Review




Structured Review

Siemens AG 4-cm surface loop coil
4 Cm Surface Loop Coil, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/4+cm+surface+loop+coil/pmc11027384-5-140-146
Average 90 stars, based on 1 article reviews
4-cm surface loop coil - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: High-Resolution MRI of the Intraparotid Facial Nerve Based on a Microsurface Coil and a 3D Reversed Fast Imaging with Steady-State Precession DWI Sequence at 3T
Article Snippet: All volunteers then underwent a right parotid gland sagittal scan with the 3D-PSIF-DWI sequence by using a 4-cm-diameter surface coil (3T Loop, 4 cm; Siemens).

Article Title: Ocular MR imaging: evaluation of different coil setups in a phantom study.
Article Snippet: We investigated the following coils: a singlechannel small loop surface coil of 4-cm diameter (small loop coil); a single-channel medium loop surface coil of 6-cm diameter (medium loop coil); an array of two 6-cm loop coils arranged perpendicular to each other (double loop array coil) (tem- poromandibular joint coil, Siemens Health Care Sector, Erlangen, Germany); and an 8-channel circular polarized head coil (CP head array coil).

Article Title: MRI-Guided Vascular Access with an Active Visualization Needle
Article Snippet: We used a small 7cm loop coil (Siemens) to reduce the field-of-view, and positioned it inside a sterile bag, adjacent to the needle entry site.

Imaging:

Article Title: Magnetic resonance imaging for jawbone assessment: a systematic review
Article Snippet: Deng, 2014 11 , Fresh cadaver (1) , Posterior mandible , Geometric accuracy of inferior alveolar nerve and cortical bone for maxillofacial surgery planning , 3 T (Magnetom Trio, Siemens) , Fast gradient-echo (TR/TE 2,3/3.67 ms; flip angle 10°; matrix 448 × 448 pixels; FOV 226 × 226 mm.) , Supine conventional position , CT and digital caliper , NR , Mandibular nerve canal to cortical bone linear measurement. .. Flügge, 2016 10 , Patients (2) and dry cadaver (1) , Posterior maxilla and mandible , Imaging and geometric accuracy of hard and soft tissues for maxillofacial diagnosing , 3 T (TIM Trio, Siemens) , Gradient-echo fast low flip angle shots (FLASH) (In vivo, mandible: Matrix 64 × 64 × 28 mm (115 cm3); voxel 250 × 250 × 500 μm3; TE/TR 4.2/11 ms; flip angle 15°; three averages; scanning time 3:57 min. In vivo, maxilla: isotropic resolution 350 μm; FOV 34 cm3; TR/TE 12/4.8 ms; flip angle 15°; five averages; scanning time 6:40 min. Ex vivo, mandible: isotropic resolution 200 mm3; FOV 39 × 39 × 24 mm (36.5 cm3); TE/TR 4.3/12 ms; 2 averages; flip angle 15°; scanning time 4:38 min.) , Individually fabricated (1 mm diameter copper wire, an adjustable capacitor and crossed diodes) wireless inductively/intraoral. In vivo imaging: 4-cm surface loop coil (Siemens)/close to the cheek opposite to the intraoral coil. , CBCT , 2 (dentist > 5 years dedicated to maxillofacial radiology) , Linear measurement and tissue visibility. .. Fuglsig, 2022 12 , Cadaver specimens (12) , Posterior maxilla and mandible , Geometric accuracy of cortical bone for dental implant planning , 9.4 T (Bruker Biospec, Bruker Biospin) , Zero-Echo-Time (FOV 75 mm 3 isotropic; matrix 3663 pixels; image resolution 0.205 mm; flip angle 0.74°; TR 1.98 ms; bandwidth 2.78 kHz; projection under sampling of two; 50 averages; scan time 6 h) , 76-mm quadrature volume coil , CBCT and histology , 2 (dentist) , Cortical bone linear measurement.

Article Title: MRI assessment of experimental gliomas using 17.6 T.
Article Snippet: Introduction Using ultra-high-field contrast-enhanced magnetic resonance imaging (MRI), an increase of field strength is associated with a decrease of T1 relaxivity.. Yet, the impact of this effect on signal characteristics and contrast-enhanced pathology remains unclear.. Hence, we evaluated the potential of a 17.6-T MRI to assess contrast-enhancing parts of experimentally induced rat gliomas compared to 3 T. Methods A total of eight tumor-bearing rats were used for MRI assessments either at 17.6 T (four rats) or at 3 T (four rats) at 11 days after stereotactic implantation of F98 glioma cells into the right frontal lobe.

