Review



silicon probe  (NeuroNexus Technologies)


Bioz Verified Symbol NeuroNexus Technologies is a verified supplier
Bioz Manufacturer Symbol NeuroNexus Technologies manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    NeuroNexus Technologies silicon probe
    Silicon Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 2516 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/pm41895264-459-1-4
    Average 97 stars, based on 2516 article reviews
    silicon probe - by Bioz Stars, 2026-11
    97/100 stars

    Images

    Related Articles

    Optogenetics:

    Article Title: Late UP-state bias in cortico-amygdalar coordination
    Article Snippet: .. 143 For acute mPFC recordings combined with optogenetic stimulation, a 32-channel silicon 144 probe with an integrated optical fiber (Buzsaki32-OA32LP-v2, NeuroNexus), coated with 145 DiO, was inserted into the mPFC (AP: 1.8 mm anterior to bregma; ML: 0.2 mm; DV: 1.5 146 mm). ..

    Silicon:

    Article Title: Late UP-state bias in cortico-amygdalar coordination
    Article Snippet: .. 143 For acute mPFC recordings combined with optogenetic stimulation, a 32-channel silicon 144 probe with an integrated optical fiber (Buzsaki32-OA32LP-v2, NeuroNexus), coated with 145 DiO, was inserted into the mPFC (AP: 1.8 mm anterior to bregma; ML: 0.2 mm; DV: 1.5 146 mm). ..

    Article Title: Navigational strategy dictates hippocampal representation of space in an everyday memory task
    Article Snippet: A craniotomy was made above the left hippocampus and an optic fiber (0.5 NA, core 400 μm SMA (FP400ERT, Thorlabs)) connected to a 625 nm fiber-coupled LED (M625F2, Thorlabs) was inserted above dorsal CA1 (AP 3.5, ML -2.6, DV -1.7). .. Next, a 32-channel 4-shank silicon probe (Buzsaki32, NeuroNexus) was inserted immediately posterior to the optic fiber, with shanks aligned with the proximo-distal axis of CA1. ..

    Article Title: Parallel retinal and circadian signalling channels organise mouse hypothalamic activity
    Article Snippet: Pupils were dilated by application of 1% atropine (Sigma Aldrich) BMC Biology and mineral oil applied to retain corneal moisture. .. Recordings used four shank silicon probes (Neuronexus), either with 32 channels (Buszaki32L, n = 6 mice) or 256 channels (4 × 64Poly2, four shanks spaced 200 μm each with two rows of 32 sites at 23 μm spacing; n = 14 mice). .. In either case, probes were coated in CM-DiI (V22888; Fisher Scientific, Loughborough, UK) for post hoc histological visualisation, prior to insertion into the brain to a depth of ~ 5.3 mm from the pial surface and an angle of 9° relative to the coronal plane.

    Article Title: A Reproducible Cortical Model of Focal Epileptiform Activity with a Multi-Biomarker Analysis Pipeline
    Article Snippet: Electrophysiological recordings were initially performed using tungsten stereotrodes during the development and optimization of the experimental model. Once the recording conditions and model parameters had been established, additional animals from each experimental group were recorded using 16-channel silicon probes (NeuroNexus Technologies, Inc., USA) to provide laminar recordings across the S1BF. .. Tungsten stereotrodes consisted of two twisted strands of 25 μm tungsten wire (Advent Research Materials, UK), whereas the 16-channel silicon probes (A1x16-5mm-50-177-A16; NeuroNexus) were connected through an Adpt-A16-OM32 adapter and comprised vertically aligned recording sites spaced 50 μm apart along a single shank, spanning a total distance of 750 μm ( ). ..

    Article Title: Representation of fear memory features in the ventral hippocampus.
    Article Snippet: .. Extracellular neuronal activity was recorded from right ventral CA1 hippocampus (-3.2mm posterior and +3.2mm lateral from the bregma and at a depth of 3.6 to 4.2 mm from brain surface) using silicon probes (NeuroNexus, 2 shank Takahashi probes with 2x32 channels and 4 shanks Buszaki probes with 8x4 channels). ..

    Tungsten:

    Article Title: A Reproducible Cortical Model of Focal Epileptiform Activity with a Multi-Biomarker Analysis Pipeline
    Article Snippet: Electrophysiological recordings were initially performed using tungsten stereotrodes during the development and optimization of the experimental model. Once the recording conditions and model parameters had been established, additional animals from each experimental group were recorded using 16-channel silicon probes (NeuroNexus Technologies, Inc., USA) to provide laminar recordings across the S1BF. .. Tungsten stereotrodes consisted of two twisted strands of 25 μm tungsten wire (Advent Research Materials, UK), whereas the 16-channel silicon probes (A1x16-5mm-50-177-A16; NeuroNexus) were connected through an Adpt-A16-OM32 adapter and comprised vertically aligned recording sites spaced 50 μm apart along a single shank, spanning a total distance of 750 μm ( ). ..

    Activity Assay:

    Article Title: Representation of fear memory features in the ventral hippocampus.
    Article Snippet: .. Extracellular neuronal activity was recorded from right ventral CA1 hippocampus (-3.2mm posterior and +3.2mm lateral from the bregma and at a depth of 3.6 to 4.2 mm from brain surface) using silicon probes (NeuroNexus, 2 shank Takahashi probes with 2x32 channels and 4 shanks Buszaki probes with 8x4 channels). ..



