Review




Structured Review

SARAD GmbH rtm 1688-2 radon measuring device
Rtm 1688 2 Radon Measuring Device, supplied by SARAD GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/rtm+1688+2/pm40347625-93-8-33
Average 90 stars, based on 1 article reviews
rtm 1688-2 radon measuring device - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Radon concentration in seawater as a geochemical indicator of submarine fault activity in the Yatsushiro Sea, Japan
Article Snippet: 222 Rn concentrations were determined using a radon and thron monitor (RTM 1688, SARAD GmbH, Germany) attached to a gas–water separation bottle (Fig. ).

Article Title: The first investigation on the radiotoxicity risks associated with ingesting radium in drinking water from the Oujda Region-Morocco and some bottled mineral waters.
Article Snippet: Drinking water is essential to human life.. However, it can be polluted by various factors, including radioactive substances such as radon 222Rn and radium 226Ra.. Therefore, the determination of their concentrations is important for public health.

Article Title: Thoron, radon and microbial community as supportive indicators of seismic activity in groundwater
Article Snippet: Thoron and radon concentrations were measured simultaneously using an RTM1688-2 (SARAD, Germany) radon and thoron monitor.

Article Title: Filtering analysis of soil radon and thoron time series data
Article Snippet: Digital signal processing (DSP) is one of the most effective tools that have influenced science, engineering, and technology in the twenty-first century.. Since 1970, advancements in the expansive field of DSP have made it a crucial tool in many applications.. Many in-depth investigations on the filters and the extraction of helpful information have been conducted by researchers in a variety of scientific domains.

Activity Assay:

Article Title: Presence, distribution, and origin of radioisotopes in rock, soil, and groundwater in Central Mexico: implications of ionizing radiation for health.
Article Snippet: .. 222Rn and 220Rn activity in water were measured continuously with RAD7 electronic radon detectors (Durridge Company Inc.), coupled to a RAD-AQUA and RAD-H2O system (ICMyL and IGEO, S/N 4330) and, discretely, with a portable Alpha Spectroscopy device, SARAD_RTM1688-2 (IGEO), with factory calibration certificates that was recently put into operation. .. The collection of groundwater samples and measurement methodologies are based on the operating manuals of Durridge Inc. and SARAD.

Article Title: Presence, distribution, and origin of radioisotopes in rock, soil, and groundwater in Central Mexico: implications of ionizing radiation for health.
Article Snippet: .. 222Rn activity inside homes was detected with a portable Alpha Spectroscope (SARAD_RTM1688-2) and a RAD7 (IGEO), as described above, following the manufacturer’s guidelines and, when possible, in accordance with EPA standards. ..

Spectroscopy:

Article Title: Presence, distribution, and origin of radioisotopes in rock, soil, and groundwater in Central Mexico: implications of ionizing radiation for health.
Article Snippet: .. 222Rn and 220Rn activity in water were measured continuously with RAD7 electronic radon detectors (Durridge Company Inc.), coupled to a RAD-AQUA and RAD-H2O system (ICMyL and IGEO, S/N 4330) and, discretely, with a portable Alpha Spectroscopy device, SARAD_RTM1688-2 (IGEO), with factory calibration certificates that was recently put into operation. .. The collection of groundwater samples and measurement methodologies are based on the operating manuals of Durridge Inc. and SARAD.



Similar Products

97
Welcony rtms device
Rtms Device, supplied by Welcony, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/Rapid/pmc12882932-98-12-17
Average 97 stars, based on 1 article reviews
rtms device - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

