Review




Structured Review

Omics Data Automation high throughput screening
High Throughput Screening, supplied by Omics Data Automation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/high+screening+throughput/pm42277912-503-8-1
Average 86 stars, based on 1 article reviews
high throughput screening - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

other:

Article Title: CRISPR diagnostics: from trans-nuclease activity to cancer diagnosis.
Article Snippet: Integrating multi-omics data, machine learning-guided crRNA design, and high-throughput screening of Cas variants could democratize ultra-specific diagnostics.

Article Title: VaLPAS: Leveraging variation in experimental multi-omics data to elucidate protein function
Article Snippet: The potential of this approach has long been recognized in the analysis of high-throughput omics data ( ; ), but does not have a standard approach or framework to explore and characterize these associations.

Expressing:

Article Title: System biological and experimental validation of miRNAs target genes involved in colorectal cancer radiation response
Article Snippet: Background and objectives: Prediction of response to radiotherapy in colorectal cancer (CRC) patients is of great interest that protects radiation-resistant patients from imposing to high doses of X radiation. miRNAs and their target genes are potential candidates as biomarkers of cancer.. Microarray provides a high-throughput analysis of cell transcriptome; however, this very complex data needs to be interpreted via network-based approaches.. In this study, miRNAs target genes involved in the CRC radiation response were validated through a system biological and experimental manner.

High Throughput Screening Assay:

Article Title: Integrative Multiomics Insights into the Genetic and Epigenetic Architecture of Alzheimer's Disease.
Article Snippet: Alzheimer’s disease (AD) is a multifactorial neurodegenerative disorder driven by complex genetic and molecular interactions.. Despite major advances in genomics, current discoveries explain less than 40% of AD heritability, underscoring the need for integrative approaches that capture cross-omic regulation.. Here, we propose a multiomics integration framework combining genomic, epigenomic, and transcriptomic data sets to identify convergent molecular signatures underlying AD pathogenesis.



Similar Products

97
Sartorius AG ique high throughput screening flow cytometer
Ique High Throughput Screening Flow Cytometer, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/iQue+3+Advanced+Flow+Cytometry+System/pmc13780538-154-9-14
Average 97 stars, based on 1 article reviews
ique high throughput screening flow cytometer - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

96
Revvity opera phenix high throughput spinning disk confocal microscope
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Opera Phenix High Throughput Spinning Disk Confocal Microscope, supplied by Revvity, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/Opera+Phenix+Plus+high-content+screening+system/bio_rxiv__64898__2026__10__26__761693-424-10-17
Average 96 stars, based on 1 article reviews
opera phenix high throughput spinning disk confocal microscope - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

94
Danaher Inc flipr penta
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Flipr Penta, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/FLIPR+Penta+High-Throughput+Cellular+Screening+System/pm42906386-232-42-52
Average 94 stars, based on 1 article reviews
flipr penta - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

96
TargetMol fda drug library high throughput screen
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Fda Drug Library High Throughput Screen, supplied by TargetMol, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/FDA-Approved+Drug+Library/pm42880285-1948-0-11
Average 96 stars, based on 1 article reviews
fda drug library high throughput screen - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

94
Danaher Inc flipr system
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Flipr System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/FLIPR+Penta+High-Throughput+Cellular+Screening+System/pm42869148-182-3-5
Average 94 stars, based on 1 article reviews
flipr system - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Danaher Inc flipr high throughput calcium imaging system
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Flipr High Throughput Calcium Imaging System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/FLIPR+Penta+High-Throughput+Cellular+Screening+System/pm42810298-152-14-19
Average 94 stars, based on 1 article reviews
flipr high throughput calcium imaging system - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Danaher Inc flipr penta system
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Flipr Penta System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/FLIPR+Penta+High-Throughput+Cellular+Screening+System/pmc13649475-50-5-8
Average 94 stars, based on 1 article reviews
flipr penta system - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

86
Omics Data Automation high throughput screening
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
High Throughput Screening, supplied by Omics Data Automation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/high+screening+throughput/pm42277912-503-8-1
Average 86 stars, based on 1 article reviews
high throughput screening - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

99
Twist Bioscience throughput screening libraries
(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera <t>Phenix</t> <t>high-throughput</t> <t>microscope.</t> The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.
Throughput Screening Libraries, supplied by Twist Bioscience, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/throughput+screening/Libraries/pm42168701-316-1-11
Average 99 stars, based on 1 article reviews
throughput screening libraries - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

Image Search Results


(A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera Phenix high-throughput microscope. The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.

Journal: bioRxiv

Article Title: Oncogenic PIK3CA mutations cause lineage-selective niche corruption

doi: 10.64898/2026.10.26.761693

Figure Lengend Snippet: (A) Experimental workflow for longitudinal imaging of venous organoid differentiation and HGF treatments. Isogenic wild-type ( PIK3CA WT/WT ) and heterozygous H1047R-mutant ( PIK3CA WT/H1047R ) iPSCs were differentiated in microwell-patterned 96-well Elplasia plates. Following differentiation, organoids received vehicle (DMSO) or HGF (0.1, 1 or 10 nM) for 48 h, with medium and treatment replenished after 24 h. Brightfield and endogenous mEGFP-tagged VE-cadherin images were acquired every 4 h on an Opera Phenix high-throughput microscope. The imaging configuration comprised 12 fields of view (FOV) per well, 11 z-planes and two channels (brightfield and green). (B) Image analysis pipeline for quantifying organoid spatial movement. Following microwell segmentation, organoid contact patterns were tracked along three concentric rings (R1–R3), each divided into 360 angular bins of 1°. Each bin was classified as having or lacking organoid contact at each time point. Contact turnover was calculated between each pair of consecutive time points as the number of angular bins that gained or lost organoid contact, divided by the total number of bins (360). This was calculated separately for each of the three concentric rings (R1-R3), and the maximum turnover across rings retained for each interval to capture movement or shape changes affecting only one ring. (C,E) Heatmaps of contact turnover over the 48 h treatment period in H1047R-mutant (C) and wild-type (E) venous organoids exposed to vehicle or increasing HGF concentrations, with image capture every 4 h. (D,F) Distribution of activity frequencies in H1047R-mutant (D) and wild-type (F) organoids. Individual organoids were classified as never active (0% of valid intervals), occasionally active (>0–34%), repeatedly active (>34–67%) or frequently active (>67–100%). Bars show the percentage of organoids in each category, with exact values indicated above the bars. Data in C-F are representative of two independent iPSC clones genotype, with 29-50 organoids retained per well (clone x genotype x condition) after filtering. All brightfield images represent minimal intensity projections. Additional data are included in Fig. S10.

Article Snippet: Scaffold-free organoids seeded in Elplasia plates were imaged using an Opera Phenix high-throughput spinning disk confocal microscope (Revvity).

Techniques: Imaging, Mutagenesis, Organoids, Brightfield, Sample Throughput, Microscopy, Analysis, Activity Assay, Clone Assay, IPSC