Review



multiclamp 700 b amplifier  (Danaher Inc)


Bioz Verified Symbol Danaher Inc is a verified supplier
Bioz Manufacturer Symbol Danaher Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Danaher Inc multiclamp 700 b amplifier
    Multiclamp 700 B Amplifier, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 13996 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/MultiClamp+700B+current+%26+patch+clamp+amplifier/pmc12407562-156-19-23
    Average 99 stars, based on 13996 article reviews
    multiclamp 700 b amplifier - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    Patch Clamp:

    Article Title: Bipolar cell networks underlying steady-state intensity encoding in intrinsically photosensitive retinal ganglion cells
    Article Snippet: .. Whole-cell patch-clamp for current recordings in flat-mount retinas was performed as described, using a Multiclamp 700B amplifier, Digidata 1550 digitizer, and pClamp 10.5 data acquisition software (Molecular Devices; 10 kHz sampling). .. Pipettes pulled from thick-walled borosilicate capillaries (P-97; Sutter Instruments) had tip resistances of 5–6 MΩ when filled (in mM, 120 Cs-methanesulfonate, 5 NaCl, 4 CsCl, 2 EGTA, 10 HEPES, 4 ATP-mg, 7 Phosphocreatine-tris, and 0.3 GTP-tris, pH 7.3, 270–280 mOsm).

    Software:

    Article Title: Bipolar cell networks underlying steady-state intensity encoding in intrinsically photosensitive retinal ganglion cells
    Article Snippet: .. Whole-cell patch-clamp for current recordings in flat-mount retinas was performed as described, using a Multiclamp 700B amplifier, Digidata 1550 digitizer, and pClamp 10.5 data acquisition software (Molecular Devices; 10 kHz sampling). .. Pipettes pulled from thick-walled borosilicate capillaries (P-97; Sutter Instruments) had tip resistances of 5–6 MΩ when filled (in mM, 120 Cs-methanesulfonate, 5 NaCl, 4 CsCl, 2 EGTA, 10 HEPES, 4 ATP-mg, 7 Phosphocreatine-tris, and 0.3 GTP-tris, pH 7.3, 270–280 mOsm).

    Article Title: The Cullin3–Ring E3 ubiquitin ligase complex and USP14 regulate spastin-mediated microtubule severing and promotion of neurite outgrowth
    Article Snippet: .. Recordings were performed at room temperature in voltage clamp mode, at a holding potential of -70 mV, using a Multiclamp 700 B amplifier (Molecular Devices, Sunnyvale, CA, USA) and Clampex 10.5 software (Axon Instruments, Union City, CA, USA). .. The series resistance was below 30 MΩ, and data were acquired at 10 kHz and filtered at 1 kHz. mEPSCs were analyzed using MiniAnalysis software (Synaptosoft, Decatur, GA, USA).

    Sampling:

    Article Title: Bipolar cell networks underlying steady-state intensity encoding in intrinsically photosensitive retinal ganglion cells
    Article Snippet: .. Whole-cell patch-clamp for current recordings in flat-mount retinas was performed as described, using a Multiclamp 700B amplifier, Digidata 1550 digitizer, and pClamp 10.5 data acquisition software (Molecular Devices; 10 kHz sampling). .. Pipettes pulled from thick-walled borosilicate capillaries (P-97; Sutter Instruments) had tip resistances of 5–6 MΩ when filled (in mM, 120 Cs-methanesulfonate, 5 NaCl, 4 CsCl, 2 EGTA, 10 HEPES, 4 ATP-mg, 7 Phosphocreatine-tris, and 0.3 GTP-tris, pH 7.3, 270–280 mOsm).

    other:

    Article Title: Cingulate thrombospondin 4 protects against neuropathic pain and comorbid anxiodepression via interaction with EAAT2.
    Article Snippet: CTATGTCGTCGTCGCAGGCATC(R) Sangon N/A Bacterial and virus strains rAAV2/9-hSyn-mThbs4-3×FLAG-P2A-mCherry-WPREhGH polyA Braincase N/A rAAV2/9-hSyn-mThbs4-2A-EGFP-WPREs BrainVTA N/A rAAV2/9-hSyn-EGFP-WPREs Braincase N/A rAAV2/9-hSyn-mCherry-WPREs Braincase N/A rAAV2/9-CaMKIIα-GCaMP6s-WPREs-pA Braincase N/A rAAV-hSyn-iGluSnFR3.v857.GPI Braincase N/A rAAV2/9-CMV-mThbs4-3×FLAG-P2A Braincase N/A rAAV2/9-CMV-3×FLAG-P2A Braincase N/A Experimental models: Organisms/strains Mouse: C57BL/6J Fourth Military Medical University RRID: IMSR_JAX:000664 Experimental models: Cell lines HEK 293FT Invitrogen Cat# R70007; RRID: CVCL_6911 Critical commercial assays BCA protein assay kit Thermo Scientific Cat# 23225 Plasma membrane protein isolation and cell fractionation Invent Cat# SM-05 Glutamic acid colorimetric assay kit Elabscience Cat# E-BC-K903-M Deposited data RNA-Seq data Li et al.20 SRP323752 Software and algorithms SMART v.3.0 Panlab http://smart.embl.de/ Imaris software Bitplane http://www.bitplane.com/imaris/imaris Statistical Program for Social Sciences 21.0 SPSS http://www-01.ibm.com/software/ uk/analytics/spss/ Prism GraphPad https://www.graphpad.com/ Others Elevated mesh-bottom platform Danmic Global N/A Thermal sensitivity device IITC Life science RRID:SCR_012152 Applied Biosystems Real-time PCR system Thermofisher RRID:SCR_025855 FV3000 Confocal microscope Olympus RRID:SCR_017015 Stereotactic frame RWD Life Science Inc N/A 10 μL microsyringe Gaoge N/A Microsyringe pump Kd Scientific N/A 1200s Vibratome Leica RRID:SCR_018453 Dichroic mirror fiber photometry recording Thorlabs N/A Optical commutator for fiber photometry recording Doris Lenses N/A Low-pass filter for fiber photometry recording ThinkerTech N/A S-4800 Scanning electron microscope Hitachi RRID:SCR_020018 Axon700B amplifier Molecular Devices Corporation N/A 20 Cell Reports 45, 118112, October 27, 2026

    Activation Assay:

    Article Title: Prelimbic cortex to zona incerta pathway mediates recognition memory recovery delay through down-regulating astrocytic GAT-3
    Article Snippet: ZI sagittal slices (350 μm thickness) were cut with a vibrating slicer (Leica, VT1200S, Germany) under a continuous supply of oxygen mixture, and the ZI brain slices were incubated at 32°C in ACSF containing (in mM) 126 NaCl, 2.5 KCl, 1.25 NaH 2 PO 4 , 1.3 MgCl 2 , 2 CaCl 2 , 26 NaHCO 3 , and 10 glucose, pH (7.3, 300-305 mOsm / kg) at room temperature and incubated for 1 h. All reagents were purchased from Sigma Aldrich, USA. .. For chemogenetic activation or inhibition of ZI neurons, 10 mM CNO was applied during activity potential recording. membrane potentials were acquired with a MultiClamp 700B amplifier (Molecular Devices), filtered at 1 kHz, and sampled at 20 kHz with a Digidata 1440A interface and Clampex 10.2 (Molecular Devices). ..

    Inhibition:

    Article Title: Prelimbic cortex to zona incerta pathway mediates recognition memory recovery delay through down-regulating astrocytic GAT-3
    Article Snippet: ZI sagittal slices (350 μm thickness) were cut with a vibrating slicer (Leica, VT1200S, Germany) under a continuous supply of oxygen mixture, and the ZI brain slices were incubated at 32°C in ACSF containing (in mM) 126 NaCl, 2.5 KCl, 1.25 NaH 2 PO 4 , 1.3 MgCl 2 , 2 CaCl 2 , 26 NaHCO 3 , and 10 glucose, pH (7.3, 300-305 mOsm / kg) at room temperature and incubated for 1 h. All reagents were purchased from Sigma Aldrich, USA. .. For chemogenetic activation or inhibition of ZI neurons, 10 mM CNO was applied during activity potential recording. membrane potentials were acquired with a MultiClamp 700B amplifier (Molecular Devices), filtered at 1 kHz, and sampled at 20 kHz with a Digidata 1440A interface and Clampex 10.2 (Molecular Devices). ..