90
Magstim Company rapid2 rtms device
Rapid2 Rtms Device, supplied by Magstim Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/magstim+200+stimulator/pm40468342-121-5-10
Average 90 stars, based on 1 article reviews
rapid2 rtms device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Magstim Company super rapid2 plus commercial rtms device
Super Rapid2 Plus Commercial Rtms Device, supplied by Magstim Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/magstim+200+stimulator/pm40108144-43-14-21
Average 90 stars, based on 1 article reviews
super rapid2 plus commercial rtms device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
SARAD GmbH rtm 1688-2 radon measuring device
Rtm 1688 2 Radon Measuring Device, supplied by SARAD GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/rtm+1688+2/pm40347625-93-8-33
Average 90 stars, based on 1 article reviews
rtm 1688-2 radon measuring device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
neuroConn GmbH ecg electrodes of the neuroconn ncg-rtms device
Ecg Electrodes Of The Neuroconn Ncg Rtms Device, supplied by neuroConn GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/ecg+electrodes+of+the+neuroconn+ncg+rtms+device/med_rxiv__2025__04__06__25325324-62-14-17
Average 90 stars, based on 1 article reviews
ecg electrodes of the neuroconn ncg-rtms device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Magstim Company super rapid 2 plus commercial rtms device
a Measured induced voltage waveform at the coil surface. b Peak magnetic flux density at different distances from the coil surface. c Single-pulse energy loss at 100% <t>power.</t> <t>Magstim</t> lost 149 J per single pulse, while <t>rTMS-tiny</t> lost only 13.4 J. d Relationship between the output frequency and the maximum available stimulus intensity. The stimulus intensity can reach 100% MSO for frequencies ranging from 1 Hz to 55 Hz. For frequencies greater than 55 Hz, the available stimulus intensity decreases. For instance, at 100 Hz, it decreases to 55% MSO. rTMS-tiny’s repetitive output capability reached the level of the Magstim Super Rapid2 Plus conventional TMS device. e Coil temperature after stimulation given a starting temperature of 25 °C. Coil temperature remained within the requirements of IEC 60601-1. f Infrared thermal imaging of the coil after 3000 pulses of 10 Hz rTMS at 95% MSO. The heat diffused from the copper coil to the surroundings, with a maximum temperature of 41.8 °C. g rTMS waveform at 100% MSO. Pulse stimulation frequency is 10 Hz. No decay of stimulation intensity between pulses. h TBS waveform at 100% MSO. Pulse stimulation frequency is 50 Hz, 3 pulses form a cluster, with a repetition frequency of clusters at 5 Hz. Less than 5% decay of stimulation intensity within each cluster, and no decay of stimulation intensity between clusters. i Battery endurance. At 70% MSO, rTMS-tiny delivered 8200 pulses of 10 Hz rTMS, and at 95% intensity, it delivered 3500 pulses.
Super Rapid 2 Plus Commercial Rtms Device, supplied by Magstim Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/rapid+2+rtms+device/pmc11923099-32-19-22
Average 90 stars, based on 1 article reviews
super rapid 2 plus commercial rtms device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Magstim Company magstim rtms device
a Measured induced voltage waveform at the coil surface. b Peak magnetic flux density at different distances from the coil surface. c Single-pulse energy loss at 100% <t>power.</t> <t>Magstim</t> lost 149 J per single pulse, while <t>rTMS-tiny</t> lost only 13.4 J. d Relationship between the output frequency and the maximum available stimulus intensity. The stimulus intensity can reach 100% MSO for frequencies ranging from 1 Hz to 55 Hz. For frequencies greater than 55 Hz, the available stimulus intensity decreases. For instance, at 100 Hz, it decreases to 55% MSO. rTMS-tiny’s repetitive output capability reached the level of the Magstim Super Rapid2 Plus conventional TMS device. e Coil temperature after stimulation given a starting temperature of 25 °C. Coil temperature remained within the requirements of IEC 60601-1. f Infrared thermal imaging of the coil after 3000 pulses of 10 Hz rTMS at 95% MSO. The heat diffused from the copper coil to the surroundings, with a maximum temperature of 41.8 °C. g rTMS waveform at 100% MSO. Pulse stimulation frequency is 10 Hz. No decay of stimulation intensity between pulses. h TBS waveform at 100% MSO. Pulse stimulation frequency is 50 Hz, 3 pulses form a cluster, with a repetition frequency of clusters at 5 Hz. Less than 5% decay of stimulation intensity within each cluster, and no decay of stimulation intensity between clusters. i Battery endurance. At 70% MSO, rTMS-tiny delivered 8200 pulses of 10 Hz rTMS, and at 95% intensity, it delivered 3500 pulses.
Magstim Rtms Device, supplied by Magstim Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/rtms+device/pm40043556-58-55-55
Average 90 stars, based on 1 article reviews
magstim rtms device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

