Review



fluorescence plate reader  (Tecan Systems)


Bioz Verified Symbol Tecan Systems is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    Tecan Systems fluorescence plate reader
    Fluorescence Plate Reader, supplied by Tecan Systems, used in various techniques. Bioz Stars score: 96/100, based on 3240 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/Infinite+200+Pro+M+Plex%2C+Multi-mode+microplate+reader%2C+Monochromator+optics/pm42855589-525-11-17
    Average 96 stars, based on 3240 article reviews
    fluorescence plate reader - by Bioz Stars, 2026-10
    96/100 stars

    Images

    Related Articles

    Concentration Assay:

    Article Title: Rosmarinic acid derivative, Rosmarinic acid-derived particles, composition containing same for treating inflammatory disease
    Article Snippet: The amount of ICG in RANPs was quantified by first treating ICG-encapsulated RANPs with 0.5% Triton-X and then measuring the ICG concentration using a fluorescence microplate reader (Spark multimode microplate reader; Tecan, Switzerlans).

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity.
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland). https://doi.org/10.3390/antiox15010138

    Article Title: Nanoplastics induce SH-SY5Y cell damage through oxidative stress and disruption of amino acid metabolism.
    Article Snippet: With the pervasive environmental distribution of plastics, their fragmentation into nanoplastics (NPs) has raised growing concerns regarding potential biological toxicity, particularly in neuronal cells.. This study investigated the toxic effects and underlying mechanisms of NPs on SH-SY5Y cells.. Five types of NPs were first systematically characterized using scanning electron microscopy (SEM), hydrodynamic diameter measurement, and Zeta potential analysis.

    Article Title: rIL-22 Alleviates Severe Acute Pancreatitis and Secondary Multiple Organ Injury Induced by Caerulein in Mice
    Article Snippet: Plasma was diluted in an equal volume of PBS and measured for FITC–dextran concentration with a fluorescence microplate reader (Tecan Spark) at an excitation wavelength of 485 nm and emission wavelength of 530 nm.

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland).

    Article Title: Dual-targeted milk exosome-coated probiotics for IBD therapy via ROS scavenging and microbiota modulation
    Article Snippet: Fluorescence was measured using a fluorescence microplate reader (TECAN Spark 10M, China) under 530 nm emission and 485 nm excitation.

    Article Title: Artificial human stem cell niche created in cartilage-inspired hydrogel for enhanced articular cartilage regeneration.
    Article Snippet: Stem cell-based therapies and liposome-integrated hydrogel matrix strategies are promising for articular cartilage regeneration.. However, challenges persist due to the loss of stemness during in vitro expansion and the lack of control over stem cell behavior in vivo.. Herein, we design a cartilage-inspired hydrogel scaffold similar to the native stem cell niche and expect to enhance chondrogenesis for cartilage repair.

    Article Title: Bioengineered hybrid spheroids integrating mesenchymal stem cells and metformin-loaded microspheres for the treatment of sepsis-induced liver injury.
    Article Snippet: Sepsis is a complex and heterogeneous inflammatory and immune response, causing multi-organ dysfunction and accounting for approximately 20% of all global deaths.. Currently, antibiotics and organsupportive therapy are the major available supportive treatments for sepsis, which may be due to multiple pathways of disease progression that make them highly evasive.. Besides, Food and Drug Administrationapproved drugs, cells, or biologics for sepsis treatment are unavailable, and preclinical data do not seem to reduce mortality in clinical trials, indicating the need for an alternative therapeutic approach.

    Liposomes:

    Article Title: Rosmarinic acid derivative, Rosmarinic acid-derived particles, composition containing same for treating inflammatory disease
    Article Snippet: The amount of ICG in RANPs was quantified by first treating ICG-encapsulated RANPs with 0.5% Triton-X and then measuring the ICG concentration using a fluorescence microplate reader (Spark multimode microplate reader; Tecan, Switzerlans).

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity.
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland). https://doi.org/10.3390/antiox15010138

    Article Title: Nanoplastics induce SH-SY5Y cell damage through oxidative stress and disruption of amino acid metabolism.
    Article Snippet: With the pervasive environmental distribution of plastics, their fragmentation into nanoplastics (NPs) has raised growing concerns regarding potential biological toxicity, particularly in neuronal cells.. This study investigated the toxic effects and underlying mechanisms of NPs on SH-SY5Y cells.. Five types of NPs were first systematically characterized using scanning electron microscopy (SEM), hydrodynamic diameter measurement, and Zeta potential analysis.