    Activity Assay:

    Article Title: Prelimbic cortex to zona incerta pathway mediates recognition memory recovery delay through down-regulating astrocytic GAT-3
    Article Snippet: ZI sagittal slices (350 μm thickness) were cut with a vibrating slicer (Leica, VT1200S, Germany) under a continuous supply of oxygen mixture, and the ZI brain slices were incubated at 32°C in ACSF containing (in mM) 126 NaCl, 2.5 KCl, 1.25 NaH 2 PO 4 , 1.3 MgCl 2 , 2 CaCl 2 , 26 NaHCO 3 , and 10 glucose, pH (7.3, 300-305 mOsm / kg) at room temperature and incubated for 1 h. All reagents were purchased from Sigma Aldrich, USA. .. For chemogenetic activation or inhibition of ZI neurons, 10 mM CNO was applied during activity potential recording. membrane potentials were acquired with a MultiClamp 700B amplifier (Molecular Devices), filtered at 1 kHz, and sampled at 20 kHz with a Digidata 1440A interface and Clampex 10.2 (Molecular Devices). ..

    Membrane:

    Article Title: Prelimbic cortex to zona incerta pathway mediates recognition memory recovery delay through down-regulating astrocytic GAT-3
    Article Snippet: ZI sagittal slices (350 μm thickness) were cut with a vibrating slicer (Leica, VT1200S, Germany) under a continuous supply of oxygen mixture, and the ZI brain slices were incubated at 32°C in ACSF containing (in mM) 126 NaCl, 2.5 KCl, 1.25 NaH 2 PO 4 , 1.3 MgCl 2 , 2 CaCl 2 , 26 NaHCO 3 , and 10 glucose, pH (7.3, 300-305 mOsm / kg) at room temperature and incubated for 1 h. All reagents were purchased from Sigma Aldrich, USA. .. For chemogenetic activation or inhibition of ZI neurons, 10 mM CNO was applied during activity potential recording. membrane potentials were acquired with a MultiClamp 700B amplifier (Molecular Devices), filtered at 1 kHz, and sampled at 20 kHz with a Digidata 1440A interface and Clampex 10.2 (Molecular Devices). ..



    Similar Products

    97
    Danaher Inc operational amplifier axopatch 200b
    Operational Amplifier Axopatch 200b, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/Axopatch+200B-2+capacitor+feedback+patch+clamp+amplifier/pm42919372-78-15-23
    Average 97 stars, based on 1 article reviews
    operational amplifier axopatch 200b - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    93
    Sutter Instrument Company dpatch integrated amplifier data acquisition system
    Dpatch Integrated Amplifier Data Acquisition System, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/dPATCH+Low-noise+Ultra-fast+Digital+Patch+Clamp+Amplifier+System/pmc13694097-149-46-44
    Average 93 stars, based on 1 article reviews
    dpatch integrated amplifier data acquisition system - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    97
    Danaher Inc axopatch 200b amplifier
    Axopatch 200b Amplifier, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/Axopatch+200B-2+capacitor+feedback+patch+clamp+amplifier/pmc13690978-306-21-24
    Average 97 stars, based on 1 article reviews
    axopatch 200b amplifier - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    96
    Danaher Inc axon amplifier
    Axon Amplifier, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/Axon+Instruments+Patch-Clamp+Amplifiers/10__1113_slash_jp290107-115-5-10
    Average 96 stars, based on 1 article reviews
    axon amplifier - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    99
    Danaher Inc axon multiclamp 700b amplifier
    Axon Multiclamp 700b Amplifier, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/MultiClamp+700B+current+%26+patch+clamp+amplifier/pmc13687928-94-13-17
    Average 99 stars, based on 1 article reviews
    axon multiclamp 700b amplifier - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Danaher Inc multiclamp 700b amplifier
    Multiclamp 700b Amplifier, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/MultiClamp+700B+current+%26+patch+clamp+amplifier/pm42907500-595-6-9
    Average 99 stars, based on 1 article reviews
    multiclamp 700b amplifier - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Danaher Inc multiclamp 700b
    Multiclamp 700b, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/patch+clamp+amplifier/MultiClamp+700B+current+%26+patch+clamp+amplifier/pmc13682713-578-3-5
    Average 99 stars, based on 1 article reviews
    multiclamp 700b - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results