polybench physiological software (Applied Biosignals GmbH)
90
Structured Review
Applied Biosignals GmbH
polybench physiological software
Polybench Physiological Software, supplied by Applied Biosignals GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polybench+software/polybench+physiological+software/pmc06362425-68-36-39
Average 90 stars, based on 1 article reviews
Polybench Physiological Software, supplied by Applied Biosignals GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polybench+software/polybench+physiological+software/pmc06362425-68-36-39
Average 90 stars, based on 1 article reviews
polybench physiological software - by Bioz Stars,
2026-10
90/100 stars
Images
Related Articles
Software:Article Title: Comparison of Two Respiratory Support Strategies for Stabilization of Very Preterm Infants at Birth: A Matched-Pairs Analysis Article Snippet: FiO 2 was measured using a portable oxygen analyzer AX300-I (Teledyne Analytical Instruments, CA, USA), and the airway pressures were registered by a variable orifice flow sensor (Avea Varflex Flow Transducer, Carefusion, Yorba Linda, CA, USA) connected to the facemask, measuring the flow in and out the infant. .. The signals were digitized at 200 Hz using the NewLifeBox-R physiological recording system (Advanced Life Diagnostics, Weener, Germany) and all signals were recorded by the NewLifeBox Neo-RSD computer system (Advanced Life Diagnostics, Weener, Germany) supported by Article Title: The effect of imposed resistance in neonatal resuscitators on pressure stability and peak flows: a bench test. Article Snippet: BACKGROUND: The importance of neonatal resuscitator resistance is currently unknown.. In this study we investigated peak flows and pressure stability resulting from differences in imposed resistance during positive pressure ventilation(PPV) and simulated spontaneous breathing (SSB) between the r-PAP, low-resistance resuscitator, and NeopuffTM, high-resistance resuscitator.. METHODS: In a bench test, 20 inflations during PPV and 20 breaths during SSB were analysed on breath-by-breath basis to determine peak flow and pressure stability using the NeopuffTM with bias gas flow of 8, 12 or 15 L/min and the r-PAP with total gas flow of 15 L/min. Article Title: Effect of initial and subsequent mask applications on breathing and heart rate in preterm infants at birth. Article Snippet: To cite: Kuypers KLAM, Hopman A, Cramer SJE, et al. Arch Dis Child Fetal Neonatal Ed 2023;108:F594–F598.. Division of Neonatology, Department of Paediatrics, WillemAlexander Children’s Hospital, Leiden University Medical Centre, Leiden, The Netherlands The Ritchie Centre, The Hudson Institute for Medical Research, Clayton, Victoria, Australia Obstetrics and Gynaecology, Monash University, Melbourne, Victoria, Australia Article Title: Physiological-based cord clamping in preterm infants using a new purpose-built resuscitation table: a feasibility study Article Snippet: .. The signals were digitised at 200 Hz using the NewLifeBox –R physiological recording system (Advanced Life Diagnostics) supported by Article Title: The effect of histological and subclinical chorioamnionitis and funisitis on breathing effort in premature infants at birth: a retrospective cohort study Article Snippet: .. Collected RFM data consisted of physiological measurements in the first 5 min after birth using a Masimo SET pulse oximeter probe (Masimo Radical, Masimo Corporation, Irvine, California, USA), a portable oxygen analyser (AX300-I Teledyne Analytical Instruments, CA, USA) and a variable orifice flow sensor (Avea Varflex Flow Transducer, Carefusion, Yorba Linda, CA, USA) recorded digitally using the Article Title: The Effect of Initial High vs. Low FiO 2 on Breathing Effort in Preterm Infants at Birth: A Randomized Controlled Trial Article Snippet: The FiO 2 was measured using a portable oxygen analyzer AX300-I (Teledyne Analytical Instruments, CA, USA). .. The signals were digitized at 200 Hz using the NewLifeBox-R physiological recording system (Advanced Life Diagnostics, Weener, Germany) and all signals were recorded by the NewLifeBox Neo-RSD computer system (Advanced Life Diagnostics, Weener, Germany) supported by Article Title: High vs. Low Initial Oxygen to Improve the Breathing Effort of Preterm Infants at Birth: Study Protocol for a Randomized Controlled Trial Article Snippet: The FiO 2 is measured using a portable oxygen analyzer AX300-I (Teledyne Analytical Instruments, CA, USA), and the airway pressures are registered by a variable orifice flow sensor (Avea Varflex Flow Transducer, Carefusion, Yorba Linda, CA, USA) connected to the facemask measuring the flow in and out the infant. .. The signals are digitized at 200 Hz using the NewLifeBox-R physiological recording system (Advanced Life Diagnostics, Weener, Germany) and all signals are recorded by the NewLifeBox Neo-RSD computer system (Advanced Life Diagnostics, Weener, Germany) supported by Article Title: Paediatric exhaled CO 2 detector causes leaks. Article Snippet: .. NewLifeBox- R physiological recording system and recorded by the NewLifeBox Neo- RSD computer system (Advanced Life Diagnostics, Weener, Germany) supported by |