    Article Title: rIL-22 Alleviates Severe Acute Pancreatitis and Secondary Multiple Organ Injury Induced by Caerulein in Mice
    Article Snippet: Plasma was diluted in an equal volume of PBS and measured for FITC–dextran concentration with a fluorescence microplate reader (Tecan Spark) at an excitation wavelength of 485 nm and emission wavelength of 530 nm.

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland).

    Article Title: Dual-targeted milk exosome-coated probiotics for IBD therapy via ROS scavenging and microbiota modulation
    Article Snippet: Fluorescence was measured using a fluorescence microplate reader (TECAN Spark 10M, China) under 530 nm emission and 485 nm excitation.

    Article Title: Artificial human stem cell niche created in cartilage-inspired hydrogel for enhanced articular cartilage regeneration.
    Article Snippet: Stem cell-based therapies and liposome-integrated hydrogel matrix strategies are promising for articular cartilage regeneration.. However, challenges persist due to the loss of stemness during in vitro expansion and the lack of control over stem cell behavior in vivo.. Herein, we design a cartilage-inspired hydrogel scaffold similar to the native stem cell niche and expect to enhance chondrogenesis for cartilage repair.

    Article Title: Bioengineered hybrid spheroids integrating mesenchymal stem cells and metformin-loaded microspheres for the treatment of sepsis-induced liver injury.
    Article Snippet: Sepsis is a complex and heterogeneous inflammatory and immune response, causing multi-organ dysfunction and accounting for approximately 20% of all global deaths.. Currently, antibiotics and organsupportive therapy are the major available supportive treatments for sepsis, which may be due to multiple pathways of disease progression that make them highly evasive.. Besides, Food and Drug Administrationapproved drugs, cells, or biologics for sepsis treatment are unavailable, and preclinical data do not seem to reduce mortality in clinical trials, indicating the need for an alternative therapeutic approach.

    Fluorescence:

    Article Title: Rosmarinic acid derivative, Rosmarinic acid-derived particles, composition containing same for treating inflammatory disease
    Article Snippet: The amount of ICG in RANPs was quantified by first treating ICG-encapsulated RANPs with 0.5% Triton-X and then measuring the ICG concentration using a fluorescence microplate reader (Spark multimode microplate reader; Tecan, Switzerlans).

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity.
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland). https://doi.org/10.3390/antiox15010138

    Article Title: Nanoplastics induce SH-SY5Y cell damage through oxidative stress and disruption of amino acid metabolism.
    Article Snippet: With the pervasive environmental distribution of plastics, their fragmentation into nanoplastics (NPs) has raised growing concerns regarding potential biological toxicity, particularly in neuronal cells.. This study investigated the toxic effects and underlying mechanisms of NPs on SH-SY5Y cells.. Five types of NPs were first systematically characterized using scanning electron microscopy (SEM), hydrodynamic diameter measurement, and Zeta potential analysis.

    Article Title: rIL-22 Alleviates Severe Acute Pancreatitis and Secondary Multiple Organ Injury Induced by Caerulein in Mice
    Article Snippet: Plasma was diluted in an equal volume of PBS and measured for FITC–dextran concentration with a fluorescence microplate reader (Tecan Spark) at an excitation wavelength of 485 nm and emission wavelength of 530 nm.

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland).

    Article Title: Dual-targeted milk exosome-coated probiotics for IBD therapy via ROS scavenging and microbiota modulation
    Article Snippet: Fluorescence was measured using a fluorescence microplate reader (TECAN Spark 10M, China) under 530 nm emission and 485 nm excitation.

    Article Title: Artificial human stem cell niche created in cartilage-inspired hydrogel for enhanced articular cartilage regeneration.
    Article Snippet: Stem cell-based therapies and liposome-integrated hydrogel matrix strategies are promising for articular cartilage regeneration.. However, challenges persist due to the loss of stemness during in vitro expansion and the lack of control over stem cell behavior in vivo.. Herein, we design a cartilage-inspired hydrogel scaffold similar to the native stem cell niche and expect to enhance chondrogenesis for cartilage repair.

    Article Title: Bioengineered hybrid spheroids integrating mesenchymal stem cells and metformin-loaded microspheres for the treatment of sepsis-induced liver injury.
    Article Snippet: Sepsis is a complex and heterogeneous inflammatory and immune response, causing multi-organ dysfunction and accounting for approximately 20% of all global deaths.. Currently, antibiotics and organsupportive therapy are the major available supportive treatments for sepsis, which may be due to multiple pathways of disease progression that make them highly evasive.. Besides, Food and Drug Administrationapproved drugs, cells, or biologics for sepsis treatment are unavailable, and preclinical data do not seem to reduce mortality in clinical trials, indicating the need for an alternative therapeutic approach.

