Review



flexible loop wire nitinol suture passing wire  (Arthrex Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Arthrex Inc flexible loop wire nitinol suture passing wire
    Flexible Loop Wire Nitinol Suture Passing Wire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+suture+passing+wire/pmc12177378-37-2-10
    Average 90 stars, based on 1 article reviews
    flexible loop wire nitinol suture passing wire - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Refixierung von osteochondralen Flake-Frakturen nach Patellaluxation – die Parachute-Technik
    Article Snippet: Flexibler Führungsdraht, um die Fäden transpatellar zu shuttlen (Nitinol Suture Passing Wire, Arthrex, Naples, FL, USA) Arthroskopie (nicht obligat)

    Article Title: Biomechanical comparison of four isometric prosthetic ligament repair techniques for tarsal medial collateral ligament injury.
    Article Snippet: Two strands of UHMWPE suture were threaded through a 2-hole oblong 2.7-mm titanium button placed on the lateral aspect of the calcaneal tunnel; the suture ends were then pulled through the tunnel using a nitinol suture passer (Arthrex Inc).

    Article Title: A Technique to Augment Arthroscopic Bankart Repair With or Without a Metal Block: A Comparison.
    Article Snippet: Step 4: Implant Positioning The arthroscope is maintained in the AL portal and two suture passers (Nitinol, Arthrex, Naples, FL, USA) are shuttled through the cannulated drills, exiting via the AM portal.

    Article Title: Refixierung von osteochondralen Flake-Frakturen nach Patellaluxation – die Parachute-Technik
    Article Snippet: Flexibler Faden-Führungsdraht (Nitinol Suture Passing Wire, Fa. Arthrex, Naples, FL, USA) , Transpatellares Shuttlen der Fäden.

    Article Title: A Technique to Augment Arthroscopic Bankart Repair With or Without a Metal Block: A Comparison
    Article Snippet: The arthroscope is maintained in the AL portal and two suture passers (Nitinol, Arthrex, Naples, FL, USA) are shuttled through the cannulated drills, exiting via the AM portal.

    Article Title: Short-term outcomes of 43 dogs treated with arthroscopic suturing for meniscal tears associated with cranial cruciate ligament disease.
    Article Snippet: Correspondence Kali A. Holz, Espanola Animal Hospital, Greater Sudbury, Ontario, Canada.. Email: kaliholz@icloud.com Abstract Objective: To describe short-term outcomes and complications in dogs receiving meniscal suturing and concurrent tibial plateau leveling osteotomy (TPLO) with or without augmentation with an extracapsular suture.. Study design: Retrospective case series.

    Article Title: Radial Head Osteochondral Flake Refixation With a Transosseous All-Suture Technique
    Article Snippet: Using a flexible loop wire (e.g., Nitinol Suture Passing Wire; Arthrex), 2 resorbable No. 2 sutures (e.g., No. 2 Vicryl; Ethicon) are passed through the fragment using a U-suture technique ( ).

    Article Title: A Technique to Augment Arthroscopic Bankart Repair With or Without a Metal Block: A Comparison.
    Article Snippet: he arthroscope is maintained in the AL portal and two suture passers (Nitinol, Arthrex, Naples, FL, USA) are shuttled through the cannulated drills, exiting via the AM portal.



    Similar Products

    86
    Arthrex Inc nitinol wire loop
    Nitinol Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+wire/pm41324432-58-8-11
    Average 86 stars, based on 1 article reviews
    nitinol wire loop - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Arthrex Inc nitinol wire shuttle loop
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Nitinol Wire Shuttle Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+wire/pmc12255420-56-4-25
    Average 90 stars, based on 1 article reviews
    nitinol wire shuttle loop - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Arthrex Inc nitinol wire shuttle loop with a passing hook
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Nitinol Wire Shuttle Loop With A Passing Hook, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+wire+shuttle+loop+with+a+passing+hook/pmc12255420-59-7-9
    Average 90 stars, based on 1 article reviews
    nitinol wire shuttle loop with a passing hook - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Arthrex Inc flexible loop wire nitinol suture passing wire
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Flexible Loop Wire Nitinol Suture Passing Wire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+suture+passing+wire/pmc12177378-37-2-10
    Average 90 stars, based on 1 article reviews
    flexible loop wire nitinol suture passing wire - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Arthrex Inc looped nitinol wire
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Looped Nitinol Wire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+wire+loop/pm40265467-55-6-21
    Average 90 stars, based on 1 article reviews
    looped nitinol wire - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    86
    Arthrex Inc nitinol loop wire
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Nitinol Loop Wire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/nitinol+wire/10__30795_slash_jfootankle__2024__v18__1817-159-3-11
    Average 86 stars, based on 1 article reviews
    nitinol loop wire - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Arthrex Inc micro suture lasso small curve with nitinol wire loop
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Micro Suture Lasso Small Curve With Nitinol Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/micro+suture+lasso+small+curve+with+nitinol+wire+loop/pm38760631-31-29-32
    Average 90 stars, based on 1 article reviews
    micro suture lasso small curve with nitinol wire loop - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Arthrex Inc suturelasso nitinol wire loop
    <t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
    Suturelasso Nitinol Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nitinol+loop+wire/micro+suture+lasso+small+curve+with+nitinol+wire+loop/pm36113026-32-2-6
    Average 90 stars, based on 1 article reviews
    suturelasso nitinol wire loop - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Shuttle loop preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A nitinol wire shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.

    Journal: Arthroscopy Techniques

    Article Title: Autologous Long Head of Biceps Tendon With High-Strength Suture for Reconstruction of Coracoclavicular Ligament

    doi: 10.1016/j.eats.2025.103465

    Figure Lengend Snippet: Shuttle loop preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A nitinol wire shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.

    Article Snippet: Under arthroscopic visualization, a nitinol wire shuttle loop is passed around the base of the coracoid from medial to lateral with a passing hook (AR-7806; Arthrex), which is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury ( A).

    Techniques: