Review




Structured Review

Cell Marque cc1 64
Cc1 64, supplied by Cell Marque, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/64+cc1/pm41803273-65-180-190
Average 86 stars, based on 1 article reviews
cc1 64 - by Bioz Stars, 2026-09
86/100 stars

Images

Related Articles

Immunohistochemical staining:

Article Title: SMARCA4-deficient carcinoma of the head and neck region: report of 8 new sinonasal and non-sinonasal cases and literature review.
Article Snippet: Both probes were mixed with water and LSI/WCP hybridization buffer (Vysis/Abbott Molecular, IL, USA) in a 1:1:1:7 ratio, respectively. .. Table 1 Antibodies used for immunohistochemical study RTU ready to use, CC1 EDTA buffer pH 8.6 at 95 °C, CC2 citrate buffer pH 6.0 at 92 °C; min minutes; EnVision High pH 9.0 at 97 °C; EnVision Low pH 6.0 at 97 °C Antibody specificity Clone Dilution Antigen retrieval/time Source SMARCA4 EPNCIR111A 1:1000 CC1/52 min Abcam SMARCB1 MRQ-27 RTU CC1/52 min Ventana SMARCA2 Polyclonal 1:200 CC2/56 min Atlas Antibodies AB AE1/3 AE1/AE3 + PCK26 RTU CC1/20 min Ventana OSCAR IsoType:IgG2a 1:100 EnVision High pH/30 min Covance CAM5.2 CAM5.2 RTU CC1/36 min Ventana Claudin 4 3E2C1 1:200 CC1/52 min Thermo Scientific– Life Technologies MOC-31 MOC-31 1:50 CC1/52 min Abcam CK5/6 D5/16B4 1:50 EnVision High pH/30 min Dako CK7 OV-TL 12/30 RTU EnVision High pH/30 min Dako p63 DAK-p63 RTU EnVision Low pH/30 min Dako p40 BC28 RTU CC1/52 min Biocare Medical Synaptophysin SP11 RTU CC1/52 min Dako Chromogranin A DAK-A3 1:100 CC1/20 min Dako Cytomation CD56 123C3 RTU CC1/64 min Ventana INSM1 A-8 1:1000 CC1/64 min Santa Cruz p16 R15A 1:100 EnVision FLEX TRS High pH/30min DB Biotech NUT C52B1 1:100 CC1/64 min Cell Signaling SOX 10 SP267 RTU CC1/64 min Cell Marque S-100 protein Polyclonal RTU EnVision High pH/30 min Dako p53 DO-7 RTU EnVision High pH/30 min Ventana Ki-67 MIB-1 RTU EnVision High pH/30 min Dako MyoD1 EP212 RTU CC2/68 Ventana Desmin D33 1:200 EnVision High pH/30 min Dako An appropriate amount of mixed probe was applied on the specimens, covered with a glass cover slip, and sealed with rubber cement. .. The slide was incubated in the ThermoBrite instrument (StatSpin/Iris Sample Processing, Westwood, MA, USA) with codenaturation parameters of 85 °C for 8 min and hybridization parameters of 37 °C for 16 h. The rubber-cemented cover slip was then removed, and the slide was placed in posthybridization wash solution (2 × SSC/0.3% NP-40) at 72 °C for 2 min.



Similar Products

86
Cell Marque cc1 64
Cc1 64, supplied by Cell Marque, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/64+cc1/pm41803273-65-180-190
Average 86 stars, based on 1 article reviews
cc1 64 - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Cell Marque cc1/64 min
Antibodies Used for Immunohistochemical Study
Cc1/64 Min, supplied by Cell Marque, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/cc1+64+min/pmc11556814-5-6-9
Average 90 stars, based on 1 article reviews
cc1/64 min - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Biocare Medical ultra cc1 standard (64 min) at 95 °c
Clone, dilution, pretreatment, and vendor of the antibodies used for the stains that we applied.
Ultra Cc1 Standard (64 Min) At 95 °C, supplied by Biocare Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/ultra+cc1+standard++64+min++at+95++c/pmc10527570-0-5-19
Average 90 stars, based on 1 article reviews
ultra cc1 standard (64 min) at 95 °c - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Agilent technologies autostainer (cc1, 64'/16′
List of antibodies used in this study.
Autostainer (Cc1, 64'/16′, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/pmc08262240-9-11-5
Average 90 stars, based on 1 article reviews
autostainer (cc1, 64'/16′ - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

