Review



size exclusion chromatography column against desalting buffer  (Cytiva Europe)


Bioz Verified Symbol Cytiva Europe is a verified supplier
Bioz Manufacturer Symbol Cytiva Europe manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86

    Structured Review

    Cytiva Europe size exclusion chromatography column against desalting buffer
    Size Exclusion Chromatography Column Against Desalting Buffer, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/pm37836637-221-25-13
    Average 86 stars, based on 1 article reviews
    size exclusion chromatography column against desalting buffer - by Bioz Stars, 2026-11
    86/100 stars

    Images

    Related Articles

    Recombinant:

    Article Title: A potent Henipavirus cross-neutralizing antibody reveals a dynamic fusion-triggering pattern of the G-tetramer
    Article Snippet: The supernatants were harvested by centrifugation at 800 × g and 5000 × g at 4 °C for 10 min and subsequently filtered through 0.22 μm syringe filters (PALL, Cat# 4612) or disposable vacuum systems (Biosharp, Cat# BS-500-XT). .. Recombinant proteins were purified on an ÄKTA Pure 150 purification system (GE Healthcare) using a 5 mL StrepTrap HP column (binding buffer: 100 mM Tris, 150 mM NaCl, and 1 mM EDTA, pH 8.0; elution buffer: 2.5 mM desthiobiotin in binding buffer); a HisTrap Excel column (binding buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 10 mM imidazole, pH 8.0; elution buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 300 mM imidazole, pH 8.0); or a HiTrap rProtein A column (binding buffer: PBS, pH 7.4; elution buffer: 0.1 M glycine, pH 3.0; neutralization buffer: 1 M Tris-HCl, pH 9.0); and buffer exchanged and stored in either PBS (137 mM NaCl, 2.7 mM KCl, 10 mM Na 2 HPO 4 , and 1.8 mM KH 2 PO 4 , pH 7.4) or TBS (50 mM Tris, 150 mM NaCl, and 10 mM EDTA, pH 8.0). .. All proteins were analyzed for purity by SDS–PAGE (Supplementary Fig. ) or high-performance liquid chromatography, and the concentration was determined using a BCA protein assay kit (Merck Millipore, Cat# 23225) or the UV 280 nm absorption method.

    Purification:

    Article Title: A potent Henipavirus cross-neutralizing antibody reveals a dynamic fusion-triggering pattern of the G-tetramer
    Article Snippet: The supernatants were harvested by centrifugation at 800 × g and 5000 × g at 4 °C for 10 min and subsequently filtered through 0.22 μm syringe filters (PALL, Cat# 4612) or disposable vacuum systems (Biosharp, Cat# BS-500-XT). .. Recombinant proteins were purified on an ÄKTA Pure 150 purification system (GE Healthcare) using a 5 mL StrepTrap HP column (binding buffer: 100 mM Tris, 150 mM NaCl, and 1 mM EDTA, pH 8.0; elution buffer: 2.5 mM desthiobiotin in binding buffer); a HisTrap Excel column (binding buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 10 mM imidazole, pH 8.0; elution buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 300 mM imidazole, pH 8.0); or a HiTrap rProtein A column (binding buffer: PBS, pH 7.4; elution buffer: 0.1 M glycine, pH 3.0; neutralization buffer: 1 M Tris-HCl, pH 9.0); and buffer exchanged and stored in either PBS (137 mM NaCl, 2.7 mM KCl, 10 mM Na 2 HPO 4 , and 1.8 mM KH 2 PO 4 , pH 7.4) or TBS (50 mM Tris, 150 mM NaCl, and 10 mM EDTA, pH 8.0). .. All proteins were analyzed for purity by SDS–PAGE (Supplementary Fig. ) or high-performance liquid chromatography, and the concentration was determined using a BCA protein assay kit (Merck Millipore, Cat# 23225) or the UV 280 nm absorption method.

