1d bloch equation simulation (MathWorks Inc)
Structured Review

1d Bloch Equation Simulation, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/bloch+equation+simulations/pmc11971512-40-1-15
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "3D joint T 1 /T 1 ρ /T 2 mapping and water‐fat imaging for contrast‐agent free myocardial tissue characterization at 1.5T"
Article Title: 3D joint T 1 /T 1 ρ /T 2 mapping and water‐fat imaging for contrast‐agent free myocardial tissue characterization at 1.5T
Journal: Magnetic Resonance in Medicine
doi: 10.1002/mrm.30397
Figure Legend Snippet: 3D joint T 1 / T 1 ρ / T 2 mapping and water/fat imaging sequence schematic diagram. Volume 1: IR (TI = 250 ms ), Volume 2: no‐preparation, Volume 3: T 1 ρ ‐preparation (spin‐lock duration = 40 ms and spin‐lock amplitude = 400 Hz ), Volume 4: T 2 ‐preparation (duration = 40 ms ), Volume 5: no preparation. Non‐rigid motion correction with patch‐based regularization is used to reconstruct 3D IP/OP HB images; water and fat images are generated from IP/OP images through a fat‐water separation algorithm, and T 1 / T 1 ρ / T 2 maps are estimated from water images by dictionary matching via a Bloch simulation of the proposed 3D sequence.
Techniques Used: Imaging, Sequencing, Generated
Related Articles
Selection:Article Title: Fast 3D T2 -weighted imaging using variable flip angle transition into driven equilibrium (3D T2 -TIDE) balanced SSFP for prostate imaging at 3T. Article Snippet: .. Bloch Simulations In order to understand parameter selection, image contrast, and spatial resolution, Sequencing:Article Title: Fast 3D T2 -weighted imaging using variable flip angle transition into driven equilibrium (3D T2 -TIDE) balanced SSFP for prostate imaging at 3T. Article Snippet: .. Bloch Simulations In order to understand parameter selection, image contrast, and spatial resolution, Article Title: A characterization of ABL-101 as a potential tracer for clinical fluorine-19 MRI. Article Snippet: .. For theTSE pulse sequence, Article Title: Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla. Article Snippet: .. Numerical Simulations To optimize the TSE pulse sequence, Magnetic Resonance Imaging:Article Title: Simultaneous fat-free isotropic 3D anatomical imaging and T 2 mapping of knee cartilage with lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses. Article Snippet: .. |