Review




Structured Review

Axion BioSystems multi-electrode array mea well
Multi Electrode Array Mea Well, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/us12223643-161-7-12
Average 90 stars, based on 1 article reviews
multi-electrode array mea well - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Supporting Information for Pairwise biosynthesis of ion channels stabilizes excitability and mitigates arrhythmias
Article Snippet: Multielectrode Array (MEA) Electrical activity from iPSC-CM monolayers was recorded using multielectrode array (MEA) (Maestro Pro, Axion Biosystems).

Article Title: Generation and applications of cardiac spheroids
Article Snippet: These include the use of an optical mapping system (MappingLab Ltd, Manchester, United Kingdom) for simultaneous recording of action potential and calcium imaging based on fluorescence signals119, as well as the use of microplate electrode array (MEA) plates, like the Maestro Pro (Axion Biosystems, Atlanta, USA) which offers scalable, label-free and automated reading in 96-well formats over days to months if required.

Microelectrode Array:

Article Title: Epitranscriptomic Modulation of TET2 Inhibition Suppressed SARS-CoV-2 Infection and Blocked Viral Nucleocapsid Protein in Induced-Pluripotent-Stem-Cell-Derived Cardiomyocyte Screening Models
Article Snippet: .. CytoView MEA plates (Axion BioSystems, Atlanta, GA, USA) were coated with Geltrex and seeded with hiPSC-CMs [ ]. .. The effects of cardiotropic drugs on the electrophysiological properties of hiPSC-CMs were recorded using the Maestro Pro system and analyzed with the Cardiac Analysis Software v.3.1.8 (Axion BioSystems).

Article Title: Neuronal aging causes mislocalization of splicing proteins and unchecked cellular stress.
Article Snippet: .. Mature transdifferentiated neurons were seeded onto PDL-/PLO-/ laminin-coated Cytoview MEA 48 plate (Axion Biosystems, M768-tMEA48B). ..

Article Title: Synaptic and intrinsic membrane defects disrupt early neural network dynamics in Down syndrome
Article Snippet: Mouse astrocytes (ScienCell; SC-M1800) were expanded in AM astrocyte medium (ScienCell; SC-1831) supplemented with foetal bovine serum (FBS; ThermoFisher; 0010), astrocyte growth supplement (ScienCell; 1882) and penicillin/ streptomycin (ScienCell; 0503). .. For neuronal differentiation, isogenic NSCs were seeded onto glass coverslips and microelectrode array (MEA) plates (Axion biosystems; M384-tMEA-6W). .. Sterile coverslips in 24- well plates were coated with 400 μl of poly-L-ornithine (PLO: Millipore Sigma; P4957-50ML) at 37°C overnight.

Article Title: Neuronal aging causes mislocalization of splicing proteins and unchecked cellular stress
Article Snippet: .. Mature transdifferentiated neurons were seeded onto PDL-/PLO-/laminin-coated Cytoview MEA 48 plate (Axion Biosystems, M768-tMEA-48B). ..

Article Title: Graphene-polymer nanofibers enable optically induced electrical responses in stem cell-derived electrically excitable cells and brain organoids.
Article Snippet: Human pluripotent stem cell (hPSC)-derived electrically excitable cells provide a unique window into development, but they remain electrically immature partially due to the lack of chronic stimulation.. Here, we fabricated electrospun polymer nanofibers containing light-reactive reduced graphene oxide (rGO) as part of a new classes of on-demand, electrically active biomaterials to enhance cell function.. Fiber size, stiffness, and electrical conductivity varied with rGO concentration, which impacted hPSC-derived cardiomyocyte and neuron responses; with acute light stimulation, cardiomyocytes exhibited increased, synchronous calcium handling.

Sterility:

Article Title: Graphene-polymer nanofibers enable optically induced electrical responses in stem cell-derived electrically excitable cells and brain organoids.
Article Snippet: Human pluripotent stem cell (hPSC)-derived electrically excitable cells provide a unique window into development, but they remain electrically immature partially due to the lack of chronic stimulation.. Here, we fabricated electrospun polymer nanofibers containing light-reactive reduced graphene oxide (rGO) as part of a new classes of on-demand, electrically active biomaterials to enhance cell function.. Fiber size, stiffness, and electrical conductivity varied with rGO concentration, which impacted hPSC-derived cardiomyocyte and neuron responses; with acute light stimulation, cardiomyocytes exhibited increased, synchronous calcium handling.



