Review




Structured Review

BioDot Inc robotic microarrayer biodot ad3200
Robotic Microarrayer Biodot Ad3200, supplied by BioDot Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+inkjet+microarray/ad3200/us07700373-293-4-3
Average 90 stars, based on 1 article reviews
robotic microarrayer biodot ad3200 - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Diagnostic Assay:

Article Title: Colloidal gold and fluorescent immunochromatographic test strips for canine parvovirus detection.
Article Snippet: Canine parvovirus (CPV) is an acute and highly infectious virus causing disease in puppies and, thus, affecting the global dog industry.. The current CPV detection methods are limited by their sensitivity and specificity.. Hence, the current study sought to develop a rapid, sensitive, simple, and accurate immunochromatographic (ICS) test to detect and control the spread and prevalence of CPV infection.

Serial Dilution:

Article Title: An Adjuvanted Vaccine-Induced Pathogenesis Following Influenza Virus Infection.
Article Snippet: .. A serial dilution of a recombinant HA or an inactivated influenza antigen was spotted on a microarray slide to detect the level of the influenza A virus, H1N1-specific antibody response (AD3200, BioDot Inc., Irvine, CA, USA). ..

Recombinant:

Article Title: An Adjuvanted Vaccine-Induced Pathogenesis Following Influenza Virus Infection.
Article Snippet: .. A serial dilution of a recombinant HA or an inactivated influenza antigen was spotted on a microarray slide to detect the level of the influenza A virus, H1N1-specific antibody response (AD3200, BioDot Inc., Irvine, CA, USA). ..

Microarray:

Article Title: An Adjuvanted Vaccine-Induced Pathogenesis Following Influenza Virus Infection.
Article Snippet: .. A serial dilution of a recombinant HA or an inactivated influenza antigen was spotted on a microarray slide to detect the level of the influenza A virus, H1N1-specific antibody response (AD3200, BioDot Inc., Irvine, CA, USA). ..

Virus:

Article Title: An Adjuvanted Vaccine-Induced Pathogenesis Following Influenza Virus Infection.
Article Snippet: .. A serial dilution of a recombinant HA or an inactivated influenza antigen was spotted on a microarray slide to detect the level of the influenza A virus, H1N1-specific antibody response (AD3200, BioDot Inc., Irvine, CA, USA). ..

Control:

Article Title: Lateral flow colorimetric biosensor for detection of Vibrio parahaemolyticus based on hybridization chain reaction and aptamer.
Article Snippet: Vibrio parahaemolyticus (V. parahaemolyticus) is the causative agent for acute hepatopancreatic necrosis disease (AHPND) of shrimp, and it is also a common seafood-borne pathogen for humans.. Rapid and accurate identification of V. parahaemolyticus is helpful to diagnose the AHPND and ensure food safety.. Common detection methods suffer the deficiency of timeconsuming and complexed operation.

Modification:

Article Title: Protein Markers for the Differential Diagnosis of Vascular Dementia and Alzheimer's Disease
Article Snippet: .. Energy absorbing molecule (EAM) application was performed automatically using a modified Biodot AD3200 robot. ..

other:

Article Title: Microneedle-based skin patch for blood-free rapid diagnostic testing
Article Snippet: A solution of 200 μg/mL rabbit anti-mouse IgG H&L (Abcam, UK) and 800 μg/mL mouse anti- Plasmodium falciparum HRP2 IgM (ICL, Inc., OR) were dispensed on nitrocellulose membrane strips as control and test lines, respectively, using an automated liquid dispensing platform (BioDot, CA).



Similar Products

95
SCIENION non contact inkjet microarray printer
The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
Non Contact Inkjet Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+inkjet+microarray/sciFLEXARRAYER+S12/pmc13380757-243-19-23
Average 95 stars, based on 1 article reviews
non contact inkjet microarray printer - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

90
Arrayjet Limited non-contact inkjet microarray
(A) An example slide in which immunoglobulins in sera from different children were assayed. Each <t>microarray</t> slide comprised 24 mini-arrays (shown using the white boxes). Two example mini-arrays are enlarged: in the first mini-array a sample obtained from a one-day old neonate was analysed while in the second, serum from a two-month old infant was analysed. On each mini-array, peptide epitopes were printed and serum/mucosal samples incubated. Antibodies in patient samples that bound to peptide epitopes were identified using a cocktail of two detection antibodies: anti human IgG conjugated to Alex Fluor (AF) 647 (red fluorescent signal) and anti-human IgA conjugated to AF-555(green fluorescence). Spots with a yellow hue indicate antigens which were bound by both IgA and IgG in patient samples. Each peptide epitope was printed in duplicate: the locations of a selection of duplicate antigen pairs are shown. (B) The distribution of fluorescence signals from control spots. Each mini-array contained a set of positive control spots (comprising of an anti-human IgG that bound to all IgG immunoglobulins in the patient sample irrespective of antigenic specificity) and negative control spots (microarray printing buffer). Almost all negative control spots did not yield a fluorescent signal - i.e. median fluorescent intensity (MFI)=0. The positive control spots on the other hand yielded much higher MFIs, with most spots resulting in MFIs >10,000.
Non Contact Inkjet Microarray, supplied by Arrayjet Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+inkjet+microarray/arrayjet+microarrayer/bio_rxiv__462689-44-9-13
Average 90 stars, based on 1 article reviews
non-contact inkjet microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

Journal: iScience

Article Title: A rapid point-of-care test for vancomycin monitoring at the clinical bedside

doi: 10.1016/j.isci.2026.116064

Figure Lengend Snippet: The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

Article Snippet: Following polymerization, D4 assays were fabricated using non-contact inkjet printing methods as described elsewhere., VANC-BSA was printed using a non-contact inkjet microarray printer (Scienion, sciFLEXARRAYER Type S12).