97
Welcony human use certified rtms equipment
a Measured induced voltage waveform at the coil surface. b Peak magnetic flux density at different distances from the coil surface. c Single-pulse energy loss at 100% <t>power.</t> <t>Magstim</t> lost 149 J per single pulse, while <t>rTMS-tiny</t> lost only 13.4 J. d Relationship between the output frequency and the maximum available stimulus intensity. The stimulus intensity can reach 100% MSO for frequencies ranging from 1 Hz to 55 Hz. For frequencies greater than 55 Hz, the available stimulus intensity decreases. For instance, at 100 Hz, it decreases to 55% MSO. rTMS-tiny’s repetitive output capability reached the level of the Magstim Super Rapid2 Plus conventional TMS device. e Coil temperature after stimulation given a starting temperature of 25 °C. Coil temperature remained within the requirements of IEC 60601-1. f Infrared thermal imaging of the coil after 3000 pulses of 10 Hz rTMS at 95% MSO. The heat diffused from the copper coil to the surroundings, with a maximum temperature of 41.8 °C. g rTMS waveform at 100% MSO. Pulse stimulation frequency is 10 Hz. No decay of stimulation intensity between pulses. h TBS waveform at 100% MSO. Pulse stimulation frequency is 50 Hz, 3 pulses form a cluster, with a repetition frequency of clusters at 5 Hz. Less than 5% decay of stimulation intensity within each cluster, and no decay of stimulation intensity between clusters. i Battery endurance. At 70% MSO, rTMS-tiny delivered 8200 pulses of 10 Hz rTMS, and at 95% intensity, it delivered 3500 pulses.
Human Use Certified Rtms Equipment, supplied by Welcony, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/Rapid/bio_rxiv__2025__02__04__636500-192-30-35
Average 97 stars, based on 1 article reviews
human use certified rtms equipment - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

90
neuroConn GmbH chest electrodes from the ncg-rtms device
a Measured induced voltage waveform at the coil surface. b Peak magnetic flux density at different distances from the coil surface. c Single-pulse energy loss at 100% <t>power.</t> <t>Magstim</t> lost 149 J per single pulse, while <t>rTMS-tiny</t> lost only 13.4 J. d Relationship between the output frequency and the maximum available stimulus intensity. The stimulus intensity can reach 100% MSO for frequencies ranging from 1 Hz to 55 Hz. For frequencies greater than 55 Hz, the available stimulus intensity decreases. For instance, at 100 Hz, it decreases to 55% MSO. rTMS-tiny’s repetitive output capability reached the level of the Magstim Super Rapid2 Plus conventional TMS device. e Coil temperature after stimulation given a starting temperature of 25 °C. Coil temperature remained within the requirements of IEC 60601-1. f Infrared thermal imaging of the coil after 3000 pulses of 10 Hz rTMS at 95% MSO. The heat diffused from the copper coil to the surroundings, with a maximum temperature of 41.8 °C. g rTMS waveform at 100% MSO. Pulse stimulation frequency is 10 Hz. No decay of stimulation intensity between pulses. h TBS waveform at 100% MSO. Pulse stimulation frequency is 50 Hz, 3 pulses form a cluster, with a repetition frequency of clusters at 5 Hz. Less than 5% decay of stimulation intensity within each cluster, and no decay of stimulation intensity between clusters. i Battery endurance. At 70% MSO, rTMS-tiny delivered 8200 pulses of 10 Hz rTMS, and at 95% intensity, it delivered 3500 pulses.
Chest Electrodes From The Ncg Rtms Device, supplied by neuroConn GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/rtms+device/chest+electrodes+from+the+ncg+rtms+device/med_rxiv__2025__01__09__25320274-79-14-16
Average 90 stars, based on 1 article reviews
chest electrodes from the ncg-rtms device - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


a Measured induced voltage waveform at the coil surface. b Peak magnetic flux density at different distances from the coil surface. c Single-pulse energy loss at 100% power. Magstim lost 149 J per single pulse, while rTMS-tiny lost only 13.4 J. d Relationship between the output frequency and the maximum available stimulus intensity. The stimulus intensity can reach 100% MSO for frequencies ranging from 1 Hz to 55 Hz. For frequencies greater than 55 Hz, the available stimulus intensity decreases. For instance, at 100 Hz, it decreases to 55% MSO. rTMS-tiny’s repetitive output capability reached the level of the Magstim Super Rapid2 Plus conventional TMS device. e Coil temperature after stimulation given a starting temperature of 25 °C. Coil temperature remained within the requirements of IEC 60601-1. f Infrared thermal imaging of the coil after 3000 pulses of 10 Hz rTMS at 95% MSO. The heat diffused from the copper coil to the surroundings, with a maximum temperature of 41.8 °C. g rTMS waveform at 100% MSO. Pulse stimulation frequency is 10 Hz. No decay of stimulation intensity between pulses. h TBS waveform at 100% MSO. Pulse stimulation frequency is 50 Hz, 3 pulses form a cluster, with a repetition frequency of clusters at 5 Hz. Less than 5% decay of stimulation intensity within each cluster, and no decay of stimulation intensity between clusters. i Battery endurance. At 70% MSO, rTMS-tiny delivered 8200 pulses of 10 Hz rTMS, and at 95% intensity, it delivered 3500 pulses.