    Clinical Proteomics:

    Article Title: Rosmarinic acid derivative, Rosmarinic acid-derived particles, composition containing same for treating inflammatory disease
    Article Snippet: The amount of ICG in RANPs was quantified by first treating ICG-encapsulated RANPs with 0.5% Triton-X and then measuring the ICG concentration using a fluorescence microplate reader (Spark multimode microplate reader; Tecan, Switzerlans).

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity.
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland). https://doi.org/10.3390/antiox15010138

    Article Title: Nanoplastics induce SH-SY5Y cell damage through oxidative stress and disruption of amino acid metabolism.
    Article Snippet: With the pervasive environmental distribution of plastics, their fragmentation into nanoplastics (NPs) has raised growing concerns regarding potential biological toxicity, particularly in neuronal cells.. This study investigated the toxic effects and underlying mechanisms of NPs on SH-SY5Y cells.. Five types of NPs were first systematically characterized using scanning electron microscopy (SEM), hydrodynamic diameter measurement, and Zeta potential analysis.

    Article Title: rIL-22 Alleviates Severe Acute Pancreatitis and Secondary Multiple Organ Injury Induced by Caerulein in Mice
    Article Snippet: Plasma was diluted in an equal volume of PBS and measured for FITC–dextran concentration with a fluorescence microplate reader (Tecan Spark) at an excitation wavelength of 485 nm and emission wavelength of 530 nm.

    Article Title: Differential Toxicity of Water-Soluble Versus Water-Insoluble Components of Cowshed PM2.5 on Ovarian Granulosa Cells and the Regulatory Role of Txnip in Overall Toxicity
    Article Snippet: Fluorescence intensity was measured using a fluorescence microplate reader (Spark, Tecan Group Ltd., Zurich, Switzerland).

    Article Title: Dual-targeted milk exosome-coated probiotics for IBD therapy via ROS scavenging and microbiota modulation
    Article Snippet: Fluorescence was measured using a fluorescence microplate reader (TECAN Spark 10M, China) under 530 nm emission and 485 nm excitation.

    Article Title: Artificial human stem cell niche created in cartilage-inspired hydrogel for enhanced articular cartilage regeneration.
    Article Snippet: Stem cell-based therapies and liposome-integrated hydrogel matrix strategies are promising for articular cartilage regeneration.. However, challenges persist due to the loss of stemness during in vitro expansion and the lack of control over stem cell behavior in vivo.. Herein, we design a cartilage-inspired hydrogel scaffold similar to the native stem cell niche and expect to enhance chondrogenesis for cartilage repair.

    Article Title: Bioengineered hybrid spheroids integrating mesenchymal stem cells and metformin-loaded microspheres for the treatment of sepsis-induced liver injury.
    Article Snippet: Sepsis is a complex and heterogeneous inflammatory and immune response, causing multi-organ dysfunction and accounting for approximately 20% of all global deaths.. Currently, antibiotics and organsupportive therapy are the major available supportive treatments for sepsis, which may be due to multiple pathways of disease progression that make them highly evasive.. Besides, Food and Drug Administrationapproved drugs, cells, or biologics for sepsis treatment are unavailable, and preclinical data do not seem to reduce mortality in clinical trials, indicating the need for an alternative therapeutic approach.



    Similar Products

    96
    Tecan Systems fluorescence plate reader
    Fluorescence Plate Reader, supplied by Tecan Systems, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/Infinite+200+Pro+M+Plex%2C+Multi-mode+microplate+reader%2C+Monochromator+optics/pm42855589-525-11-17
    Average 96 stars, based on 1 article reviews
    fluorescence plate reader - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc basolateral fluorescence
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Basolateral Fluorescence, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/SpectraMax+iD3-ID5/pmc13643098-531-10-16
    Average 96 stars, based on 1 article reviews
    basolateral fluorescence - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    97
    Danaher Inc spectramax m5 fluorescent spectrophotometric plate reader
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Spectramax M5 Fluorescent Spectrophotometric Plate Reader, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/SpectraMax+M5+Series+Microplate+Readers/10__1038_slash_s41467___026___78140___5-326-2-2
    Average 97 stars, based on 1 article reviews
    spectramax m5 fluorescent spectrophotometric plate reader - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    99
    BMG Labtech fluostar omega fluorescence 566 microplate reader 167
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Fluostar Omega Fluorescence 566 Microplate Reader 167, supplied by BMG Labtech, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/FLUOstar+Omega/10__1158_slash_2767___9764__crc___26___0150-83-5-12
    Average 99 stars, based on 1 article reviews
    fluostar omega fluorescence 566 microplate reader 167 - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    98
    Danaher Inc fluorescence intensity
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Fluorescence Intensity, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/FlexStation+3/10__1016_slash_j__apsb__2026__09__024-120-7-23
    Average 98 stars, based on 1 article reviews
    fluorescence intensity - by Bioz Stars, 2026-10
    98/100 stars
      Buy from Supplier

