photopic light regimes.

    Article Title: Combined small-molecule treatment accelerates maturation of human pluripotent stem cell-derived neurons.
    Article Snippet: The hPSC-derived SMNs were seeded on to poly(l-lysine)-coated, complementary, metal oxide semiconductor, multielectrode array (CMOS-MEA) probes (3Brain)74.

    Article Title: Dual inhibition of MAPK/ERK and BMP signaling induces entorhinal-like identity in mouse ESC-derived pallial progenitors
    Article Snippet: Cells were seeded on PLO/msLam-treated glass (200000 cells/cm2) or sterilized high-density multielectrode array (HD-MEA Accura, 3Brain) (60000 cells/chip) and allowed to adhere O/N.

    Article Title: Alteration of Neural Network and Hippocampal Slice Activation through Exosomes Derived from 5XFAD Nasal Lavage Fluid.
    Article Snippet: High-density multielectrode array (HD MEA) recording with 4096 electrodes in a CMOS Biochip (BiocamX, 3Brain GmbH, Pfäffikon, Switzerland) was conducted at a sampling rate of 9 KHz.

    Article Title: Pivotal roles of melanopsin containing retinal ganglion cells in pupillary light reflex in photopic conditions
    Article Snippet: Each retinal quadrant was placed onto an Accura HD-MEA chip (4,096 recording electrodes arranged in a 3.8 mm × 3.8 mm area multielectrode array) for the BioCAM DupleX system (3Brain, Switzerland) with a piece of clear filter paper, immobilized by a square platinum anchor.

    Article Title: Low glycemic index diet restrains epileptogenesis in a gender-specific fashion
    Article Snippet: To record electrophysiological activity in brain slices, we used the Biocam X high-density CMOS-based multielectrode arrays (HD-MEA; 3Brain AG, Switzerland).

    Activity Assay:

    Article Title: How Does the Inner Retinal Network Shape the Ganglion Cells Receptive Field? A Computational Study.
    Article Snippet: Recordings were performed on the BioCamX platform with high-density-multielectrode array (HD-MEA) arena chips (3Brain GmbH, Lanquart, Switzerland), integrating 4096 square microelectrodes in a 2.67 × 2.67 mm2 area and aligned in a square grid with 42 μ spacing.

    Article Title: Electrical signaling in fungi: past and present challenges
    Article Snippet: We attempted this by using a high-density multielectrode array (MEA) from 3Brain ( 3Brain.com , Switzerland) developed to record electrical activity of neuronal networks in vitro .

    Article Title: Glial Bmal1 role in mammalian retina daily changes.
    Article Snippet: We used a 4096 electrodes CMOS high-density multielectrode array (CMOS HD-MEA, 3Brain AG, Wädenswil, Switzerland) to record light-evoked activity in response to full-field flash stimuli presented to Ctrl and Bmal1cKO mice retinae under different Michelson contrast conditions (CT25, 50, 75 and 100, see Material and Methods) and in both mesopic and photopic light regimes.

    Article Title: Combined small-molecule treatment accelerates maturation of human pluripotent stem cell-derived neurons.
    Article Snippet: The hPSC-derived SMNs were seeded on to poly(l-lysine)-coated, complementary, metal oxide semiconductor, multielectrode array (CMOS-MEA) probes (3Brain)74.

    Article Title: Dual inhibition of MAPK/ERK and BMP signaling induces entorhinal-like identity in mouse ESC-derived pallial progenitors
    Article Snippet: Cells were seeded on PLO/msLam-treated glass (200000 cells/cm2) or sterilized high-density multielectrode array (HD-MEA Accura, 3Brain) (60000 cells/chip) and allowed to adhere O/N.

    Article Title: Alteration of Neural Network and Hippocampal Slice Activation through Exosomes Derived from 5XFAD Nasal Lavage Fluid.
    Article Snippet: High-density multielectrode array (HD MEA) recording with 4096 electrodes in a CMOS Biochip (BiocamX, 3Brain GmbH, Pfäffikon, Switzerland) was conducted at a sampling rate of 9 KHz.

    Article Title: Pivotal roles of melanopsin containing retinal ganglion cells in pupillary light reflex in photopic conditions
    Article Snippet: Each retinal quadrant was placed onto an Accura HD-MEA chip (4,096 recording electrodes arranged in a 3.8 mm × 3.8 mm area multielectrode array) for the BioCAM DupleX system (3Brain, Switzerland) with a piece of clear filter paper, immobilized by a square platinum anchor.

    Article Title: Low glycemic index diet restrains epileptogenesis in a gender-specific fashion
    Article Snippet: To record electrophysiological activity in brain slices, we used the Biocam X high-density CMOS-based multielectrode arrays (HD-MEA; 3Brain AG, Switzerland).

