Review




Structured Review

DestiNA Genomics Ltd destina probes
Destina Probes, supplied by DestiNA Genomics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+inkjet+microarray/destina+probes/pmc03436018-62-12-12
Average 90 stars, based on 1 article reviews
destina probes - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Blocking Assay:

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: In a first phase of this feasibility study, a protocol to print DestiNA probes onto LoC using an inkjet printer was developed. .. Once the printing and blocking conditions were optimised, a second phase was carried out in order to check if DestiNA probes, covalently immobilized on the LoC, were able to form duplexes with complementary synthetic sRNA oligomers. ..

Microarray:

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: .. Printing was performed using a proprietary non-contact inkjet printing process in which DestiNA probes were deposited uniformly onto the LoC microarray area. ..

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: .. DestiNA probes were reacted chemoselectivity with the epoxy groups that coat the silicon-based microarray surface of the In-Check LoC. shows an amino-modified DestiNA probe reacting with the epoxysilane surface of the LoC (a reaction that does not need additional baking or UV cross-linking steps). .. Molecular spacers (PEG group) between the probes and the LoC epoxy groups facilitate interactions between the printed DestiNA probes and their target binding partners in solution.

Modification:

Article Title: PNA probe
Article Snippet: .. In this method, DestiNA probes (from 10 to 100 μM solutions) modified at their N-terminal with an amino-pegylated group were immobilised onto Immunodyne ABC (activated nylon 6.6 membranes from Pall). .. DestiNA master mix was prepared with 30 μL of SMART-C-PEG-Biotin (SMART “Reader Base”) (100 μM), 45 μL of nucleic acid strands (KWT DNA and K12S DNA) at 100 nM or 45 uL PCR KWT and K12S and 20 μL of reducing agent, sodium cyanoborohydride (15 mM) and 205 μL of citrate buffer 0.1M with 0.1% SDS (pH 6).

Mass Spectrometry:

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: .. DestiNA probes terminate with an amino PEG group and were prepared by solid-phase synthesis (SPS) using Fmoc/Bhoc protected monomers as described previously [ ] and were characterized by MALDI-TOF mass spectrometry (see ). ..

other:

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: Briefly, DestiNA core technology takes advantage of dynamic chemistry for nucleic acid sequence specific recognition using aldehyde-modified natural nucleobases (so called SMART nucleobases), and probes based on peptide nucleic acid (PNA), containing an “abasic” position (DestiNA probes) which can be made complementary to any target nucleic acid sequence ( ) [ ].

Diagnostic Assay:

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: All the key proof of concept objectives were achieved, including effective DestiNA probe printing and DestiNA reactions, demonstrating successful translation of DestiNA reagents onto the In Check LoC platform. .. This study represents a first step in merging the two technologies to create a suite of novel medical diagnostic assays capable of delivering a novel biochip platform for the rapid detection of nucleic acids with high sensitivity and specificity.By combining the novel chemical-based methods with the Lab-on-Chip platform, clinically valuable innovation is achieved through: The unique high affinity and selective hybridisation between DestiNA probes and target DNA or RNA, superior to standard DNA/DNA or DNA/RNA hybridisations. .. The innovative DestiNA probes, that contain a “blank”/nucleobase free position within the probe, enable a unique proof-reading step to occur.

Hybridization:

Article Title: Novel Biochip Platform for Nucleic Acid Analysis
Article Snippet: All the key proof of concept objectives were achieved, including effective DestiNA probe printing and DestiNA reactions, demonstrating successful translation of DestiNA reagents onto the In Check LoC platform. .. This study represents a first step in merging the two technologies to create a suite of novel medical diagnostic assays capable of delivering a novel biochip platform for the rapid detection of nucleic acids with high sensitivity and specificity.By combining the novel chemical-based methods with the Lab-on-Chip platform, clinically valuable innovation is achieved through: The unique high affinity and selective hybridisation between DestiNA probes and target DNA or RNA, superior to standard DNA/DNA or DNA/RNA hybridisations. .. The innovative DestiNA probes, that contain a “blank”/nucleobase free position within the probe, enable a unique proof-reading step to occur.



Similar Products

95
SCIENION non contact inkjet microarray printer
The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
Non Contact Inkjet Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+inkjet+microarray/sciFLEXARRAYER+S12/pmc13380757-243-19-23
Average 95 stars, based on 1 article reviews
non contact inkjet microarray printer - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

90
Arrayjet Limited non-contact inkjet microarray
(A) An example slide in which immunoglobulins in sera from different children were assayed. Each <t>microarray</t> slide comprised 24 mini-arrays (shown using the white boxes). Two example mini-arrays are enlarged: in the first mini-array a sample obtained from a one-day old neonate was analysed while in the second, serum from a two-month old infant was analysed. On each mini-array, peptide epitopes were printed and serum/mucosal samples incubated. Antibodies in patient samples that bound to peptide epitopes were identified using a cocktail of two detection antibodies: anti human IgG conjugated to Alex Fluor (AF) 647 (red fluorescent signal) and anti-human IgA conjugated to AF-555(green fluorescence). Spots with a yellow hue indicate antigens which were bound by both IgA and IgG in patient samples. Each peptide epitope was printed in duplicate: the locations of a selection of duplicate antigen pairs are shown. (B) The distribution of fluorescence signals from control spots. Each mini-array contained a set of positive control spots (comprising of an anti-human IgG that bound to all IgG immunoglobulins in the patient sample irrespective of antigenic specificity) and negative control spots (microarray printing buffer). Almost all negative control spots did not yield a fluorescent signal - i.e. median fluorescent intensity (MFI)=0. The positive control spots on the other hand yielded much higher MFIs, with most spots resulting in MFIs >10,000.
Non Contact Inkjet Microarray, supplied by Arrayjet Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+inkjet+microarray/arrayjet+microarrayer/bio_rxiv__462689-44-9-13
Average 90 stars, based on 1 article reviews
non-contact inkjet microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