    99
    BMG Labtech fluorescence microplate reader
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Fluorescence Microplate Reader, supplied by BMG Labtech, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/FLUOstar+Omega/10__1038_slash_s41598___026___63336___y-123-13-18
    Average 99 stars, based on 1 article reviews
    fluorescence microplate reader - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    BMG Labtech clariostar fluorescent microplate reader
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Clariostar Fluorescent Microplate Reader, supplied by BMG Labtech, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/CLARIOstar+Plus/10__1016_slash_j__mtadv__2026__100827-348-34-38
    Average 99 stars, based on 1 article reviews
    clariostar fluorescent microplate reader - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    86
    Hangzhou Allsheng Instruments fluorescent microplate reader
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Fluorescent Microplate Reader, supplied by Hangzhou Allsheng Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/microplate+reader/pm42142422-179-13-21
    Average 86 stars, based on 1 article reviews
    fluorescent microplate reader - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    99
    BMG Labtech fluostar omega fluorescence 556 microplate reader
    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative <t>apical‐to‐basolateral</t> transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.
    Fluostar Omega Fluorescence 556 Microplate Reader, supplied by BMG Labtech, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fluorescence+microplate+reader/FLUOstar+Omega/us12595312-723-5-11
    Average 99 stars, based on 1 article reviews
    fluostar omega fluorescence 556 microplate reader - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    Image Search Results


    Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative apical‐to‐basolateral transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.

    Journal: Advanced Science

    Article Title: 3D Bioprinted Blood–Brain–Tumor Barrier Spheroid‐Based In Situ Evaluation of Anticancer Compounds Against Glioblastoma: ROS‐Producing Ruthenium as a Potential Therapeutic Candidate

    doi: 10.1002/advs.78150

    Figure Lengend Snippet: Cytotoxicity profiling and Transwell permeability assessment of test compounds across hCMEC/D3 and U‐87 MG cell models. (A1–A4) Cell viability of hCMEC/D3 human cerebral microvascular endothelial cells following 24 h treatment with Rh123 (A1), Ru (A2), Osi (A3), or TMZ (A4), assessed by CellTiter‐Glo luminescent cell viability assay. (B1–B3) Cell viability of U‐87 MG glioblastoma cells following 48 h treatment with Ru (B1), Osi (B2), or TMZ (B3), assessed by MTT assay. (C1–C4) Cumulative apical‐to‐basolateral transport profiles of Rh123 (C1), Ru (C2), Osi (C3), and TMZ (C4) across hCMEC/D3 monolayers in the presence (Ver+) or absence (Ver−) of the P‐glycoprotein inhibitor verapamil (Ver, 100 µM), measured at 15‐min intervals over 60 min. (D1–D4) Apparent permeability coefficients (P app ) of Rh123 (D1), Ru (D2), Osi (D3), and TMZ (D4) in the presence (Ver+) or absence (Ver−) of verapamil. ** p < 0.01, *** p < 0.001, **** p < 0.0001; n.s., not significant. Rh123, Rhodamine‐123; Ru, ruthenium compound; Osi, osimertinib; TMZ, temozolomide; Ver, verapamil. Data in (A1–A4) and (B1–B3) are presented as mean ± SD of n = 3 replicate wells per concentration seeded in parallel; data in (C1–C4) and (D1–D4) are presented as mean ± SD of n = 3 Transwell inserts seeded in parallel per condition. Statistical significance was assessed by ordinary one‐way ANOVA followed by Tukey's multiple‐comparisons test, using a two‐sided alpha of 0.05. Analyses were performed using GraphPad Prism 11.0.2.

    Article Snippet: Following a 60‐min incubation at 37°C with agitation (100 rpm), basolateral fluorescence (Ex/Em 485/530 nm, iD3, Molecular Devices) was measured and compared with blank inserts to confirm barrier integrity.

    Techniques: Profiling, Permeability, Cell Viability Assay, MTT Assay, Ruthenium, Concentration Assay