Review




Structured Review

Philips Healthcare t philips ingenia mri scanner
T Philips Ingenia Mri Scanner, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/3+philips+scanner+t/pmc13276324-117-6-7
Average 86 stars, based on 1 article reviews
t philips ingenia mri scanner - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

Diagnostic Assay:

Article Title: Hyperintense acute reperfusion marker (HARM) and thrombus analysis in acute ischemic stroke
Article Snippet: MRI was performed using 1.5-T scanners (Ingenia, Philips Healthcare, Best, the Netherlands, or Magnetom Aera, Siemens, Munich, Germany).

Article Title: Partitioned Internal Auditory Canal: Association With Cochlear Aperture Anomalies.
Article Snippet: Objective: To investigate the association between partitioned internal auditory canal (IAC) and other inner ear abnormalities.. Methods: The temporal bone computed tomography (CT) and magnetic resonance imaging (MRI) findings of ears with partitioned IAC were retrospectively analyzed.. The IAC was considered narrow if its midportion diameter < 2 mm.

Article Title: Application of ultrasound-guided percutaneous catheter drainage in the treatment of tuberculous psoas abscesses
Article Snippet: Ultrasound (Philips iU-Elite ultrasonic diagnostic apparatus (Washington, USA) with the C5-1 broadband convex array probe (frequency 1–5 MHz)), CT (Philips Brilliance iCT (Ohio, USA)), and MRI (Philips Achieva (Ohio, USA) 3.0 T) were performed to assess the condition, and personalized management plans were developed based on the results and patient preferences.

Article Title: TSPO-PET-measurable neuroinflammation associates with brain atrophy in multiple sclerosis.
Article Snippet: At WMIC, MRI was performed with 1.5T Achieva (HC, n = 25) or 3T Achieva (HC, n = 14) scanner (Philips, Best, the Netherlands).

Article Title: Role of Whole-Body Magnetic Resonance Imaging in Detecting Metastasis in Patients With Known Cancer
Article Snippet: WB-MRI was subsequently performed using a 1.5-T Philips Achieva DS MR system (Philips Healthcare, Brazil).

Article Title: Macrophage signaling associates with fibrogenic program activation in periductal fibroblasts in pediatric primary sclerosing cholangitis.
Article Snippet: Briefly, MRI were performed at a field strength of 1.5 Tesla (Ingenia; Philips Healthcare, Best, the Netherlands).

Magnetic Resonance Imaging:

Article Title: Hyperintense acute reperfusion marker (HARM) and thrombus analysis in acute ischemic stroke
Article Snippet: MRI was performed using 1.5-T scanners (Ingenia, Philips Healthcare, Best, the Netherlands, or Magnetom Aera, Siemens, Munich, Germany).

Article Title: Partitioned Internal Auditory Canal: Association With Cochlear Aperture Anomalies.
Article Snippet: Objective: To investigate the association between partitioned internal auditory canal (IAC) and other inner ear abnormalities.. Methods: The temporal bone computed tomography (CT) and magnetic resonance imaging (MRI) findings of ears with partitioned IAC were retrospectively analyzed.. The IAC was considered narrow if its midportion diameter < 2 mm.

Article Title: Application of ultrasound-guided percutaneous catheter drainage in the treatment of tuberculous psoas abscesses
Article Snippet: Ultrasound (Philips iU-Elite ultrasonic diagnostic apparatus (Washington, USA) with the C5-1 broadband convex array probe (frequency 1–5 MHz)), CT (Philips Brilliance iCT (Ohio, USA)), and MRI (Philips Achieva (Ohio, USA) 3.0 T) were performed to assess the condition, and personalized management plans were developed based on the results and patient preferences.

Article Title: TSPO-PET-measurable neuroinflammation associates with brain atrophy in multiple sclerosis.
Article Snippet: At WMIC, MRI was performed with 1.5T Achieva (HC, n = 25) or 3T Achieva (HC, n = 14) scanner (Philips, Best, the Netherlands).