In Vivo:

Article Title: Magnetic resonance imaging for jawbone assessment: a systematic review
Article Snippet: Deng, 2014 11 , Fresh cadaver (1) , Posterior mandible , Geometric accuracy of inferior alveolar nerve and cortical bone for maxillofacial surgery planning , 3 T (Magnetom Trio, Siemens) , Fast gradient-echo (TR/TE 2,3/3.67 ms; flip angle 10°; matrix 448 × 448 pixels; FOV 226 × 226 mm.) , Supine conventional position , CT and digital caliper , NR , Mandibular nerve canal to cortical bone linear measurement. .. Flügge, 2016 10 , Patients (2) and dry cadaver (1) , Posterior maxilla and mandible , Imaging and geometric accuracy of hard and soft tissues for maxillofacial diagnosing , 3 T (TIM Trio, Siemens) , Gradient-echo fast low flip angle shots (FLASH) (In vivo, mandible: Matrix 64 × 64 × 28 mm (115 cm3); voxel 250 × 250 × 500 μm3; TE/TR 4.2/11 ms; flip angle 15°; three averages; scanning time 3:57 min. In vivo, maxilla: isotropic resolution 350 μm; FOV 34 cm3; TR/TE 12/4.8 ms; flip angle 15°; five averages; scanning time 6:40 min. Ex vivo, mandible: isotropic resolution 200 mm3; FOV 39 × 39 × 24 mm (36.5 cm3); TE/TR 4.3/12 ms; 2 averages; flip angle 15°; scanning time 4:38 min.) , Individually fabricated (1 mm diameter copper wire, an adjustable capacitor and crossed diodes) wireless inductively/intraoral. In vivo imaging: 4-cm surface loop coil (Siemens)/close to the cheek opposite to the intraoral coil. , CBCT , 2 (dentist > 5 years dedicated to maxillofacial radiology) , Linear measurement and tissue visibility. .. Fuglsig, 2022 12 , Cadaver specimens (12) , Posterior maxilla and mandible , Geometric accuracy of cortical bone for dental implant planning , 9.4 T (Bruker Biospec, Bruker Biospin) , Zero-Echo-Time (FOV 75 mm 3 isotropic; matrix 3663 pixels; image resolution 0.205 mm; flip angle 0.74°; TR 1.98 ms; bandwidth 2.78 kHz; projection under sampling of two; 50 averages; scan time 6 h) , 76-mm quadrature volume coil , CBCT and histology , 2 (dentist) , Cortical bone linear measurement.

Ex Vivo:

Article Title: Magnetic resonance imaging for jawbone assessment: a systematic review
Article Snippet: Deng, 2014 11 , Fresh cadaver (1) , Posterior mandible , Geometric accuracy of inferior alveolar nerve and cortical bone for maxillofacial surgery planning , 3 T (Magnetom Trio, Siemens) , Fast gradient-echo (TR/TE 2,3/3.67 ms; flip angle 10°; matrix 448 × 448 pixels; FOV 226 × 226 mm.) , Supine conventional position , CT and digital caliper , NR , Mandibular nerve canal to cortical bone linear measurement. .. Flügge, 2016 10 , Patients (2) and dry cadaver (1) , Posterior maxilla and mandible , Imaging and geometric accuracy of hard and soft tissues for maxillofacial diagnosing , 3 T (TIM Trio, Siemens) , Gradient-echo fast low flip angle shots (FLASH) (In vivo, mandible: Matrix 64 × 64 × 28 mm (115 cm3); voxel 250 × 250 × 500 μm3; TE/TR 4.2/11 ms; flip angle 15°; three averages; scanning time 3:57 min. In vivo, maxilla: isotropic resolution 350 μm; FOV 34 cm3; TR/TE 12/4.8 ms; flip angle 15°; five averages; scanning time 6:40 min. Ex vivo, mandible: isotropic resolution 200 mm3; FOV 39 × 39 × 24 mm (36.5 cm3); TE/TR 4.3/12 ms; 2 averages; flip angle 15°; scanning time 4:38 min.) , Individually fabricated (1 mm diameter copper wire, an adjustable capacitor and crossed diodes) wireless inductively/intraoral. In vivo imaging: 4-cm surface loop coil (Siemens)/close to the cheek opposite to the intraoral coil. , CBCT , 2 (dentist > 5 years dedicated to maxillofacial radiology) , Linear measurement and tissue visibility. .. Fuglsig, 2022 12 , Cadaver specimens (12) , Posterior maxilla and mandible , Geometric accuracy of cortical bone for dental implant planning , 9.4 T (Bruker Biospec, Bruker Biospin) , Zero-Echo-Time (FOV 75 mm 3 isotropic; matrix 3663 pixels; image resolution 0.205 mm; flip angle 0.74°; TR 1.98 ms; bandwidth 2.78 kHz; projection under sampling of two; 50 averages; scan time 6 h) , 76-mm quadrature volume coil , CBCT and histology , 2 (dentist) , Cortical bone linear measurement.

