normal human complement (Quidel)
Structured Review

Normal Human Complement, supplied by Quidel, used in various techniques. Bioz Stars score: 95/100, based on 179 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/normal+human+complement+standard/pmc09090251-226-26-29?v=Quidel
Average 95 stars, based on 179 article reviews
Images
1) Product Images from "IgM anti-ACE2 autoantibodies in severe COVID-19 activate complement and perturb vascular endothelial function"
Article Title: IgM anti-ACE2 autoantibodies in severe COVID-19 activate complement and perturb vascular endothelial function
Journal: JCI Insight
doi: 10.1172/jci.insight.158362
Figure Legend Snippet: ( A ) Anti-ACE2 IgM antibodies from patient CV-1 or control do not inhibit ACE2 activity. Positive and negative controls were ACE2 alone, and ACE2 plus ACE2 inhibitor, respectively (see ). ( B ) IgM antibodies to ACE2 activate complement. Purified IgMs from anti-ACE2 IgM–positive COVID-19 patients ( n = 8) and healthy controls ( n = 11) was used for C1q binding assays. Values are means from 2 independent experiments performed on different days. *** P < 0.0001, Mann-Whitney test. (C–G) Anti-ACE2 IgM affects the pulmonary endothelium. ( C ) Phase image of a pulmonary microvessel (top). Fluorescence images of microvessels exposed to anti-ACE2–negative IgM (HC) or anti-ACE2–positive IgM (CV) after perfusion with 10 kDa dextran (lower). Representative images across n = 3 to 6 independent experiments for each IgM condition are shown. ( D ) ACE2 and CD31 microvessel staining following 24-hour perfusion with IFN-α/γ. Representative images across n = 3 independent experiments are shown. ( E ) C3c staining after perfusion with IFN and anti-ACE2–positive or control IgM (3.33 μg/mL). Representative images across n = 3 independent experiments are shown. ( F ) Permeability of microvessels perfused with IFN and anti-ACE2–positive IgM (CV) or anti-ACE2 negative IgM (HC) (100 μg/mL). D.L., detection limit. A linear mixed effects model was used to test the effect of anti-ACE2–positive IgM on permeability. n = 3 to 5 for each IgM condition; each dot represents an independent replicate. ( G ) Inhibition of microvessel permeability to 10 kDa dextran in response to anti-ACE2 IgM is IFN dependent. Low CV-1: 3.33 μg/mL; affinity-purified anti-ACE2 IgM: 100 ng/mL. To compare each condition to control, a Kruskal-Wallis test followed by Dunn’s multiple-comparison test was performed. n = 4 to 6 for each IgM condition; each dot represents an independent replicate.
Techniques Used: Control, Activity Assay, Purification, Binding Assay, MANN-WHITNEY, Fluorescence, Staining, Permeability, Inhibition, Affinity Purification, Comparison
