ScandiDos 2d diode arrays delta4 discover
2d Diode Arrays Delta4 Discover, supplied by ScandiDos, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/delta4+phantom/pm32416282-108-0-9
Average 90 stars, based on 1 article reviews
2d diode arrays delta4 discover - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

other:

Article Title: Comparative analysis of radiotherapy modalities and techniques for left breast cancer: dose coverage, setup accuracy, with patient-specific selection criteria for applying deep inspiration breath hold.
Article Snippet: To compare dosimetric outcomes between Free Breath (FB) and Deep Inspiration Breath Hold (DIBH) across different radiotherapy modalities, establish patient selection criteria for DIBH, and optimizing the setup margin (SM) in left breast cancer treatment.. 26 patients with left breast cancer were studied at CRO, Aviano in Italy.. FB and DIBH simulations were done using CT with a real-time position management system.

Article Title: A novel protocol for parametrization of a beam model for small stereotactic beams.
Article Snippet: For example, Xue et al. 38 showed EPID-evaluated stereotactic VMAT plans with GPR (2%, 2 mm) between 96%–98%.Also,Vieillevigne et al.13 presented an optimal DLG with an GPR agreement close to 100% with 2%, 2 mm passing criteria using the Delta4 Phantom (Scandidos, Uppsala, Sweden).

Article Title: Fixed-point mammalian spine-like apparatus that provides an accurate and fixed alignment point of reference for pre-treatment CT while phantom and radiation detectors of a dynamic radiation oncological phantom system are in motion and a tumor tracking block with a target object of variable size, shape, and density and metal fiducial markers used to mark tumors in human treatment
Article Snippet: As the lungs and inner organs move with respiration, so moves the dynamic phantom (such as a Delta4 by Scandidos and the Hexamotion system or the ArcCheck by SunNuclear and the CIRS motion platform), but with no fixed structure of reference, the CT acquired data is extremely high in error if taken while moving, or it has to be taken with no motion taking place.

Article Title: Same-Day Magnetic Resonance-Guided Single-Fraction Stereotactic Body Radiation Therapy for Painful Non-Spine Bone Metastases – A Single-Center Study (“BONE SHOT”)
Article Snippet: After treatment, the adapted treatment plans were verified with measurements in the Delta4 phantom (Scandidos, Uppsala, Sweden).

Article Title: A novel protocol for parametrization of a beam model for small stereotactic beams
Article Snippet: Also, Vieillevigne et al. presented an optimal DLG with an GPR agreement close to 100% with 2%, 2 mm passing criteria using the Delta4 Phantom (Scandidos, Uppsala, Sweden).

Article Title: Fixed-point mammalian spine-like apparatus that provides an accurate and fixed alignment point of reference for pre-treatment CT while phantom and radiation detectors of a dynamic radiation oncological phantom system are in motion and a tumor tracking block with a target object of variable size, shape, and density and metal fiducial markers used to mark tumors in human treatment
Article Snippet: The Scandidos Delta4 phantom system (D4) is referred to below as “Hexamotion and Accuray Radixact” with synchrony feature, but can any LINAC or dynamic phantom (such as SunNuclear's CIRS motion platform or any other motion platform and, for that matter, any LINAC, such as a LIANC model from Varian or Elekta or any other LINAC system, be that of X-ray, gamma ray, neutron, or proton treatment plan delivery) that may come into existence.

Article Title: Fixed-point mammalian spine-like apparatus that provides an accurate and fixed alignment point of reference for pre-treatment CT while phantom and radiation detectors of a dynamic radiation oncological phantom system are in motion and a tumor tracking block with a target object of variable size, shape, and density and metal fiducial markers used to mark tumors in human treatment
Article Snippet: In this figure, the phantom system 230 demonstrates relative placement of the fixed-point mammalian spine-like apparatus 200 when attached, via connection device 220, to a Scandidos Delta4 phantom 230.

Imaging:

Article Title: Evaluation of multileaf collimator driving accuracy in helical rotational irradiation system: Quantitative analysis of leaf open time during treatment.
Article Snippet: .. Table 1 shows the number of treatment plans, PSQA assessments,and treatment sessions performed.PSQA was conducted using gamma analysis with the Delta4 Phantom+ (ScandiDos AB,Uppsala,Sweden), chamber verification with the A1SL ionization chamber (Standard Imaging, Middleton, WI, USA), and film verification using Gafchromic film (Ashland, Bridgewater, NJ, USA). ..