Techniques: Polymer, Labeling, Dissolution, Diffusion-based Assay, Fluorescence, Concentration Assay

(A) An example slide in which immunoglobulins in sera from different children were assayed. Each microarray slide comprised 24 mini-arrays (shown using the white boxes). Two example mini-arrays are enlarged: in the first mini-array a sample obtained from a one-day old neonate was analysed while in the second, serum from a two-month old infant was analysed. On each mini-array, peptide epitopes were printed and serum/mucosal samples incubated. Antibodies in patient samples that bound to peptide epitopes were identified using a cocktail of two detection antibodies: anti human IgG conjugated to Alex Fluor (AF) 647 (red fluorescent signal) and anti-human IgA conjugated to AF-555(green fluorescence). Spots with a yellow hue indicate antigens which were bound by both IgA and IgG in patient samples. Each peptide epitope was printed in duplicate: the locations of a selection of duplicate antigen pairs are shown. (B) The distribution of fluorescence signals from control spots. Each mini-array contained a set of positive control spots (comprising of an anti-human IgG that bound to all IgG immunoglobulins in the patient sample irrespective of antigenic specificity) and negative control spots (microarray printing buffer). Almost all negative control spots did not yield a fluorescent signal - i.e. median fluorescent intensity (MFI)=0. The positive control spots on the other hand yielded much higher MFIs, with most spots resulting in MFIs >10,000.

Journal: bioRxiv

Article Title: Comprehensive profiling of antibodies against multiple infectious diseases in serum and the airway mucosa using synthetic peptide-based linear epitope microarrays

doi: 10.1101/462689

Figure Lengend Snippet: (A) An example slide in which immunoglobulins in sera from different children were assayed. Each microarray slide comprised 24 mini-arrays (shown using the white boxes). Two example mini-arrays are enlarged: in the first mini-array a sample obtained from a one-day old neonate was analysed while in the second, serum from a two-month old infant was analysed. On each mini-array, peptide epitopes were printed and serum/mucosal samples incubated. Antibodies in patient samples that bound to peptide epitopes were identified using a cocktail of two detection antibodies: anti human IgG conjugated to Alex Fluor (AF) 647 (red fluorescent signal) and anti-human IgA conjugated to AF-555(green fluorescence). Spots with a yellow hue indicate antigens which were bound by both IgA and IgG in patient samples. Each peptide epitope was printed in duplicate: the locations of a selection of duplicate antigen pairs are shown. (B) The distribution of fluorescence signals from control spots. Each mini-array contained a set of positive control spots (comprising of an anti-human IgG that bound to all IgG immunoglobulins in the patient sample irrespective of antigenic specificity) and negative control spots (microarray printing buffer). Almost all negative control spots did not yield a fluorescent signal - i.e. median fluorescent intensity (MFI)=0. The positive control spots on the other hand yielded much higher MFIs, with most spots resulting in MFIs >10,000.

Article Snippet: Peptides were printed onto the epoxy slides using a non-contact inkjet microarray printer (Arrayjet, Scotland).

Techniques: Microarray, Incubation, Fluorescence, Selection, Positive Control, Negative Control

The kinetics of maternal antibody decay were evaluated for five antigens on the peptide microarray chip. Changes in the levels of antigen-specific IgG in (A) serum and (B) airway mucosa, were analysed using loess curve fitting. For all antigens except SPNE, there was evidence of serum IgG decline in the first three months of life. In the airway mucosa similar changes in antigen specific IgG were observed. The dashed red lines indicate the 6-month age time point while the blue dashed line indicates the 12-month time point.

Journal: bioRxiv

Article Title: Comprehensive profiling of antibodies against multiple infectious diseases in serum and the airway mucosa using synthetic peptide-based linear epitope microarrays

doi: 10.1101/462689

Figure Lengend Snippet: The kinetics of maternal antibody decay were evaluated for five antigens on the peptide microarray chip. Changes in the levels of antigen-specific IgG in (A) serum and (B) airway mucosa, were analysed using loess curve fitting. For all antigens except SPNE, there was evidence of serum IgG decline in the first three months of life. In the airway mucosa similar changes in antigen specific IgG were observed. The dashed red lines indicate the 6-month age time point while the blue dashed line indicates the 12-month time point.

Article Snippet: Peptides were printed onto the epoxy slides using a non-contact inkjet microarray printer (Arrayjet, Scotland).

Techniques: Peptide Microarray