    In Vitro:

    Article Title: How Does the Inner Retinal Network Shape the Ganglion Cells Receptive Field? A Computational Study.
    Article Snippet: Recordings were performed on the BioCamX platform with high-density-multielectrode array (HD-MEA) arena chips (3Brain GmbH, Lanquart, Switzerland), integrating 4096 square microelectrodes in a 2.67 × 2.67 mm2 area and aligned in a square grid with 42 μ spacing.

    Article Title: Electrical signaling in fungi: past and present challenges
    Article Snippet: We attempted this by using a high-density multielectrode array (MEA) from 3Brain ( 3Brain.com , Switzerland) developed to record electrical activity of neuronal networks in vitro .

    Article Title: Glial Bmal1 role in mammalian retina daily changes.
    Article Snippet: We used a 4096 electrodes CMOS high-density multielectrode array (CMOS HD-MEA, 3Brain AG, Wädenswil, Switzerland) to record light-evoked activity in response to full-field flash stimuli presented to Ctrl and Bmal1cKO mice retinae under different Michelson contrast conditions (CT25, 50, 75 and 100, see Material and Methods) and in both mesopic and photopic light regimes.

    Article Title: Combined small-molecule treatment accelerates maturation of human pluripotent stem cell-derived neurons.
    Article Snippet: The hPSC-derived SMNs were seeded on to poly(l-lysine)-coated, complementary, metal oxide semiconductor, multielectrode array (CMOS-MEA) probes (3Brain)74.

    Article Title: Dual inhibition of MAPK/ERK and BMP signaling induces entorhinal-like identity in mouse ESC-derived pallial progenitors
    Article Snippet: Cells were seeded on PLO/msLam-treated glass (200000 cells/cm2) or sterilized high-density multielectrode array (HD-MEA Accura, 3Brain) (60000 cells/chip) and allowed to adhere O/N.

    Article Title: Alteration of Neural Network and Hippocampal Slice Activation through Exosomes Derived from 5XFAD Nasal Lavage Fluid.
    Article Snippet: High-density multielectrode array (HD MEA) recording with 4096 electrodes in a CMOS Biochip (BiocamX, 3Brain GmbH, Pfäffikon, Switzerland) was conducted at a sampling rate of 9 KHz.

    Article Title: Pivotal roles of melanopsin containing retinal ganglion cells in pupillary light reflex in photopic conditions
    Article Snippet: Each retinal quadrant was placed onto an Accura HD-MEA chip (4,096 recording electrodes arranged in a 3.8 mm × 3.8 mm area multielectrode array) for the BioCAM DupleX system (3Brain, Switzerland) with a piece of clear filter paper, immobilized by a square platinum anchor.

    Article Title: Low glycemic index diet restrains epileptogenesis in a gender-specific fashion
    Article Snippet: To record electrophysiological activity in brain slices, we used the Biocam X high-density CMOS-based multielectrode arrays (HD-MEA; 3Brain AG, Switzerland).

    Sampling:

    Article Title: How Does the Inner Retinal Network Shape the Ganglion Cells Receptive Field? A Computational Study.
    Article Snippet: Recordings were performed on the BioCamX platform with high-density-multielectrode array (HD-MEA) arena chips (3Brain GmbH, Lanquart, Switzerland), integrating 4096 square microelectrodes in a 2.67 × 2.67 mm2 area and aligned in a square grid with 42 μ spacing.

    Article Title: Electrical signaling in fungi: past and present challenges
    Article Snippet: We attempted this by using a high-density multielectrode array (MEA) from 3Brain ( 3Brain.com , Switzerland) developed to record electrical activity of neuronal networks in vitro .

    Article Title: Glial Bmal1 role in mammalian retina daily changes.
    Article Snippet: We used a 4096 electrodes CMOS high-density multielectrode array (CMOS HD-MEA, 3Brain AG, Wädenswil, Switzerland) to record light-evoked activity in response to full-field flash stimuli presented to Ctrl and Bmal1cKO mice retinae under different Michelson contrast conditions (CT25, 50, 75 and 100, see Material and Methods) and in both mesopic and photopic light regimes.

    Article Title: Combined small-molecule treatment accelerates maturation of human pluripotent stem cell-derived neurons.
    Article Snippet: The hPSC-derived SMNs were seeded on to poly(l-lysine)-coated, complementary, metal oxide semiconductor, multielectrode array (CMOS-MEA) probes (3Brain)74.

    Article Title: Dual inhibition of MAPK/ERK and BMP signaling induces entorhinal-like identity in mouse ESC-derived pallial progenitors
    Article Snippet: Cells were seeded on PLO/msLam-treated glass (200000 cells/cm2) or sterilized high-density multielectrode array (HD-MEA Accura, 3Brain) (60000 cells/chip) and allowed to adhere O/N.