Similar Products

90
Elekta 2d diode array
2d Diode Array, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/mr+compatible+arccheck+diode+array/pm39422882-3244-13-18
Average 90 stars, based on 1 article reviews
2d diode array - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation 2d diode array detector mapcheck2
2d Diode Array Detector Mapcheck2, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/mapcheck/pm37408321-89-15-20
Average 90 stars, based on 1 article reviews
2d diode array detector mapcheck2 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation the 2d diode array
The 2d Diode Array, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/2d+diode+array+mapcheck/pmc09084591-73-22-7
Average 90 stars, based on 1 article reviews
the 2d diode array - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation srs mapcheck 2d diode array
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
Srs Mapcheck 2d Diode Array, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/srs+mapcheck+diode+array/pmc09359048-120-10-18
Average 90 stars, based on 1 article reviews
srs mapcheck 2d diode array - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
ScandiDos 2d diode arrays delta4 discover
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
2d Diode Arrays Delta4 Discover, supplied by ScandiDos, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/delta4+phantom/pm32416282-108-0-9
Average 90 stars, based on 1 article reviews
2d diode arrays delta4 discover - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Agilent technologies two diode array detectors (1d: g4212a; 2d: g4212b)
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
Two Diode Array Detectors (1d: G4212a; 2d: G4212b), supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/pmc08043762-85-22-42
Average 90 stars, based on 1 article reviews
two diode array detectors (1d: g4212a; 2d: g4212b) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation 2d array diode detector mapcheck2tm
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
2d Array Diode Detector Mapcheck2tm, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/mapcheck2tm+detector+array/pm31153402-48-7-12
Average 90 stars, based on 1 article reviews
2d array diode detector mapcheck2tm - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TomoTherapy 2d diode array [232 diodes; detector spacing, (4 along the lateral (longitudinal) profile direction]
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
2d Diode Array [232 Diodes; Detector Spacing, (4 Along The Lateral (Longitudinal) Profile Direction], supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/diode+array/pmc06530616-189-23-34
Average 90 stars, based on 1 article reviews
2d diode array [232 diodes; detector spacing, (4 along the lateral (longitudinal) profile direction] - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation 2d array of ionization chambers/diodes sunnuclear mapcheck/arccheck
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
2d Array Of Ionization Chambers/Diodes Sunnuclear Mapcheck/Arccheck, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/2d+diode+array+mapcheck/pm29521520-100-10-20
Average 90 stars, based on 1 article reviews
2d array of ionization chambers/diodes sunnuclear mapcheck/arccheck - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Scanditronix gmbh 2d array of ionization chambers/diodes scanditronix delta4
(a) The StereoPHAN phantom and the <t>SRS</t> <t>mapCHECK</t> diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green
2d Array Of Ionization Chambers/Diodes Scanditronix Delta4, supplied by Scanditronix gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/the+2d+diode+array/2d+array+of+ionization+chambers+diodes+scanditronix+delta4/pm29521520-100-13-18
Average 90 stars, based on 1 article reviews
2d array of ionization chambers/diodes scanditronix delta4 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


(a) The StereoPHAN phantom and the SRS mapCHECK diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green

Journal: Journal of Applied Clinical Medical Physics

Article Title: Impact of systematic MLC positional uncertainties on the quality of single‐isocenter multi‐target VMAT‐SRS treatment plans

doi: 10.1002/acm2.13708

Figure Lengend Snippet: (a) The StereoPHAN phantom and the SRS mapCHECK diode array positioned on the couch for CT scanning. (b) An axial CT slice of the diode array with the TPS‐calculated dose distribution corresponding to the clinically used leaf offset parameter. Contours legend: targets: red, blue, and purple; brainstem‐like critical organ: green

Article Snippet: Moreover, the commercially available StereoPHAN phantom in combination with the SRS mapCHECK 2D diode array (both produced by Sun Nuclear Corp., Melbourne, FL) were used for plan verification of a challenging VMAT‐SRS case and results are compared with TPS‐calculated dose distributions obtained after changing the clinically used leaf offset parameter.

Techniques: