Review



ac-asp-d-gla-leu-ile-b-cyclohexyl-ala-cyc-oh n-1725.0001  (Bachem)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Bachem ac-asp-d-gla-leu-ile-b-cyclohexyl-ala-cyc-oh n-1725.0001
    Before cleavage, GFP was found in the plasma membrane (ring shape, before cleavage). Cleavage of the type I MBR by <t>HCV</t> <t>NS3</t> protease resulted in the translocation of GFP to the cytosol (dispersed image, after cleavage).
    Ac Asp D Gla Leu Ile B Cyclohexyl Ala Cyc Oh N 1725.0001, supplied by Bachem, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/reference+compound+1++n+1725/pmc03605327-49-5-10
    Average 90 stars, based on 1 article reviews
    ac-asp-d-gla-leu-ile-b-cyclohexyl-ala-cyc-oh n-1725.0001 - by Bioz Stars, 2026-08
    90/100 stars

    Images

    1) Product Images from "In-Cell Protease Assay Systems Based on Trans-Localizing Molecular Beacon Proteins Using HCV Protease as a Model System"

    Article Title: In-Cell Protease Assay Systems Based on Trans-Localizing Molecular Beacon Proteins Using HCV Protease as a Model System

    Journal: PLoS ONE

    doi: 10.1371/journal.pone.0059710

    Before cleavage, GFP was found in the plasma membrane (ring shape, before cleavage). Cleavage of the type I MBR by HCV NS3 protease resulted in the translocation of GFP to the cytosol (dispersed image, after cleavage).
    Figure Legend Snippet: Before cleavage, GFP was found in the plasma membrane (ring shape, before cleavage). Cleavage of the type I MBR by HCV NS3 protease resulted in the translocation of GFP to the cytosol (dispersed image, after cleavage).

    Techniques Used: Clinical Proteomics, Membrane, Translocation Assay

    Type II MBRs were constructed to contain a mitochondrial targeting sequence, MSRA as a masked translocation signal. The masking protein used was GAPDH or GFP for mono- or dual-color type II MBRs, respectively. A . Cleavage of mono-color type II MBR by HCV NS3 protease activates the mitochondrial translocation signal of MSRA, resulting in translocation of GFP from the cytosol (before cleavage) to the mitochondria (after cleavage). B . Cleavage of dual-color type II MBR which contains both GFP and RFP, results in translocation of the RFP from the cytosol (before cleavage) to mitochondria while GFP remains in the cytosol (after cleavage) following cleavage. GFP; green fluorescent protein, RFP; red fluorescent protein.
    Figure Legend Snippet: Type II MBRs were constructed to contain a mitochondrial targeting sequence, MSRA as a masked translocation signal. The masking protein used was GAPDH or GFP for mono- or dual-color type II MBRs, respectively. A . Cleavage of mono-color type II MBR by HCV NS3 protease activates the mitochondrial translocation signal of MSRA, resulting in translocation of GFP from the cytosol (before cleavage) to the mitochondria (after cleavage). B . Cleavage of dual-color type II MBR which contains both GFP and RFP, results in translocation of the RFP from the cytosol (before cleavage) to mitochondria while GFP remains in the cytosol (after cleavage) following cleavage. GFP; green fluorescent protein, RFP; red fluorescent protein.

    Techniques Used: Construct, Sequencing, Translocation Assay

    The cleavage of type I MBR ( A ) and type II MBR ( B ) by HCV NS3 protease was monitored in the presence of a known peptide derivative inhibitor, Ac-Asp-D-Gla-Leu-Ile-β-cyclohexyl-Ala-Cyc-OH. Both type I and type II MBRs exhibited significant dose-response at nanomolar concentrations.
    Figure Legend Snippet: The cleavage of type I MBR ( A ) and type II MBR ( B ) by HCV NS3 protease was monitored in the presence of a known peptide derivative inhibitor, Ac-Asp-D-Gla-Leu-Ile-β-cyclohexyl-Ala-Cyc-OH. Both type I and type II MBRs exhibited significant dose-response at nanomolar concentrations.

    Techniques Used:

    An HCV NS3 protease inhibitory RNA aptamer was prepared and tested. Cells co-transfected with vectors encoding type I MBR and HCV NS3 protease were and treated with the RNA aptamer. The inhibition ratio was determined from the number of cells exhibiting a dispersed pattern relative to the total number of cells examined.
    Figure Legend Snippet: An HCV NS3 protease inhibitory RNA aptamer was prepared and tested. Cells co-transfected with vectors encoding type I MBR and HCV NS3 protease were and treated with the RNA aptamer. The inhibition ratio was determined from the number of cells exhibiting a dispersed pattern relative to the total number of cells examined.

    Techniques Used: Transfection, Inhibition



    Similar Products

    94
    MedChemExpress reference compounds
    Reference Compounds, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/Furosemide/pm42533546-123-17-23
    Average 94 stars, based on 1 article reviews
    reference compounds - by Bioz Stars, 2026-08
    94/100 stars
      Buy from Supplier

    94
    TargetMol antiviral reference compounds brincidofovir
    Antiviral Reference Compounds Brincidofovir, supplied by TargetMol, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/Brincidofovir/pm41790953-53-0-6
    Average 94 stars, based on 1 article reviews
    antiviral reference compounds brincidofovir - by Bioz Stars, 2026-08
    94/100 stars
      Buy from Supplier

    94
    Thermo Fisher reference compounds fluconazole
    Reference Compounds Fluconazole, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/Fluconazole%2C+99%25/pm41772813-246-7-10
    Average 94 stars, based on 1 article reviews
    reference compounds fluconazole - by Bioz Stars, 2026-08
    94/100 stars
      Buy from Supplier

    95
    MedChemExpress reference compound psma
    Reference Compound Psma, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/Vipivotide+tetraxetan/pm42407347-49-1-7
    Average 95 stars, based on 1 article reviews
    reference compound psma - by Bioz Stars, 2026-08
    95/100 stars
      Buy from Supplier

    86
    Merck & Co reference compound
    Reference Compound, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/compound+reference/pmc13063356-79-1-16
    Average 86 stars, based on 1 article reviews
    reference compound - by Bioz Stars, 2026-08
    86/100 stars
      Buy from Supplier

    86
    Macklin Inc pat reference compound
    Pat Reference Compound, supplied by Macklin Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/compound+pat+reference/pm41950845-54-1-12
    Average 86 stars, based on 1 article reviews
    pat reference compound - by Bioz Stars, 2026-08
    86/100 stars
      Buy from Supplier

    86
    Merck & Co reference compounds
    Reference Compounds, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/compounds+reference/pmc12870835-187-3-12
    Average 86 stars, based on 1 article reviews
    reference compounds - by Bioz Stars, 2026-08
    86/100 stars
      Buy from Supplier

    94
    LGC Standards certified reference materials
    Certified Reference Materials, supplied by LGC Standards, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reference+compound/16%2E4%25+Arom%2E+compounds%2C+ASTM+D1319/pmc12954034-113-5-9
    Average 94 stars, based on 1 article reviews
    certified reference materials - by Bioz Stars, 2026-08
    94/100 stars
      Buy from Supplier

    Image Search Results