    Similar Products

    97
    NeuroNexus Technologies 16 channel silicon probes
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    16 Channel Silicon Probes, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/bio_rxiv__64898__2026__10__06__756259-48-18-22
    Average 97 stars, based on 1 article reviews
    16 channel silicon probes - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies silicon probes
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    Silicon Probes, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/pm42843331-1033-31-33
    Average 97 stars, based on 1 article reviews
    silicon probes - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies shank silicon probes
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    Shank Silicon Probes, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/10__1186_slash_s12915___026___02746___w-295-3-6
    Average 97 stars, based on 1 article reviews
    shank silicon probes - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies channel silicon 144 probe
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    Channel Silicon 144 Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/10__1523_slash_jneurosci__0449___26__2026-58-10-20
    Average 97 stars, based on 1 article reviews
    channel silicon 144 probe - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies 32 channel 4 shank silicon probe
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    32 Channel 4 Shank Silicon Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/pmc13691088-394-2-7
    Average 97 stars, based on 1 article reviews
    32 channel 4 shank silicon probe - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies 100 125 703 a16
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    100 125 703 A16, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/10__1063_slash_5__0335967-238-27-28
    Average 97 stars, based on 1 article reviews
    100 125 703 a16 - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies recording electrode probe
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    Recording Electrode Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/10__1016_slash_j__addicn__2026__100275-60-1-11
    Average 97 stars, based on 1 article reviews
    recording electrode probe - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    NeuroNexus Technologies configuration
    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.
    Configuration, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/silicon+microelectrode+array/Silicon+Neural+Probe+%2F+Silicon+Microelectrode+Array/bio_rxiv__64898__2026__04__16__718851-188-19-22
    Average 97 stars, based on 1 article reviews
    configuration - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    Image Search Results


    (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.

    Journal: bioRxiv

    Article Title: A Reproducible Cortical Model of Focal Epileptiform Activity with a Multi-Biomarker Analysis Pipeline

    doi: 10.64898/2026.10.06.756259

    Figure Lengend Snippet: (A) Schematic of the experimental pipeline: stereotaxic frame fixation, probe and syringe implantation, placement in a Faraday cage for signal shielding, and real-time multichannel signal acquisition using Open Ephys software. (B) Representative photograph showing the in vivo surgical site setup with stereotaxic micromanipulators positioning the injection capillary needle, recording probe, and ground wire. Design layout of the linear silicon probe array. (C) Anatomical localization of the region of interest (ROI) in the primary somatosensory cortex, barrel field (S1BF), showing histological trace verification alongside stereotaxic brain atlas coordinates.

    Article Snippet: Tungsten stereotrodes consisted of two twisted strands of 25 μm tungsten wire (Advent Research Materials, UK), whereas the 16-channel silicon probes (A1x16-5mm-50-177-A16; NeuroNexus) were connected through an Adpt-A16-OM32 adapter and comprised vertically aligned recording sites spaced 50 μm apart along a single shank, spanning a total distance of 750 μm ( ).

    Techniques: Software, In Vivo, Injection, Silicon

    (A) Representative 10-s electrophysiological traces recorded with 16-channel silicon probes in vehicle, 4-AP (15 mM), and 4-AP (15 mM) + CBZ (1 mM) groups approximately 30 min after microinjection. (B) Baseline-normalized spectrograms (0–650 Hz) from representative animals in the same experimental groups, displayed across the 16 recording sites over the complete 70-min recording period. The first 10 min correspond to baseline, and the vertical dashed line indicates the time of microinjection. Asterisks indicate the approximate time window from which the representative traces shown in panel A were extracted (∼30 min after injection). Warmer colors indicate increases in spectral power relative to baseline, whereas cooler colors indicate decreases.

    Journal: bioRxiv

    Article Title: A Reproducible Cortical Model of Focal Epileptiform Activity with a Multi-Biomarker Analysis Pipeline

    doi: 10.64898/2026.10.06.756259

    Figure Lengend Snippet: (A) Representative 10-s electrophysiological traces recorded with 16-channel silicon probes in vehicle, 4-AP (15 mM), and 4-AP (15 mM) + CBZ (1 mM) groups approximately 30 min after microinjection. (B) Baseline-normalized spectrograms (0–650 Hz) from representative animals in the same experimental groups, displayed across the 16 recording sites over the complete 70-min recording period. The first 10 min correspond to baseline, and the vertical dashed line indicates the time of microinjection. Asterisks indicate the approximate time window from which the representative traces shown in panel A were extracted (∼30 min after injection). Warmer colors indicate increases in spectral power relative to baseline, whereas cooler colors indicate decreases.

    Article Snippet: Tungsten stereotrodes consisted of two twisted strands of 25 μm tungsten wire (Advent Research Materials, UK), whereas the 16-channel silicon probes (A1x16-5mm-50-177-A16; NeuroNexus) were connected through an Adpt-A16-OM32 adapter and comprised vertically aligned recording sites spaced 50 μm apart along a single shank, spanning a total distance of 750 μm ( ).

    Techniques: Silicon, Microinjection, Injection