block-circulant singular value decomposition (bsvd) based method (Philips Healthcare)
Structured Review

Block Circulant Singular Value Decomposition (Bsvd) Based Method, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/singular+value+decomposition+method/block+circulant+singular+value+decomposition++bsvd++based+method/pmc06851872-12-2-10
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Effect of prolonged acquisition intervals for CT‐perfusion analysis methods in patients with ischemic stroke"
Article Title: Effect of prolonged acquisition intervals for CT‐perfusion analysis methods in patients with ischemic stroke
Journal: Medical Physics
doi: 10.1002/mp.13559
Figure Legend Snippet: The used thresholds for the calculation of the core and penumbra volumes for the different perfusion analysis methods
Techniques Used:
Figure Legend Snippet: Mean perfusion parameters with 95% confidence interval for grey matter for bSVD, ISP, and NLR. The values that are significantly different from the 1 s acquisition interval (reference) are filled and marked with an asterisk. [Color figure can be viewed at http://wileyonlinelibrary.com ]
Techniques Used:
Figure Legend Snippet: Mean perfusion parameters with 95% confidence interval for white matter for bSVD, ISP and NLR. The values that are significantly different from the 1 s acquisition interval (reference) are filled and marked with an asterisk. [Color figure can be viewed at http://wileyonlinelibrary.com ]
Techniques Used:
Figure Legend Snippet: An example of calibrated CBF maps generated using bSVD, ISP, and NLR as a function of acquisition interval. [Color figure can be viewed at http://wileyonlinelibrary.com ]
Techniques Used: Generated
Figure Legend Snippet: An example of calibrated CBV maps generated using bSVD, ISP, and NLR as a function of acquisition interval. [Color figure can be viewed at http://wileyonlinelibrary.com ]
Techniques Used: Generated
Figure Legend Snippet: An example of calibrated MTT maps generated using bSVD, ISP, and NLR as a function of acquisition interval. [Color figure can be viewed at http://wileyonlinelibrary.com ]
Techniques Used: Generated
Figure Legend Snippet: Summary maps of bSVD, ISP, and NLR as a function of acquisition interval. The infarct core is labeled red, the penumbra labeled green. This is the same patient as shown in Figs. , , . [Color figure can be viewed at http://wileyonlinelibrary.com ]
Techniques Used: Labeling
Related Articles
Blocking Assay:Article Title: Effect of prolonged acquisition intervals for CT‐perfusion analysis methods in patients with ischemic stroke Article Snippet: A commercial block‐circulant singular value decomposition (bSVD) based method ( Generated:Article Title: Effect of prolonged acquisition intervals for CT‐perfusion analysis methods in patients with ischemic stroke Article Snippet: A commercial block‐circulant singular value decomposition (bSVD) based method ( Labeling:Article Title: Effect of prolonged acquisition intervals for CT‐perfusion analysis methods in patients with ischemic stroke Article Snippet: A commercial block‐circulant singular value decomposition (bSVD) based method ( |