Journal: iScience

Article Title: A rapid point-of-care test for vancomycin monitoring at the clinical bedside

doi: 10.1016/j.isci.2026.116064

Figure Lengend Snippet: The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

Article Snippet: Following polymerization, D4 assays were fabricated using non-contact inkjet printing methods as described elsewhere., VANC-BSA was printed using a non-contact inkjet microarray printer (Scienion, sciFLEXARRAYER Type S12).

Techniques: Polymer, Labeling, Dissolution, Diffusion-based Assay, Fluorescence, Concentration Assay

(A) An example slide in which immunoglobulins in sera from different children were assayed. Each microarray slide comprised 24 mini-arrays (shown using the white boxes). Two example mini-arrays are enlarged: in the first mini-array a sample obtained from a one-day old neonate was analysed while in the second, serum from a two-month old infant was analysed. On each mini-array, peptide epitopes were printed and serum/mucosal samples incubated. Antibodies in patient samples that bound to peptide epitopes were identified using a cocktail of two detection antibodies: anti human IgG conjugated to Alex Fluor (AF) 647 (red fluorescent signal) and anti-human IgA conjugated to AF-555(green fluorescence). Spots with a yellow hue indicate antigens which were bound by both IgA and IgG in patient samples. Each peptide epitope was printed in duplicate: the locations of a selection of duplicate antigen pairs are shown. (B) The distribution of fluorescence signals from control spots. Each mini-array contained a set of positive control spots (comprising of an anti-human IgG that bound to all IgG immunoglobulins in the patient sample irrespective of antigenic specificity) and negative control spots (microarray printing buffer). Almost all negative control spots did not yield a fluorescent signal - i.e. median fluorescent intensity (MFI)=0. The positive control spots on the other hand yielded much higher MFIs, with most spots resulting in MFIs >10,000.

Journal: bioRxiv

Article Title: Comprehensive profiling of antibodies against multiple infectious diseases in serum and the airway mucosa using synthetic peptide-based linear epitope microarrays

doi: 10.1101/462689

Figure Lengend Snippet: (A) An example slide in which immunoglobulins in sera from different children were assayed. Each microarray slide comprised 24 mini-arrays (shown using the white boxes). Two example mini-arrays are enlarged: in the first mini-array a sample obtained from a one-day old neonate was analysed while in the second, serum from a two-month old infant was analysed. On each mini-array, peptide epitopes were printed and serum/mucosal samples incubated. Antibodies in patient samples that bound to peptide epitopes were identified using a cocktail of two detection antibodies: anti human IgG conjugated to Alex Fluor (AF) 647 (red fluorescent signal) and anti-human IgA conjugated to AF-555(green fluorescence). Spots with a yellow hue indicate antigens which were bound by both IgA and IgG in patient samples. Each peptide epitope was printed in duplicate: the locations of a selection of duplicate antigen pairs are shown. (B) The distribution of fluorescence signals from control spots. Each mini-array contained a set of positive control spots (comprising of an anti-human IgG that bound to all IgG immunoglobulins in the patient sample irrespective of antigenic specificity) and negative control spots (microarray printing buffer). Almost all negative control spots did not yield a fluorescent signal - i.e. median fluorescent intensity (MFI)=0. The positive control spots on the other hand yielded much higher MFIs, with most spots resulting in MFIs >10,000.

Article Snippet: Peptides were printed onto the epoxy slides using a non-contact inkjet microarray printer (Arrayjet, Scotland).

Techniques: Microarray, Incubation, Fluorescence, Selection, Positive Control, Negative Control

The kinetics of maternal antibody decay were evaluated for five antigens on the peptide microarray chip. Changes in the levels of antigen-specific IgG in (A) serum and (B) airway mucosa, were analysed using loess curve fitting. For all antigens except SPNE, there was evidence of serum IgG decline in the first three months of life. In the airway mucosa similar changes in antigen specific IgG were observed. The dashed red lines indicate the 6-month age time point while the blue dashed line indicates the 12-month time point.

Journal: bioRxiv

Article Title: Comprehensive profiling of antibodies against multiple infectious diseases in serum and the airway mucosa using synthetic peptide-based linear epitope microarrays

doi: 10.1101/462689

Figure Lengend Snippet: The kinetics of maternal antibody decay were evaluated for five antigens on the peptide microarray chip. Changes in the levels of antigen-specific IgG in (A) serum and (B) airway mucosa, were analysed using loess curve fitting. For all antigens except SPNE, there was evidence of serum IgG decline in the first three months of life. In the airway mucosa similar changes in antigen specific IgG were observed. The dashed red lines indicate the 6-month age time point while the blue dashed line indicates the 12-month time point.

Article Snippet: Peptides were printed onto the epoxy slides using a non-contact inkjet microarray printer (Arrayjet, Scotland).

Techniques: Peptide Microarray