In Vivo Imaging:

Article Title: Magnetic resonance imaging for jawbone assessment: a systematic review
Article Snippet: Deng, 2014 11 , Fresh cadaver (1) , Posterior mandible , Geometric accuracy of inferior alveolar nerve and cortical bone for maxillofacial surgery planning , 3 T (Magnetom Trio, Siemens) , Fast gradient-echo (TR/TE 2,3/3.67 ms; flip angle 10°; matrix 448 × 448 pixels; FOV 226 × 226 mm.) , Supine conventional position , CT and digital caliper , NR , Mandibular nerve canal to cortical bone linear measurement. .. Flügge, 2016 10 , Patients (2) and dry cadaver (1) , Posterior maxilla and mandible , Imaging and geometric accuracy of hard and soft tissues for maxillofacial diagnosing , 3 T (TIM Trio, Siemens) , Gradient-echo fast low flip angle shots (FLASH) (In vivo, mandible: Matrix 64 × 64 × 28 mm (115 cm3); voxel 250 × 250 × 500 μm3; TE/TR 4.2/11 ms; flip angle 15°; three averages; scanning time 3:57 min. In vivo, maxilla: isotropic resolution 350 μm; FOV 34 cm3; TR/TE 12/4.8 ms; flip angle 15°; five averages; scanning time 6:40 min. Ex vivo, mandible: isotropic resolution 200 mm3; FOV 39 × 39 × 24 mm (36.5 cm3); TE/TR 4.3/12 ms; 2 averages; flip angle 15°; scanning time 4:38 min.) , Individually fabricated (1 mm diameter copper wire, an adjustable capacitor and crossed diodes) wireless inductively/intraoral. In vivo imaging: 4-cm surface loop coil (Siemens)/close to the cheek opposite to the intraoral coil. , CBCT , 2 (dentist > 5 years dedicated to maxillofacial radiology) , Linear measurement and tissue visibility. .. Fuglsig, 2022 12 , Cadaver specimens (12) , Posterior maxilla and mandible , Geometric accuracy of cortical bone for dental implant planning , 9.4 T (Bruker Biospec, Bruker Biospin) , Zero-Echo-Time (FOV 75 mm 3 isotropic; matrix 3663 pixels; image resolution 0.205 mm; flip angle 0.74°; TR 1.98 ms; bandwidth 2.78 kHz; projection under sampling of two; 50 averages; scan time 6 h) , 76-mm quadrature volume coil , CBCT and histology , 2 (dentist) , Cortical bone linear measurement.



Similar Products

86
Siemens Healthineers 4 cm diameter single loop small fov surface polarization coil
4 Cm Diameter Single Loop Small Fov Surface Polarization Coil, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/bilateral+breast+coil+dedicated+surface/pmc12514669-69-2-9
Average 86 stars, based on 1 article reviews
4 cm diameter single loop small fov surface polarization coil - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

96
Bruker Corporation loop surface coil
Loop Surface Coil, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/Surface+Coils/pmc12403092__pnas%2E2505294122%2Esapp-41-6-16
Average 96 stars, based on 1 article reviews
loop surface coil - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
Bruker Corporation single loop surface coil
Single Loop Surface Coil, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/Surface+Coils/pm39810939-79-21-25
Average 96 stars, based on 1 article reviews
single loop surface coil - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
PULSETEQ LTD dual tuned 31p/1h surface coil with a single 10-mm 31p loop
Dual Tuned 31p/1h Surface Coil With A Single 10 Mm 31p Loop, supplied by PULSETEQ LTD, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/31+p+surface+coil/pm40312878-47-11-13
Average 90 stars, based on 1 article reviews
dual tuned 31p/1h surface coil with a single 10-mm 31p loop - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
PULSETEQ LTD dual tuned 31 p/ 1 h surface coil with a single 10-mm 31 p loop
Dual Tuned 31 P/ 1 H Surface Coil With A Single 10 Mm 31 P Loop, supplied by PULSETEQ LTD, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/10+cm+31+p+tuned++flat+surface+coil/pmc12046211-44-14-16
Average 90 stars, based on 1 article reviews
dual tuned 31 p/ 1 h surface coil with a single 10-mm 31 p loop - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
Bruker Corporation diameter single loop surface coil
Diameter Single Loop Surface Coil, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/single+loop+surface+coil/Surface+Coils/pmc12319979-176-8-12
Average 96 stars, based on 1 article reviews
diameter single loop surface coil - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

Image Search Results