98
Santa Cruz Biotechnology ultra cc1 64
List of antibodies used in this study.
Ultra Cc1 64, supplied by Santa Cruz Biotechnology, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/cyclin+D1/pm33888988-78-91-76
Average 98 stars, based on 1 article reviews
ultra cc1 64 - by Bioz Stars, 2026-09
98/100 stars
  Buy from Supplier

97
Santa Cruz Biotechnology cc1
Immunohistochemistry
Cc1, supplied by Santa Cruz Biotechnology, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/Cdk6+Antibody/pmc06158019-17-10-15
Average 97 stars, based on 1 article reviews
cc1 - by Bioz Stars, 2026-09
97/100 stars
  Buy from Supplier

94
Cell Signaling Technology Inc cc1
Immunohistochemistry
Cc1, supplied by Cell Signaling Technology Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cc1+64/Phospho-Rb+(Ser795)+Antibody/pmc06158019-13-10-15
Average 94 stars, based on 1 article reviews
cc1 - by Bioz Stars, 2026-09
94/100 stars
  Buy from Supplier

Image Search Results


Antibodies Used for Immunohistochemical Study

Journal: The American Journal of Surgical Pathology

Article Title: Discovery of Novel TULP4/ACTN4/EWSR1/ACTB::MYB and ESRRG::DNM3 Fusions Expands Molecular Landscape of Adenoid Cystic Carcinoma Beyond Fusions Between MYB/MYBL1 and NFIB Genes

doi: 10.1097/PAS.0000000000002304

Figure Lengend Snippet: Antibodies Used for Immunohistochemical Study

Article Snippet: SOX10 , SP267 , RTU , CC1/64 min , Cell Marque.

Techniques: Immunohistochemical staining

Clone, dilution, pretreatment, and vendor of the antibodies used for the stains that we applied.

Journal: Diagnostics

Article Title: Immunohistochemical Staining Characteristics of Low-Grade Invasive Ductal Carcinoma Using the ADH5 Cocktail (CK5/14, P63, and CK7/18): A Potential Interpretative Pitfall

doi: 10.3390/diagnostics13182966

Figure Lengend Snippet: Clone, dilution, pretreatment, and vendor of the antibodies used for the stains that we applied.

Article Snippet: Anti-CK 5/14 , 34βE12 , Ultra CC1 standard (64 min) at 95 °C , IgG1/kappa , Mouse monoclonal , Biocare medical/CA.

Techniques:

List of antibodies used in this study.

Journal: Pathology and Oncology Research

Article Title: The Clinicopathological Significance of YAP/TAZ Expression in Hepatocellular Carcinoma with Relation to Hypoxia and Stemness

doi: 10.3389/pore.2021.604600

Figure Lengend Snippet: List of antibodies used in this study.

Article Snippet: Ki-67 (mouse mAb; MIB-1) , Dako (Glostrup, Denmark) , 1:100 , Autostainer (CC1, 64'/16′).

Techniques:

Immunohistochemistry

Journal: Cancer cell

Article Title: Identification of Therapeutic Targets in Rhabdomyosarcoma Through Integrated Genomic, Epigenomic, and Proteomic Analyses

doi: 10.1016/j.ccell.2018.07.012

Figure Lengend Snippet: Immunohistochemistry

Article Snippet: CDK6 , RUO , Ultra , MM , 1:25 , CC1–64 min , None , Santa Cruz; sc7961.

Techniques: Immunohistochemical staining, Biomarker Discovery, Amplification, Blocking Assay

Immunohistochemistry

Journal: Cancer cell

Article Title: Identification of Therapeutic Targets in Rhabdomyosarcoma Through Integrated Genomic, Epigenomic, and Proteomic Analyses

doi: 10.1016/j.ccell.2018.07.012

Figure Lengend Snippet: Immunohistochemistry

Article Snippet: pRB , RUO , Ultra , RP , 1:100 , CC1–64 min , None , Cell Signaling; 9301S.

Techniques: Immunohistochemical staining, Biomarker Discovery, Amplification, Blocking Assay