Article Title: Role of Whole-Body Magnetic Resonance Imaging in Detecting Metastasis in Patients With Known Cancer
Article Snippet: WB-MRI was subsequently performed using a 1.5-T Philips Achieva DS MR system (Philips Healthcare, Brazil).

Article Title: Macrophage signaling associates with fibrogenic program activation in periductal fibroblasts in pediatric primary sclerosing cholangitis.
Article Snippet: Briefly, MRI were performed at a field strength of 1.5 Tesla (Ingenia; Philips Healthcare, Best, the Netherlands).



Similar Products

86
Siemens Healthineers t whole body mri system
T Whole Body Mri System, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/body+mri+system+t+whole/pmc13200137-153-8-13
Average 86 stars, based on 1 article reviews
t whole body mri system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

94
Psychology Software Tools mri compatible fiber optic response unit
Mri Compatible Fiber Optic Response Unit, supplied by Psychology Software Tools, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/Celeritas/pm42805440-59-5-10
Average 94 stars, based on 1 article reviews
mri compatible fiber optic response unit - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

86
Philips Healthcare t philips ingenia mri scanner
T Philips Ingenia Mri Scanner, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/3+philips+scanner+t/pmc13276324-117-6-7
Average 86 stars, based on 1 article reviews
t philips ingenia mri scanner - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Philips Healthcare t mri scanner
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
T Mri Scanner, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/mri+scanner+t/pmc13276516-99-11-14
Average 86 stars, based on 1 article reviews
t mri scanner - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Siemens Healthineers mri scanner details
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Mri Scanner Details, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/mri+scanner+t/pmc13196352-31-0-11
Average 86 stars, based on 1 article reviews
mri scanner details - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Philips Healthcare mri images
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Mri Images, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/images+mri/pmc13264218-71-12-16
Average 86 stars, based on 1 article reviews
mri images - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

99
MyoLearn electromyography (emg) research
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Electromyography (Emg) Research, supplied by MyoLearn, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/Electromyography+(EMG)+Research/custom%40emg%4042466981
Average 99 stars, based on 1 article reviews
electromyography (emg) research - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

86
Siemens Healthineers 3 0 t magnetic resonance imaging mri
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
3 0 T Magnetic Resonance Imaging Mri, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/imaging+magnetic+resonance/pmc13266175-41-23-29
Average 86 stars, based on 1 article reviews
3 0 t magnetic resonance imaging mri - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

94
Psychology Software Tools hyperion
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Hyperion, supplied by Psychology Software Tools, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/Hyperion/custom%40pst-101891%4042342996
Average 94 stars, based on 1 article reviews
hyperion - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

86
Siemens Healthineers mri
Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic <t>MRI),</t> demonstrating patient-specific changes <t>in</t> <t>T2/FLAIR</t> region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Mri, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mri/mri/pmc08633812-25-7-8
Average 86 stars, based on 1 article reviews
mri - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

Image Search Results


Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic MRI), demonstrating patient-specific changes in T2/FLAIR region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

Journal: Clinical and Translational Radiation Oncology

Article Title: Monitoring glioblastoma dynamics during chemoradiation on the 1.5 T magnetic resonance imaging-linear accelerator

doi: 10.1016/j.ctro.2026.101200

Figure Lengend Snippet: Representative axial (A-C) and sagittal (C) FLAIR images from three patients at fraction 0 (F0), fraction 15 (F15), fraction 30 (F30), and 1 month post-radiotherapy (PM1; diagnostic MRI), demonstrating patient-specific changes in T2/FLAIR region-of-interest (ROI) volume (V), percentage change in V relative to F0 (V rel ), and migration distance (d migrate ). The baseline ROI at F0 is outlined in pink; ROIs at F15, F30, and PM1 are outlined in dark blue. (A) Unmethylated tumor following gross total resection (GTR), without early progression, showing decreasing ROI volume with low d migrate across timepoints. (B) Unmethylated tumor following subtotal resection (STR), with early progression, showing increasing ROI volume with increasing d migrate across timepoints. (C) Methylated tumor following STR, without early progression, showing decreasing ROI volume with large d migrate across timepoints. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

Article Snippet: For radiotherapy planning, all patients underwent MR simulation on a 1.5 T MRI scanner (Philips Ingenia) with gadolinium-enhanced T1-weighted, T2-weighted, diffusion-weight imaging (DWI), and fluid-attenuated inversion recovery (FLAIR) volumetric sequences.