    Article Title: The molecular basis underlying T cell specificity towards citrullinated epitopes presented by HLA-DR4.
    Article Snippet: Live CD19-CD14- CD3+ CD4+ HLA-DR4a-eno-15cit10-22 and/or HLA-DR4Vim-64cit59-71 tetramer binding cells were single-cell index sorted into 96-well polymerase chain reaction (PCR) plates (Eppendorf #00301286) and stored at -80 °C until use. .. The samples were dialyzed extensively in 10mM Tris pH8.0 and purified on a DEAE (Cytiva) anion exchange column, followed by size exclusion (Superdex 200, 16/600; Cytiva), hydrophobic interaction (Hi Trap SP HP; Cytiva) and anion exchange (HiTrap Q HP column; Cytiva) chromatography. .. The extracellular domains of the α- and β-chains of HLA-DR4 (HLA-DRA*01:01 and HLA-DRB1*04:01) were cloned in the lentiviral vectors pLV-EF1α-MCS-IRES-GFP and pLV-EF1α-MCS-IRES-RFP (Biosettia), respectively and HLA-DR4 lentivirus produced through cotransfection of these vectors along with viral packaging plasmids (pMD2.G, pMDLg/pRRE, pRSV-REV; Addgene) in HEK293T cells following themanufacturer’s (Biosettia) protocol.

    Binding Assay:

    Article Title: A potent Henipavirus cross-neutralizing antibody reveals a dynamic fusion-triggering pattern of the G-tetramer
    Article Snippet: The supernatants were harvested by centrifugation at 800 × g and 5000 × g at 4 °C for 10 min and subsequently filtered through 0.22 μm syringe filters (PALL, Cat# 4612) or disposable vacuum systems (Biosharp, Cat# BS-500-XT). .. Recombinant proteins were purified on an ÄKTA Pure 150 purification system (GE Healthcare) using a 5 mL StrepTrap HP column (binding buffer: 100 mM Tris, 150 mM NaCl, and 1 mM EDTA, pH 8.0; elution buffer: 2.5 mM desthiobiotin in binding buffer); a HisTrap Excel column (binding buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 10 mM imidazole, pH 8.0; elution buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 300 mM imidazole, pH 8.0); or a HiTrap rProtein A column (binding buffer: PBS, pH 7.4; elution buffer: 0.1 M glycine, pH 3.0; neutralization buffer: 1 M Tris-HCl, pH 9.0); and buffer exchanged and stored in either PBS (137 mM NaCl, 2.7 mM KCl, 10 mM Na 2 HPO 4 , and 1.8 mM KH 2 PO 4 , pH 7.4) or TBS (50 mM Tris, 150 mM NaCl, and 10 mM EDTA, pH 8.0). .. All proteins were analyzed for purity by SDS–PAGE (Supplementary Fig. ) or high-performance liquid chromatography, and the concentration was determined using a BCA protein assay kit (Merck Millipore, Cat# 23225) or the UV 280 nm absorption method.

    Neutralization:

    Article Title: A potent Henipavirus cross-neutralizing antibody reveals a dynamic fusion-triggering pattern of the G-tetramer
    Article Snippet: The supernatants were harvested by centrifugation at 800 × g and 5000 × g at 4 °C for 10 min and subsequently filtered through 0.22 μm syringe filters (PALL, Cat# 4612) or disposable vacuum systems (Biosharp, Cat# BS-500-XT). .. Recombinant proteins were purified on an ÄKTA Pure 150 purification system (GE Healthcare) using a 5 mL StrepTrap HP column (binding buffer: 100 mM Tris, 150 mM NaCl, and 1 mM EDTA, pH 8.0; elution buffer: 2.5 mM desthiobiotin in binding buffer); a HisTrap Excel column (binding buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 10 mM imidazole, pH 8.0; elution buffer: 50 mM Tris, 150 mM NaCl, 10 mM EDTA, and 300 mM imidazole, pH 8.0); or a HiTrap rProtein A column (binding buffer: PBS, pH 7.4; elution buffer: 0.1 M glycine, pH 3.0; neutralization buffer: 1 M Tris-HCl, pH 9.0); and buffer exchanged and stored in either PBS (137 mM NaCl, 2.7 mM KCl, 10 mM Na 2 HPO 4 , and 1.8 mM KH 2 PO 4 , pH 7.4) or TBS (50 mM Tris, 150 mM NaCl, and 10 mM EDTA, pH 8.0). .. All proteins were analyzed for purity by SDS–PAGE (Supplementary Fig. ) or high-performance liquid chromatography, and the concentration was determined using a BCA protein assay kit (Merck Millipore, Cat# 23225) or the UV 280 nm absorption method.

    other:

    Article Title: Immunochromatographic Strip Based on Tetrahedral DNA Immunoprobe for the Detection of Aflatoxin B 1 in Rice Bran Oil
    Article Snippet: Phosphate-buffered saline (PBS, 10 mmol/L, pH 7.4), borate buffer solution (BBS, 0.05 mol/L, pH 8.0), TM buffer (20 mol/L Tris, 50 mol/L MgCl 2 , pH 8.0), and carbonate buffer solution (CBS, 0.05 mol/L, pH 9.6) were provided by Cytiva Co., Ltd. (Shanghai, China); bran oil was commercially purchased from the local supermarket.

