Review




Structured Review

Applied Precision Inc arrayworx biochip scanner
Arrayworx Biochip Scanner, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/10__1007_slash_s12257___020___0342___9-64-7-10
Average 90 stars, based on 1 article reviews
arrayworx biochip scanner - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Sequencing:

Article Title: Microarray of DNA–protein complexes on poly-3-hydroxybutyrate surface for pathogen detection
Article Snippet: A novel strategy was developed for the specific immobilization of DNA probes on poly-3-hydroxybutyrate (PHB) surface by using the substrate-binding domain (SBD) of PHB depolymerase as an active binding motif.. To demonstrate whether this method can be used for the detection of clinical pathogens, the pathogen-specific biotin-labeled DNA probes were immobilized via core streptavidin (cSA) fused to the SBD.. The pathogen-specific 15-mer oligonucleotide probes were designed for four model pathogens, while the target DNAs were prepared by PCR using universal primers.

Derivative Assay:

Article Title: Microarray of DNA–protein complexes on poly-3-hydroxybutyrate surface for pathogen detection
Article Snippet: A novel strategy was developed for the specific immobilization of DNA probes on poly-3-hydroxybutyrate (PHB) surface by using the substrate-binding domain (SBD) of PHB depolymerase as an active binding motif.. To demonstrate whether this method can be used for the detection of clinical pathogens, the pathogen-specific biotin-labeled DNA probes were immobilized via core streptavidin (cSA) fused to the SBD.. The pathogen-specific 15-mer oligonucleotide probes were designed for four model pathogens, while the target DNAs were prepared by PCR using universal primers.

Labeling:

Article Title: Microarray of DNA–protein complexes on poly-3-hydroxybutyrate surface for pathogen detection
Article Snippet: A novel strategy was developed for the specific immobilization of DNA probes on poly-3-hydroxybutyrate (PHB) surface by using the substrate-binding domain (SBD) of PHB depolymerase as an active binding motif.. To demonstrate whether this method can be used for the detection of clinical pathogens, the pathogen-specific biotin-labeled DNA probes were immobilized via core streptavidin (cSA) fused to the SBD.. The pathogen-specific 15-mer oligonucleotide probes were designed for four model pathogens, while the target DNAs were prepared by PCR using universal primers.

Hybridization:

Article Title: High-throughput identification of clinically important bacterial pathogens using DNA microarray.
Article Snippet: Rapid and accurate detection of pathogenic bacteria is important for the treatment of patients with suitable antibiotics.. Here we report the development of a diagnostic DNA microarray for the highthroughput identification of 39 pathogenic bacteria selected based on their high prevalence rate and/or difficulty of cultivation.. The 23S ribosomal DNA and 16S–23S rDNA intergenic spacer region were used as target DNAs for pathogen detection.



Similar Products

90
Applied Precision Inc arrayworx biochip scanner
Arrayworx Biochip Scanner, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/10__1007_slash_s12257___020___0342___9-64-7-10
Average 90 stars, based on 1 article reviews
arrayworx biochip scanner - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Applied Precision Inc modified arrayworx® biochip scanner
Modified Arrayworx® Biochip Scanner, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/pm26110969-77-11-14
Average 90 stars, based on 1 article reviews
modified arrayworx® biochip scanner - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Applied Precision Inc fluorescent microarray scanner arrayworx e-biochip reader
a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA <t>microarray</t> scanner.
Fluorescent Microarray Scanner Arrayworx E Biochip Reader, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/fluorescent+microarray+scanner+arrayworx+e+biochip+reader/pmc04334502-73-7-13
Average 90 stars, based on 1 article reviews
fluorescent microarray scanner arrayworx e-biochip reader - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Applied Precision Inc modified arrayworx biochip scanner
a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA <t>microarray</t> scanner.
Modified Arrayworx Biochip Scanner, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/pm23581968-81-14-17
Average 90 stars, based on 1 article reviews
modified arrayworx biochip scanner - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Applied Precision Inc modified biochip scanner arrayworx
a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA <t>microarray</t> scanner.
Modified Biochip Scanner Arrayworx, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/pm23570236-51-11-14
Average 90 stars, based on 1 article reviews
modified biochip scanner arrayworx - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Applied Precision Inc modified biochip scanner (arrayworx
a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA <t>microarray</t> scanner.
Modified Biochip Scanner (Arrayworx, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/10__1021_slash_ac400743w-51-11-14
Average 90 stars, based on 1 article reviews
modified biochip scanner (arrayworx - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Applied Precision Inc laser scanner arrayworx e standard biochip reader
a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA <t>microarray</t> scanner.
Laser Scanner Arrayworx E Standard Biochip Reader, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/arrayworx+biochip+scanner/modified+biochip+scanner+arrayworx/pmc03236191-218-7-14
Average 90 stars, based on 1 article reviews
laser scanner arrayworx e standard biochip reader - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA microarray scanner.

Journal: PLoS ONE

Article Title: A Microfluidic Platform for High-Throughput Multiplexed Protein Quantitation

doi: 10.1371/journal.pone.0117744

Figure Lengend Snippet: a) microfluidic design: the device consists of two PDMS layers: flow (blue) and control (red). The chip is an array of eight rows by 48 columns for 384 unit cells. Each unit cell is composed of: two antibody chambers divided by a reaction chamber (1–2), 4 MITOMI buttons (3), a valve that segregates the unit cells (4), a valve that separates antibody and reaction chambers (5) and a valve for releasing pressure in the antibody chambers (6). b) The PDMS chip is aligned to an epoxy-functionalized slide onto which primary and secondary antibodies were spotted. c) Assay details: schematic of the unit cell and cross section of a button region: i) functionalization of the surface: BSA-biotin is flowed though the chip followed by neutravidin. Next, the buttons are closed and BSA-biotin flowed again to passivate all neutravidin molecules except for those located underneath the MITOMI buttons, ii) the biotinylated primary antibody is allowed to diffuse into the MITOMI detection chamber and is bound by neutravidin immobilizing it in the MITOMI detection regions, iii) the sample is flown through the device and antigens are captured by the surface immobilized antibodies, iv) finally, the fluorescently labeled secondary antibody is allowed to diffuse into the MITOMI area, binds to the antigen if present, and is trapped by MITOMI. The entire device is then quantitated using a DNA microarray scanner.

Article Snippet: The microfluidic device was scanned using a fluorescent microarray scanner (ArrayWorx e-Biochip Reader, Applied Precision, USA).

Techniques: Control, Labeling, Microarray