    Article Title: Alteration of Neural Network and Hippocampal Slice Activation through Exosomes Derived from 5XFAD Nasal Lavage Fluid.
    Article Snippet: High-density multielectrode array (HD MEA) recording with 4096 electrodes in a CMOS Biochip (BiocamX, 3Brain GmbH, Pfäffikon, Switzerland) was conducted at a sampling rate of 9 KHz.

    Article Title: Pivotal roles of melanopsin containing retinal ganglion cells in pupillary light reflex in photopic conditions
    Article Snippet: Each retinal quadrant was placed onto an Accura HD-MEA chip (4,096 recording electrodes arranged in a 3.8 mm × 3.8 mm area multielectrode array) for the BioCAM DupleX system (3Brain, Switzerland) with a piece of clear filter paper, immobilized by a square platinum anchor.

    Article Title: Low glycemic index diet restrains epileptogenesis in a gender-specific fashion
    Article Snippet: To record electrophysiological activity in brain slices, we used the Biocam X high-density CMOS-based multielectrode arrays (HD-MEA; 3Brain AG, Switzerland).



    Similar Products

    90
    MaxWell Biosystems multielectrode array mea
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    Multielectrode Array Mea, supplied by MaxWell Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/maxone+multielectrode+arrays+mea/pmc12066556-157-21-25
    Average 90 stars, based on 1 article reviews
    multielectrode array mea - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Axion BioSystems maestro edge multielectrode array (mea) system
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    Maestro Edge Multielectrode Array (Mea) System, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/cytoview+mea+24+well+plates/10__1093_slash_narmme_slash_ugaf005-61-15-21
    Average 90 stars, based on 1 article reviews
    maestro edge multielectrode array (mea) system - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MaxWell Biosystems high-density multielectrode arrays (hd-meas
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    High Density Multielectrode Arrays (Hd Meas, supplied by MaxWell Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/high+density+microelectrode+arrays++hdmeas+/bio_rxiv__2025__01__14__630383-151-6-11
    Average 90 stars, based on 1 article reviews
    high-density multielectrode arrays (hd-meas - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Alpha MED Scientific multielectrode arrays mea probes
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    Multielectrode Arrays Mea Probes, supplied by Alpha MED Scientific, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/multi+electrode+array++med++system/10__4103_slash_nrr__nrr___d___24___00422-72-7-22
    Average 90 stars, based on 1 article reviews
    multielectrode arrays mea probes - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    3Brain GmbH high-density multielectrode array hd-mea accura
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    High Density Multielectrode Array Hd Mea Accura, supplied by 3Brain GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/brainwave+software/pmc11864161__mmc1-25-10-15
    Average 90 stars, based on 1 article reviews
    high-density multielectrode array hd-mea accura - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    3Brain GmbH high-density multielectrode array (mea)
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    High Density Multielectrode Array (Mea), supplied by 3Brain GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/array+of+microelectrodes/pmc11995700-326-6-11
    Average 90 stars, based on 1 article reviews
    high-density multielectrode array (mea) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies contact multielectrode array mea probe
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    Contact Multielectrode Array Mea Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/pmc11870732__jci___135___173493___s011-234-7-13
    Average 97 stars, based on 1 article reviews
    contact multielectrode array mea probe - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    90
    Axion BioSystems multielectrode array (mea)
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    Multielectrode Array (Mea), supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/cytoview+mea+24+well+plates/pm39661125-59-5-17
    Average 90 stars, based on 1 article reviews
    multielectrode array (mea) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Multi Channel Systems GmbH multielectrode arrays (mea) recording system
    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the <t>multielectrode</t> array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the <t>MEA</t> recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.
    Multielectrode Arrays (Mea) Recording System, supplied by Multi Channel Systems GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multielectrode+array+mea/60+electrode+thin+mea+chips/pm39299426-142-10-15
    Average 90 stars, based on 1 article reviews
    multielectrode arrays (mea) recording system - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the multielectrode array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the MEA recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.

    Journal: Frontiers in Neuroanatomy

    Article Title: Chronic silencing of Drd1a-Cre+ neurons impairs dopaminergic-driven cortical activation

    doi: 10.3389/fnana.2025.1548545

    Figure Lengend Snippet: Schematic description of the experimental conditions for electrophysiology. (A) Timeline of the electrophysiological recordings in the multielectrode array system. Three baseline recordings with aCSF and a solution of 200 nM of 4-AP were followed by 10 min of a continuous administration of a 2 μM solution of either D1 or D2 agonist. (B) Example of the MEA recording system with a slice positioned to ensure that the areas of interest (S1 and S2) contact the recording electrodes. (C) Schematic of the labeling of electrodes using the Paxinos mouse brain atlas as a reference.

    Article Snippet: We evaluated the role of the Drd1a-Cre+ neurons in the maintenance and activation of dopaminergic networks in somatosensory cortex using a multielectrode array (MEA) (MaxOne, Maxwell Biosystems).

    Techniques: Labeling