actim fecal blood test (Medix Biochemica)
90
Structured Review
Medix Biochemica
actim fecal blood test
Actim Fecal Blood Test, supplied by Medix Biochemica, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/oc-sensor+test+kit/actim+fecal+blood+test/pm22408764-80-159-163
Average 90 stars, based on 1 article reviews
Actim Fecal Blood Test, supplied by Medix Biochemica, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/oc-sensor+test+kit/actim+fecal+blood+test/pm22408764-80-159-163
Average 90 stars, based on 1 article reviews
actim fecal blood test - by Bioz Stars,
2026-10
90/100 stars
Images
Related Articles
other:Article Title: Assessment of fecal calprotectin and fecal occult blood as point-of-care markers for soil-transmitted helminth attributable intestinal morbidity in a case-control substudy conducted in Côte d'Ivoire, Lao PDR and Pemba Island, Tanzania Article Snippet: FC levels < 50 μg/g were interpreted as no Article Title: Analytical evaluation of eight qualitative FIT for haemoglobin products, for professional use in the UK. Article Snippet: Objectives: Qualitative faecal immunochemical tests for haemoglobin (FIT), for triaging for colorectal cancer investigations, are available for professional use.. The aim was to evaluate these lateral flow tests.. No previous analytical evaluations have been published. Article Title: [Diverging detection limits of immunochemical tests for occult blood underline the necessity of standardization and quality assurance]. Article Snippet: Hintergrund: Immunologische Tests auf Blut im Stuhl (FIT) sind den herkömmlichen, Guajac-basierten Tests in der Entdeckung von Darmkrebs und seinen Vorstufen überlegen.. Neben laborbasierten, quantitativen FITs kommen zunehmend auch qualitative Schnelltests zum Einsatz.. Aus bisherigen Studien ist bekannt, dass sich die Schnelltests deutlich in Sensitivität und Spezifität unterscheiden. Stripping Membranes:Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: .. To inform recommendations regarding how to replace the current gFOBT with a FIT in the population-based CRC screening program in Ontario, the expert panel evaluated existing evidence concerning the following three key aspects of FIT kit use: Table 1 Fecal immunochemical tests (FIT) with an active license approved for use by Health Canada* Manufacturer/distributor Device Product description Numerical or visual result Eiken†/Polymedco‡ OC-Auto Micro 80 FOB Test System (believed equivalent to OC-Hemodia) Flat tube, dipstick collection, machine developed Numerical Eiken/Polymedco OC-Sensor DIANA IFOB Test System (Assumed to be the same as OC-Auto Micro) Flat tube, dipstick collection, machine developed Numerical Alfresa Pharma Corporation§/Inverness Medical¶ I-FOBT Hemoglobin NS-Plus Flat tube, dipstick collection, machine developed Numerical Beckman Coulter** Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) Test card, applicator stick, on-card developed Visual Eiken/Polymedco OC-Light Manual IFOBT Long cylindrical tube, dipstick collection, test strip developed Visual Inverness Medical Clearview Ultra FOB Test Long cylindrical tube, dipstick collection, Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: Machine comes set at 100 ng/mL 280 samples per hour Used OC-Auto product insert and patient instructions Alfresa Pharma Corp / Inverness Medical I-FOBT Hemoglobin NS-Plus 2 Flat tube, dipstick collection, machine developed Vial 2 samples across 2 days Set by user 300 samples per hour Manufacturer’s marketing materials indicate the sample is 95% stable for 7 days at 25 ̊C, after 2 days at 37 ̊C stability drops to 90% then to 80% after 7 days, stable for 30 days at –40 ̊C, and after 2 days at 7 ̊C stability drops to 90% but stays at this for 20 days. .. Product insert and marketing slideshow obtained Beckman Coulter Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) 2 Test