Review




Structured Review

Biacore carboxymethyl dextran cm 5 sensor chip
Carboxymethyl Dextran Cm 5 Sensor Chip, supplied by Biacore, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/biosensor+chips+dextran/pmc13039201-132-17-29
Average 86 stars, based on 1 article reviews
carboxymethyl dextran cm 5 sensor chip - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

Control:

Article Title: AlbuCORE: an albumin-based molecular scaffold for multivalent biologics design
Article Snippet: Assays were performed by indirectly capturing the AlbuCORE and Azymetric constructs using 2000 RU surfaces of anti-HSA goat polyclonal antibody (Abcam cat#ab18074) or goat anti-Fc polyclonal (Jackson ImmunoResearch cat#109-001-008) and flowing HER2 over top. .. The antibody capture surfaces were created using standard amine coupling to a CM-5 sensor chip using the Immobilization Wizard application within the Biacore T200 control software. ..

Software:

Article Title: AlbuCORE: an albumin-based molecular scaffold for multivalent biologics design
Article Snippet: Assays were performed by indirectly capturing the AlbuCORE and Azymetric constructs using 2000 RU surfaces of anti-HSA goat polyclonal antibody (Abcam cat#ab18074) or goat anti-Fc polyclonal (Jackson ImmunoResearch cat#109-001-008) and flowing HER2 over top. .. The antibody capture surfaces were created using standard amine coupling to a CM-5 sensor chip using the Immobilization Wizard application within the Biacore T200 control software. ..

SPR Assay:

Article Title: CD38 modulating antibody
Article Snippet: Kinetics data were fit using a 1:1 binding model in the data analysis software provided by ForteBio. .. Alternatively the affinity for the anti human CD38 antibodies was determined by measuring their KD by SPR in a Biacore 2000 using a CM-5 Sensor chip with an ambient experiment temperature of 25° C. Anti-human antibody was initially immobilised across all flow cells in analysis buffer (pH 7.4, 10 mM HEPES, 150 mM NaCl, 3 mM EDTA, 0.05% Tween 20) to an RU of between 12,000-14,000 over 10 minutes. ..

Article Title: Development of a novel fully-human anti-CD123 antibody to target acute myeloid leukemia.
Article Snippet: Monoclonal antibodies are being considered as biopharmaceuticals for the in vivo targeting of acute myeloid leukemia.. Here we describe the generation and characterization of a fullyhuman monoclonal antibody specific to CD123, a surface marker which is overexpressed in a variety of hematological disorders, including acute myeloid leukemia.. The cloning and expression of the extracellular portion of CD123 as recombinant Fc fusion allowed the selection and affinity maturation of a human antibody, called H9, which specifically recognized the cognate antigen in biochemical assays and on leukemic cells.

Article Title: CD38 antibody
Article Snippet: .. Alternatively, the affinity for the anti-human CD38 antibodies was determined by measuring their KD by SPR in a Biacore 2000 using a CM-5 Sensor chip with an ambient experiment temperature of 25° C. Anti-human antibody was initially immobilised across all flow cells in analysis buffer (pH 7.4, 10 mM HEPES, 150 mM NaCl, 3 mM EDTA, 0.05% Tween 20) to an RU of between 12,000-14,000 over 10 minutes. ..

Functional Assay:

Article Title: Association of amphipathic lignin derivatives with cellobiohydrolase groups improves enzymatic saccharification of lignocellulosics
Article Snippet: Amphipathic lignin derivatives (ALDs), prepared from hardwood acetic acid lignin and softwood soda lignin via coupling with a monoepoxylated polyethylene glycol, have been reported to improve the enzymatic saccharification efficiency of lignocellulose while maintaining significant residual cellulase activity after saccharification.. We previously demonstrated that the effect of ALDs was caused by a direct interaction between ALDs and Cel6A (or CBH II).. In this study, a different ALD was prepared from softwood kraft lignin in addition to aforementioned ALDs.

other:

Article Title: Interactions between Plasmodium falciparum skeleton-binding protein 1 and the membrane skeleton of malaria-infected red blood cells
Article Snippet: Quantification of protein–protein interactions by surface plasmon resonance A well-established surface plasmon resonance-based technique was used to quantify protein–protein interactions using a BIAcore 3000 (BIAcore, Piscataway, NJ, USA).



Similar Products

86
Biacore carboxymethyl dextran cm 5 sensor chip
Carboxymethyl Dextran Cm 5 Sensor Chip, supplied by Biacore, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/biosensor+chips+dextran/pmc13039201-132-17-29
Average 86 stars, based on 1 article reviews
carboxymethyl dextran cm 5 sensor chip - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Cytiva Europe sensor chip cm-5
Sensor Chip Cm 5, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/cm5+sensor+chip/pm40344836-58-9-13
Average 90 stars, based on 1 article reviews
sensor chip cm-5 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biacore cm-5 sensor chip
Cm 5 Sensor Chip, supplied by Biacore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/cm5+sensor+chip/pm40223692-273-9-13
Average 90 stars, based on 1 article reviews
cm-5 sensor chip - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biacore cm-5 sensor chips
Cm 5 Sensor Chips, supplied by Biacore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/cm5+sensor+chip/pm38250832-40-16-22
Average 90 stars, based on 1 article reviews
cm-5 sensor chips - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biacore streptavidin-coupled cm-5 sensor chips
Streptavidin Coupled Cm 5 Sensor Chips, supplied by Biacore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/streptavidin+coated+sensor+chip/us11718657-454-11-0
Average 90 stars, based on 1 article reviews
streptavidin-coupled cm-5 sensor chips - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
Danaher Inc 5 spr sensor chip
KEY RESOURCES TABLE
5 Spr Sensor Chip, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cm-5+sensor+chip/Sensor+Chip+CM5%2C+pack+of+10/pmc06726503-123-0-5
Average 96 stars, based on 1 article reviews
5 spr sensor chip - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

Image Search Results


KEY RESOURCES TABLE

Journal: Structure (London, England : 1993)

Article Title: Structural adaptation in its orphan domain engenders betaglycan with an alternate mode of growth factor binding relative to endoglin

doi: 10.1016/j.str.2019.06.010

Figure Lengend Snippet: KEY RESOURCES TABLE

Article Snippet: CM-5 SPR sensor chip , GE Lifesciences , Cat# 29149604.

Techniques: Recombinant, Software