Journal: Nature Communications

Article Title: A wearable repetitive transcranial magnetic stimulation device

doi: 10.1038/s41467-025-58095-9

Figure Lengend Snippet: a Measured induced voltage waveform at the coil surface. b Peak magnetic flux density at different distances from the coil surface. c Single-pulse energy loss at 100% power. Magstim lost 149 J per single pulse, while rTMS-tiny lost only 13.4 J. d Relationship between the output frequency and the maximum available stimulus intensity. The stimulus intensity can reach 100% MSO for frequencies ranging from 1 Hz to 55 Hz. For frequencies greater than 55 Hz, the available stimulus intensity decreases. For instance, at 100 Hz, it decreases to 55% MSO. rTMS-tiny’s repetitive output capability reached the level of the Magstim Super Rapid2 Plus conventional TMS device. e Coil temperature after stimulation given a starting temperature of 25 °C. Coil temperature remained within the requirements of IEC 60601-1. f Infrared thermal imaging of the coil after 3000 pulses of 10 Hz rTMS at 95% MSO. The heat diffused from the copper coil to the surroundings, with a maximum temperature of 41.8 °C. g rTMS waveform at 100% MSO. Pulse stimulation frequency is 10 Hz. No decay of stimulation intensity between pulses. h TBS waveform at 100% MSO. Pulse stimulation frequency is 50 Hz, 3 pulses form a cluster, with a repetition frequency of clusters at 5 Hz. Less than 5% decay of stimulation intensity within each cluster, and no decay of stimulation intensity between clusters. i Battery endurance. At 70% MSO, rTMS-tiny delivered 8200 pulses of 10 Hz rTMS, and at 95% intensity, it delivered 3500 pulses.

Article Snippet: Remarkably, rTMS-tiny is able to achieve repetition frequency and stimulus intensity that match the Super Rapid 2 Plus commercial rTMS device from Magstim.

Techniques: Imaging, Battery

a RMT test results for both hands and both legs. The smaller dots denote each participant’s RMT value. The larger dots denote the mean RMT values ( n = 15). The mixed-effects analysis was used to analyse RMT values, and p values were 0.003, 0.005, 0.073, and 0.621, respectively. b MEP amplitudes for both hands APB muscles in 15 subjects under output power ranging from 50% to 100% MSO. Comparing the MEP amplitudes induced by Magstim and rTMS-tiny at 80%, 90%, and 100% MSO, showed that the maximum stimulus intensity of rTMS-tiny is about 89% of Magstim for the right-hand APB muscle and 90% for the left-hand APB muscle. c MEP amplitudes for both legs TA muscles in 15 subjects under output power ranging from 50% to 100% MSO. Comparing the MEP amplitudes induced by Magstim and rTMS-tiny at 80%, 90%, and 100% MSO showed that the maximum stimulus intensity of rTMS-tiny is about 90% of Magstim for both legs TA muscles. Error bars denote standard errors of the means. A total of 10 technical replicates were used to calculate the MEP amplitudes in ( a – c ). We did not establish the control group using a sham TMS coil because it is clear that no MEP or RMT can be elicited by the sham coil.

Journal: Nature Communications

Article Title: A wearable repetitive transcranial magnetic stimulation device

doi: 10.1038/s41467-025-58095-9

Figure Lengend Snippet: a RMT test results for both hands and both legs. The smaller dots denote each participant’s RMT value. The larger dots denote the mean RMT values ( n = 15). The mixed-effects analysis was used to analyse RMT values, and p values were 0.003, 0.005, 0.073, and 0.621, respectively. b MEP amplitudes for both hands APB muscles in 15 subjects under output power ranging from 50% to 100% MSO. Comparing the MEP amplitudes induced by Magstim and rTMS-tiny at 80%, 90%, and 100% MSO, showed that the maximum stimulus intensity of rTMS-tiny is about 89% of Magstim for the right-hand APB muscle and 90% for the left-hand APB muscle. c MEP amplitudes for both legs TA muscles in 15 subjects under output power ranging from 50% to 100% MSO. Comparing the MEP amplitudes induced by Magstim and rTMS-tiny at 80%, 90%, and 100% MSO showed that the maximum stimulus intensity of rTMS-tiny is about 90% of Magstim for both legs TA muscles. Error bars denote standard errors of the means. A total of 10 technical replicates were used to calculate the MEP amplitudes in ( a – c ). We did not establish the control group using a sham TMS coil because it is clear that no MEP or RMT can be elicited by the sham coil.

Article Snippet: Remarkably, rTMS-tiny is able to achieve repetition frequency and stimulus intensity that match the Super Rapid 2 Plus commercial rTMS device from Magstim.

Techniques: Muscles, Control