card, applicator stick, on card developed Card 3 samples across 3 days Unknown 2 min per test Manufacturer instructions say test is stable after sampling for 14 days at 15 ̊C–30 ̊C Product insert and patient instructions obtained Being used by Nova Scotia in pilot testing Eiken/ Polymedco OC-Light Manual IFOBT 2 Long cylindrical tube, dipstick collection, test strip developed Vial 1 sample over 1 day Unknown 5 min per test Polymedco states the specimen is stable for 15 days at 15 ̊C–30 ̊C or 30 days at 2 ̊C–8 ̊C No product insert obtained, information taken from www.ifobt. com/hp_ overmanualhtml Inverness Medical Clearview Ultra FOB Test 2 Long cylindrical tube, dipstick collection, test strip developed Vial 1 sample over 1 day 50 ng/mL 5 min per test Manufacturer states that specimen can be stored at 15 ̊C–30 ̊C for up to 5 days or 2 ̊C– 8 ̊C for up to 14 days Sampling:Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: .. To inform recommendations regarding how to replace the current gFOBT with a FIT in the population-based CRC screening program in Ontario, the expert panel evaluated existing evidence concerning the following three key aspects of FIT kit use: Table 1 Fecal immunochemical tests (FIT) with an active license approved for use by Health Canada* Manufacturer/distributor Device Product description Numerical or visual result Eiken†/Polymedco‡ OC-Auto Micro 80 FOB Test System (believed equivalent to OC-Hemodia) Flat tube, dipstick collection, machine developed Numerical Eiken/Polymedco OC-Sensor DIANA IFOB Test System (Assumed to be the same as OC-Auto Micro) Flat tube, dipstick collection, machine developed Numerical Alfresa Pharma Corporation§/Inverness Medical¶ I-FOBT Hemoglobin NS-Plus Flat tube, dipstick collection, machine developed Numerical Beckman Coulter** Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) Test card, applicator stick, on-card developed Visual Eiken/Polymedco OC-Light Manual IFOBT Long cylindrical tube, dipstick collection, test strip developed Visual Inverness Medical Clearview Ultra FOB Test Long cylindrical tube, dipstick collection, Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: Machine comes set at 100 ng/mL 280 samples per hour Used OC-Auto product insert and patient instructions Alfresa Pharma Corp / Inverness Medical I-FOBT Hemoglobin NS-Plus 2 Flat tube, dipstick collection, machine developed Vial 2 samples across 2 days Set by user 300 samples per hour Manufacturer’s marketing materials indicate the sample is 95% stable for 7 days at 25 ̊C, after 2 days at 37 ̊C stability drops to 90% then to 80% after 7 days, stable for 30 days at –40 ̊C, and after 2 days at 7 ̊C stability drops to 90% but stays at this for 20 days. .. Product insert and marketing slideshow obtained Beckman Coulter Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) 2 Test card, applicator stick, on card developed Card 3 samples across 3 days Unknown 2 min per test Manufacturer instructions say test is stable after sampling for 14 days at 15 ̊C–30 ̊C Product insert and patient instructions obtained Being used by Nova Scotia in pilot testing Eiken/ Polymedco OC-Light Manual IFOBT 2 Long cylindrical tube, dipstick collection, test strip developed Vial 1 sample over 1 day Unknown 5 min per test Polymedco states the specimen is stable for 15 days at 15 ̊C–30 ̊C or 30 days at 2 ̊C–8 ̊C No product insert obtained, information taken from www.ifobt. com/hp_ overmanualhtml Inverness Medical Clearview Ultra FOB Test 2 Long cylindrical tube, dipstick collection, test strip developed Vial 1 sample over 1 day 50 ng/mL 5 min per test Manufacturer states that specimen can be stored at 15 ̊C–30 ̊C for up to 5 days or 2 ̊C– 8 ̊C for up to 14 days Diagnostic Assay:Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: .. To inform recommendations regarding how to replace the current gFOBT with a FIT in the population-based CRC screening program in Ontario, the expert panel evaluated existing evidence concerning the following three key aspects of FIT kit use: Table 1 Fecal immunochemical tests (FIT) with an active license approved for use by Health Canada* Manufacturer/distributor Device Product description Numerical or visual result Eiken†/Polymedco‡ OC-Auto Micro 80 FOB Test System (believed equivalent to OC-Hemodia) Flat tube, dipstick collection, machine developed Numerical Eiken/Polymedco OC-Sensor DIANA IFOB Test System (Assumed to be the same as OC-Auto Micro) Flat tube, dipstick collection, machine developed Numerical Alfresa Pharma Corporation§/Inverness Medical¶ I-FOBT Hemoglobin NS-Plus Flat tube, dipstick collection, machine developed Numerical Beckman Coulter** Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) Test card, applicator stick, on-card developed Visual Eiken/Polymedco OC-Light Manual IFOBT Long cylindrical tube, dipstick collection, test strip developed Visual Inverness Medical Clearview Ultra FOB Test Long cylindrical tube, dipstick collection, Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: Machine comes set at 100 ng/mL 280 samples per hour Used OC-Auto product insert and patient instructions Alfresa Pharma Corp / Inverness Medical I-FOBT Hemoglobin NS-Plus 2 Flat tube, dipstick collection, machine developed Vial 2 samples across 2 days Set by user 300 samples per hour Manufacturer’s marketing materials indicate the sample is 95% stable for 7 days at 25 ̊C, after 2 days at 37 ̊C stability drops to 90% then to 80% after 7 days, stable for 30 days at –40 ̊C, and after 2 days at 7 ̊C stability drops to 90% but stays at this for 20 days. .. Product insert and marketing slideshow obtained Beckman Coulter Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) 2 Test card, applicator stick, on card developed Card 3 samples across 3 days Unknown 2 min per test Manufacturer instructions say test is stable after sampling for 14 days at 15 ̊C–30 ̊C Product insert and patient instructions obtained Being used by Nova Scotia in pilot testing Eiken/ Polymedco OC-Light Manual IFOBT 2 Long cylindrical tube, dipstick collection, test strip developed Vial 1 sample over 1 day Unknown 5 min per test Polymedco states the specimen is stable for 15 days at 15 ̊C–30 ̊C or 30 days at 2 ̊C–8 ̊C No product insert obtained, information taken from www.ifobt. com/hp_ overmanualhtml Inverness Medical Clearview Ultra FOB Test 2 Long cylindrical tube, dipstick collection, test strip developed Vial 1 sample over 1 day 50 ng/mL 5 min per test Manufacturer states that specimen can be stored at 15 ̊C–30 ̊C for up to 5 days or 2 ̊C– 8 ̊C for up to 14 days Article Title: Fecal immunochemical tests compared with guaiac fecal occult blood tests for population-based colorectal cancer screening. Article Snippet: There are also data that show the specimen can be kept for less than 3 days at 29 ̊C–34 ̊C but can be kept for at least 10–14 days at −18 ̊C to −24 ̊C Eiken/Polymedco OC-Sensor DIANA IFOB Test System Alfresa Pharma Corporation‡/ Inverness Medical§ I-FOBT Hemoglobin NS-Plus Manufacturer’s marketing materials indicate the specimen is 95% stable for 7 days at 25 ̊C, after 2 days at 37 ̊C stability drops to 90% then to 80% after 7 days, stable for 30 days at −40 ̊C, and after 2 days at 7 ̊C stability drops to 90% but stays at this for 20 days Beckman Coulter¶ Hemoccult ICT, Immunochemical Fecal Occult Blood Test (also known as Flexsure OBT) Manufacturer instructions say specimen is stable after sampling for 14 days at 15 ̊C–30 ̊C Eiken/Polymedco OC-Light Manual IFOBT Manufacturer states the specimen is stable for 15 days at 15 ̊C–30 ̊C or 30 days at 2 ̊C–8 ̊C Inverness Medical Clearview Ultra FOB Test Manufacturer states that specimen can be stored at 15 ̊C–30 ̊C for up to 5 days or 2 ̊C–8 ̊C for up to 14 days. .. Medix Biochemica** |