Similar Products

90
Axion BioSystems multi-electrode array mea well
Multi Electrode Array Mea Well, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/us12223643-161-7-12
Average 90 stars, based on 1 article reviews
multi-electrode array mea well - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array (mea) 48-well plates axion biosystems #m768-tmea-48b
Multi Electrode Array (Mea) 48 Well Plates Axion Biosystems #M768 Tmea 48b, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/m768+glx+12+well+plates/pmc11631337-84-25-33
Average 90 stars, based on 1 article reviews
multi-electrode array (mea) 48-well plates axion biosystems #m768-tmea-48b - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array (mea) 24-well plates
Multi Electrode Array (Mea) 24 Well Plates, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11538552-94-5-11
Average 90 stars, based on 1 article reviews
multi-electrode array (mea) 24-well plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array (mea) 48-well plates
Multi Electrode Array (Mea) 48 Well Plates, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pm39441987-78-35-42
Average 90 stars, based on 1 article reviews
multi-electrode array (mea) 48-well plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Mcs GmbH multiwell multi-electrode array (mea) system comprising 24 individual wells with 12 electrodes per well
Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a <t>multi-electrode</t> array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.
Multiwell Multi Electrode Array (Mea) System Comprising 24 Individual Wells With 12 Electrodes Per Well, supplied by Mcs GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/256+electrode+mea/pmc11484056-73-20-26
Average 90 stars, based on 1 article reviews
multiwell multi-electrode array (mea) system comprising 24 individual wells with 12 electrodes per well - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems axion e-stim+ classic multi-electrode array (mea) 48-well plate
Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a <t>multi-electrode</t> array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.
Axion E Stim+ Classic Multi Electrode Array (Mea) 48 Well Plate, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+48/pm39189070-169-73-80
Average 90 stars, based on 1 article reviews
axion e-stim+ classic multi-electrode array (mea) 48-well plate - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems e-stim+ classic multi-electrode array (mea) 48-well plate
Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a <t>multi-electrode</t> array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.
E Stim+ Classic Multi Electrode Array (Mea) 48 Well Plate, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11381919-152-75-82
Average 90 stars, based on 1 article reviews
e-stim+ classic multi-electrode array (mea) 48-well plate - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems micro-electrode array (mea) multi-well plates
All experiments were undertaken in DIV12 cultures cultured in <t>CytoView</t> micro-electrode array <t>(MEA)</t> multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).
Micro Electrode Array (Mea) Multi Well Plates, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11189525-246-9-20
Average 90 stars, based on 1 article reviews
micro-electrode array (mea) multi-well plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array well-based system mea
All experiments were undertaken in DIV12 cultures cultured in <t>CytoView</t> micro-electrode array <t>(MEA)</t> multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).
Multi Electrode Array Well Based System Mea, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11239925-141-6-8
Average 90 stars, based on 1 article reviews
multi-electrode array well-based system mea - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a multi-electrode array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.

Journal: Frontiers in Neuroscience

Article Title: Human sensory-like neuron cultivation—An optimized protocol

doi: 10.3389/fnins.2024.1429694

Figure Lengend Snippet: Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a multi-electrode array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.

Article Snippet: The electrical activity of iSNs was assessed using a multiwell multi-electrode array (MEA) system comprising 24 individual wells with 12 electrodes per well (Multi Channel Systems MCS GmbH, Reutlingen, Germany).

Techniques: Viability Assay, Generated, Marker, Activity Assay, Immunocytochemistry

All experiments were undertaken in DIV12 cultures cultured in CytoView micro-electrode array (MEA) multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).

Journal: Cell Death & Disease

Article Title: Tau P301L disengages from the proteosome core complex and neurogranin coincident with enhanced neuronal network excitability

doi: 10.1038/s41419-024-06815-2

Figure Lengend Snippet: All experiments were undertaken in DIV12 cultures cultured in CytoView micro-electrode array (MEA) multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).

Article Snippet: All experiments were undertaken in DIV12 cultures cultured in CytoView micro-electrode array (MEA) multi-well plates using the Maestro-Pro MEA system (Axion Biosystems).

Techniques: Cell Culture, Activity Assay, Microscopy, Transduction, Expressing