Techniques: Diagnostic Assay, Migration, Methylation

Longitudinal relative change in MR-Linac T2/FLAIR region of interest (ROI) volume from baseline (V rel , %) during radiotherapy by (a) fractionation regimen, (b) early progression status (progression ≤ 6 months after radiotherapy), (c) methylation status, and (d) combined early progression and methylation status. Dotted lines represent individual patients; solid lines indicate group medians. PM1 denotes the post-treatment MRI performed one month after radiotherapy and is shown separately for the 15-fraction and 30-fraction cohorts; patients treated with 15 fractions do not contribute data beyond F15.

Journal: Clinical and Translational Radiation Oncology

Article Title: Monitoring glioblastoma dynamics during chemoradiation on the 1.5 T magnetic resonance imaging-linear accelerator

doi: 10.1016/j.ctro.2026.101200

Figure Lengend Snippet: Longitudinal relative change in MR-Linac T2/FLAIR region of interest (ROI) volume from baseline (V rel , %) during radiotherapy by (a) fractionation regimen, (b) early progression status (progression ≤ 6 months after radiotherapy), (c) methylation status, and (d) combined early progression and methylation status. Dotted lines represent individual patients; solid lines indicate group medians. PM1 denotes the post-treatment MRI performed one month after radiotherapy and is shown separately for the 15-fraction and 30-fraction cohorts; patients treated with 15 fractions do not contribute data beyond F15.

Article Snippet: For radiotherapy planning, all patients underwent MR simulation on a 1.5 T MRI scanner (Philips Ingenia) with gadolinium-enhanced T1-weighted, T2-weighted, diffusion-weight imaging (DWI), and fluid-attenuated inversion recovery (FLAIR) volumetric sequences.

Techniques: Fractionation, Methylation

Longitudinal migration distance (d migrate , mm) of MR-Linac T2/FLAIR region of interest (ROI) during radiotherapy by (a) fractionation regimen, (b) early progression status (progression ≤ 6 months after radiotherapy), (c) methylation status, and (d) combined early progression and methylation status. Dotted lines show individual patients; solid lines indicate group medians. PM1 denotes the post-treatment MRI performed one month after radiotherapy and is shown separately for the 15-fraction and 30-fraction cohorts; patients treated with 15 fractions do not contribute data beyond F15.

Journal: Clinical and Translational Radiation Oncology

Article Title: Monitoring glioblastoma dynamics during chemoradiation on the 1.5 T magnetic resonance imaging-linear accelerator

doi: 10.1016/j.ctro.2026.101200

Figure Lengend Snippet: Longitudinal migration distance (d migrate , mm) of MR-Linac T2/FLAIR region of interest (ROI) during radiotherapy by (a) fractionation regimen, (b) early progression status (progression ≤ 6 months after radiotherapy), (c) methylation status, and (d) combined early progression and methylation status. Dotted lines show individual patients; solid lines indicate group medians. PM1 denotes the post-treatment MRI performed one month after radiotherapy and is shown separately for the 15-fraction and 30-fraction cohorts; patients treated with 15 fractions do not contribute data beyond F15.

Article Snippet: For radiotherapy planning, all patients underwent MR simulation on a 1.5 T MRI scanner (Philips Ingenia) with gadolinium-enhanced T1-weighted, T2-weighted, diffusion-weight imaging (DWI), and fluid-attenuated inversion recovery (FLAIR) volumetric sequences.

Techniques: Migration, Fractionation, Methylation