Review




Structured Review

Tosoh Corporation ri differential refractometer data processing
Ri Differential Refractometer Data Processing, supplied by Tosoh Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ri+differential+refractometer+data+processing/data+differential+processing+refractometer+ri/us12649822-122-1-13
Average 86 stars, based on 1 article reviews
ri differential refractometer data processing - by Bioz Stars, 2026-09
86/100 stars

Images

Related Articles

Gel Permeation Chromatography:

Article Title: Adhesive, laminate, and packaging material
Article Snippet: .. Measuring device: HLC-8320GPC manufactured by Tosoh Corporation Column: TSKgel 4000HXL, TSKgel 3000HXL, TSKgel 2000HXL, and TSKgel 1000HXL manufactured by Tosoh Corporation Detector: RI (differential refractometer) Data processing: Multistation GPC-8020 model II manufactured by Tosoh Corporation Measurement conditions: column temperature 40° C. solvent Tetrahydrofuran flow rate 0.35 ml/min Standard: Monodisperse polystyrene Sample: A sample obtained by filtering a 0.2% by mass tetrahydrofuran solution in terms of resin solid content with a microfilter (100 μl) The hydroxyl value of the polyester polyol (A1) is preferably in a range of 1 to 150 mgKOH/g, and more preferably 3 mgKOH/g or more and 100 mgKOH/g or less. ..

Article Title: Branched degradable polyethylene glycol binder
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) standard polymer: Using polyethylene glycols with molecular weight of 8,000, 20,000, 50,000 and 100,000 as standard polymers, the molecular weight was measured by GPC analysis. detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

Article Title: Degradable multi-arm polyethylene glycol derivative
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Solvent:

Article Title: Adhesive, laminate, and packaging material
Article Snippet: .. Measuring device: HLC-8320GPC manufactured by Tosoh Corporation Column: TSKgel 4000HXL, TSKgel 3000HXL, TSKgel 2000HXL, and TSKgel 1000HXL manufactured by Tosoh Corporation Detector: RI (differential refractometer) Data processing: Multistation GPC-8020 model II manufactured by Tosoh Corporation Measurement conditions: column temperature 40° C. solvent Tetrahydrofuran flow rate 0.35 ml/min Standard: Monodisperse polystyrene Sample: A sample obtained by filtering a 0.2% by mass tetrahydrofuran solution in terms of resin solid content with a microfilter (100 μl) The hydroxyl value of the polyester polyol (A1) is preferably in a range of 1 to 150 mgKOH/g, and more preferably 3 mgKOH/g or more and 100 mgKOH/g or less. ..

Molecular Weight:

Article Title: Branched degradable polyethylene glycol binder
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) standard polymer: Using polyethylene glycols with molecular weight of 8,000, 20,000, 50,000 and 100,000 as standard polymers, the molecular weight was measured by GPC analysis. detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

Article Title: Degradable multi-arm polyethylene glycol derivative
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Polymer:

Article Title: Branched degradable polyethylene glycol binder
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) standard polymer: Using polyethylene glycols with molecular weight of 8,000, 20,000, 50,000 and 100,000 as standard polymers, the molecular weight was measured by GPC analysis. detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

High Performance Liquid Chromatography:

Article Title: Branched degradable polyethylene glycol binder
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) standard polymer: Using polyethylene glycols with molecular weight of 8,000, 20,000, 50,000 and 100,000 as standard polymers, the molecular weight was measured by GPC analysis. detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Article Title: Degradable multi-arm polyethylene glycol derivative
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Injection:

Article Title: Branched degradable polyethylene glycol binder
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) standard polymer: Using polyethylene glycols with molecular weight of 8,000, 20,000, 50,000 and 100,000 as standard polymers, the molecular weight was measured by GPC analysis. detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

Article Title: Degradable multi-arm polyethylene glycol derivative
Article Snippet: .. GPC Analysis (Molecular Weight Measurement) detector: differential refractometer column: ultrahydrogel 500 and ultrahydrogel 250 (manufactured by WATERS) mobile phase: 100 mM Acetate buffer+0.02% NaN3 (pH 5.2) flow rate: 0.5 mL/min sample volume: 5 mg/mL, 20 μL column temperature: 30° C. HPLC Analysis (Amine Purity Measurement) detector: differential refractometer column: TSKgel SP-5PW (manufactured by Tosoh Corporation) mobile phase: 1 mM Sodium phosphate buffer (pH 6.5) flow rate: 0.5 mL/min injection volume: 5 mg/mL, 20 μL column temperature: 40° C. ..

Refractive Index:

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

Concentration Assay:

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

Software:

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

Produced:

Article Title: Curable composition, urethane resin, and heat dissipation member
Article Snippet: .. Device: HLC-8120 (Tosoh Corporation) Column: TSKgel α-6000, G3000 PWXL (Tosoh Corporation) Detector: refractive index (RI) Eluent: 0.5% sodium acetate in water/methanol (volume ratio: 70/30) Eluent flow rate: 1.0 ml/min Column temperature: 40° C. Sample concentration: 0.25% by weight Amount to be injected: 200 μl Standard substance: TSK standard polyethylene oxide (Tosoh Corporation) Data processing software: GPC-8020 model II (Tosoh Corporation) The polyalkylene glycol (A1) having a chemical formula weight or average molecular weight of 1000 or less can be produced by known methods. ..

GPC Assay:

Article Title: Production and some properties of a dextrin with a narrow size distribution by the cyclization reaction of branching enzyme
Article Snippet: Branching enzyme (BE, EC 2.4.1.18) catalyzes the cyclization of amylose and amylopectin (Takata et al., J.. Bacterial., 178, 1600-1606, 1996; Takata et al., Carbohydr.. Res., 295, 91-101, 1996).



Similar Products

86
Tosoh Corporation ri differential refractometer data processing
Ri Differential Refractometer Data Processing, supplied by Tosoh Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ri+differential+refractometer+data+processing/data+differential+processing+refractometer+ri/us12649822-122-1-13
Average 86 stars, based on 1 article reviews
ri differential refractometer data processing - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

Image Search Results