2d numerical simulations comsol multiphysics 4.4a (COMSOL Inc)
90
Structured Review
COMSOL Inc
2d numerical simulations comsol multiphysics 4.4a

2d Numerical Simulations Comsol Multiphysics 4.4a, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/numerical+simulation+package+comsol+multiphysics/2d+numerical+simulations+comsol+multiphysics+4+4a/pmc06509115-62-3-6
Average 90 stars, based on 1 article reviews

2d Numerical Simulations Comsol Multiphysics 4.4a, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/numerical+simulation+package+comsol+multiphysics/2d+numerical+simulations+comsol+multiphysics+4+4a/pmc06509115-62-3-6
Average 90 stars, based on 1 article reviews
2d numerical simulations comsol multiphysics 4.4a - by Bioz Stars,
2026-09
90/100 stars
Images
1) Product Images from "Facile tuning of the mechanical properties of a biocompatible soft material"
Article Title: Facile tuning of the mechanical properties of a biocompatible soft material
Journal: Scientific Reports
doi: 10.1038/s41598-019-43579-8
Figure Legend Snippet: On-chip temperature evaluation. ( a ) Cross section considered for temperature measurements and location of the relative positions of the thermocouples used to calibrate the temperature in real time. ( b ) Geometry used for the 2D numerical simulations. ( c ) Distribution of temperature at steady state, as obtained for the case T hot = 45 °C and T cold = 40 °C. ( d ) Temperature gradients across the channel length. In the schematic, the red horizontal arrow indicates the direction along which the temperature gradient is evaluated. The two graphs report the gradient of temperature inside the channel in the device with the PDMS membrane (left) and in the dummy device (right). In both cases the gradient is linear, with difference between the two situations being negligible.
Techniques Used: Membrane
Related Articles
Membrane:Article Title: Facile tuning of the mechanical properties of a biocompatible soft material. Article Snippet: measurements obtained from a dummy device, in which the PDMS membrane is substituted by a glass coverslip to improve thermal conductivity (Fig. 2). .. Additionally, we performed Article Title: Facile tuning of the mechanical properties of a biocompatible soft material Article Snippet: measurements obtained from a dummy device, in which the PDMS membrane is substituted by a glass coverslip to improve thermal conductivity (Fig. ). .. Additionally, we performed |