    Chromatography:

    Article Title: The molecular basis underlying T cell specificity towards citrullinated epitopes presented by HLA-DR4.
    Article Snippet: Live CD19-CD14- CD3+ CD4+ HLA-DR4a-eno-15cit10-22 and/or HLA-DR4Vim-64cit59-71 tetramer binding cells were single-cell index sorted into 96-well polymerase chain reaction (PCR) plates (Eppendorf #00301286) and stored at -80 °C until use. .. The samples were dialyzed extensively in 10mM Tris pH8.0 and purified on a DEAE (Cytiva) anion exchange column, followed by size exclusion (Superdex 200, 16/600; Cytiva), hydrophobic interaction (Hi Trap SP HP; Cytiva) and anion exchange (HiTrap Q HP column; Cytiva) chromatography. .. The extracellular domains of the α- and β-chains of HLA-DR4 (HLA-DRA*01:01 and HLA-DRB1*04:01) were cloned in the lentiviral vectors pLV-EF1α-MCS-IRES-GFP and pLV-EF1α-MCS-IRES-RFP (Biosettia), respectively and HLA-DR4 lentivirus produced through cotransfection of these vectors along with viral packaging plasmids (pMD2.G, pMDLg/pRRE, pRSV-REV; Addgene) in HEK293T cells following themanufacturer’s (Biosettia) protocol.



    Similar Products

    98
    Bio-Rad bio spin 6 tris buffer size exclusion columns
    Bio Spin 6 Tris Buffer Size Exclusion Columns, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/Tris/pmc12755392-360-6-12
    Average 98 stars, based on 1 article reviews
    bio spin 6 tris buffer size exclusion columns - by Bioz Stars, 2026-11
    98/100 stars
      Buy from Supplier

    99
    Thermo Fisher size exclusion chromatography sec buffer
    Size Exclusion Chromatography Sec Buffer, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/Phosphate/10__1002_slash_viw__20250182-51-5-23
    Average 99 stars, based on 1 article reviews
    size exclusion chromatography sec buffer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    97
    Bio-Rad enrich650 size exclusion column
    Enrich650 Size Exclusion Column, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/Lysis+Buffer/pmc11894326-245-20-24
    Average 97 stars, based on 1 article reviews
    enrich650 size exclusion column - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    99
    Thermo Fisher size exclusion buffer
    Size Exclusion Buffer, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/TRIS-HCL/pmc11705850-60-5-22
    Average 99 stars, based on 1 article reviews
    size exclusion buffer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    98
    Bio-Rad size exclusion chromatography sec buffer
    Size Exclusion Chromatography Sec Buffer, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/Tris/bio_rxiv__2024__09__24__614577-221-16-39
    Average 98 stars, based on 1 article reviews
    size exclusion chromatography sec buffer - by Bioz Stars, 2026-11
    98/100 stars
      Buy from Supplier

    90
    Millipore s200 size-exclusion buffer (1 m nacl, 10 mm hepes, 2 mm dtt, 5 mm mgcl2, and ph 7.0)
    S200 Size Exclusion Buffer (1 M Nacl, 10 Mm Hepes, 2 Mm Dtt, 5 Mm Mgcl2, And Ph 7.0), supplied by Millipore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/sephacryl+s+300/pmc11281634-102-11-34
    Average 90 stars, based on 1 article reviews
    s200 size-exclusion buffer (1 m nacl, 10 mm hepes, 2 mm dtt, 5 mm mgcl2, and ph 7.0) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    86
    Cytiva Europe size exclusion chromatography column against desalting buffer
    Size Exclusion Chromatography Column Against Desalting Buffer, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/pm37836637-221-25-13
    Average 86 stars, based on 1 article reviews
    size exclusion chromatography column against desalting buffer - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Cytiva Europe size exclusion buffer
    Size Exclusion Buffer, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/size+exclusion+buffer/size+exclusion+chromatography/pmc10502043-343-23-54
    Average 90 stars, based on 1 article reviews
    size exclusion buffer - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results