Review




Structured Review

Nidek CO device mp3
Device Mp3, supplied by Nidek CO, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/mp+3/pm32235121-59-1-3
Average 90 stars, based on 1 article reviews
device mp3 - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Imaging:

Article Title: Repeatability of Microperimetry in areas of RPE and Photoreceptor loss in Geographic Atrophy supported by AI-based OCT biomarker quantification.
Article Snippet: .. Figure 1: 45 stimuli study grid for MP examinations of a patient with geographic atrophy using CenterVue (iCare) MAIA (A) and Nidek MP3 (B) Figure 2: Automated imaging biomarker segmentation of a patient with a foveal sparing geographic atrophy. ..

Biomarker Discovery:

Article Title: Repeatability of Microperimetry in areas of RPE and Photoreceptor loss in Geographic Atrophy supported by AI-based OCT biomarker quantification.
Article Snippet: .. Figure 1: 45 stimuli study grid for MP examinations of a patient with geographic atrophy using CenterVue (iCare) MAIA (A) and Nidek MP3 (B) Figure 2: Automated imaging biomarker segmentation of a patient with a foveal sparing geographic atrophy. ..

other:

Article Title: Normative prospective data on automatically quantified retinal morphology correlated to retinal function in healthy ageing eyes by two microperimetry devices
Article Snippet: Healthy subjects above 50 years were examined using two MP devices, MP‐3 (NIDEK) and MAIA (iCare).

Article Title: A comprehensive review of structure-function correlations in age-related macular degeneration: Contributions of microperimetry.
Article Snippet: Study Number of eyes included AMD stage and staging system MP (device and lighting conditions) Structural imaging for structurefunction correlations Study design Structural parameters significantly associated with decreased RS Structural parameters not significantly associated with RS Roh et al, 2019 96 102 AMD eyes, 46 control eyes Early, intermediate, late AMD, AREDS staging MAIA, mesopic SD-OCT, SS-OCT Prospective, cross-sectional Advanced AMD, reduced retinal thickness, ellipsoid disruption, SRF, atrophy, fibrosis, outer retinal tubulation (multivariable analysis) Choroidal thickness, classic drusen, SDD, HRF, IRF, CNV, SPED (multivariable analysis) Broadhead et al, 2016 6 72 AMD eyes, 36 control eyes Mild/moderate AMD (AREDS grades 2–3), AREDS staging MAIA, mesopic Enhanced depth imaging OCT (EDIOCT) Prospective, cross-sectional Retinal thickness Choroidal thickness Wu et al, 2016 141 39 AMD eyes Early stages of AMD MAIA, mesopic SD-OCT Prospective, longitudinal RPEDC layer thickness, number of HRF Inner retinal migration of HRF (represented by a weighted axial distribution score; AxD), number of atrophic areas (nGA and drusen-associated atrophy) Liu et al, 2023 60 22 AMD eyes Intermediate AMD, Beckman classification MAIA, mesopic SD-OCT Retrospective, cross-sectional Presence of HRF HRF number, qualitative features of HRF (separation from the RPE, location above drusen, and shadowing of the underlying structures) Saßmannshausen et al, 2023 105 40 AMD eyes, 29 control eyes Intermediate AMD, Beckman classification Nidek MP− 1S, mesopic and scotopic SD-OCT Cross-sectional HRF area – associated with mesopic sensitivity loss HRF area – not associated with scotopic sensitivity loss Reiter et al, 2023 93 51 AMD eyes Early or intermediate AMD, Beckman classification Nidek MP− 3, mesopic SD-OCT Prospective, longitudinal Drusen volume and HRF volume (multivariate model) Saßmannshausen et al, 2018 104 35 AMD eyes, 29 control eyes Intermediate AMD, Beckman classification Nidek MP− 1S, mesopic and scotopic SD-OCT Prospective, cross-sectional Increased thickness of the total retina and the RPEDC; decreased thickness of the ONL and the photoreceptor-segments – mesopic and scotopic sensitivity Thickness of the inner retina Saßmannshausen et al, 2021 106 59 AMD eyes, 27 control eyes Intermediate AMD, Beckman classification Nidek MP− 1S, mesopic and scotopic SD-OCT Prospective, longitudinal Univariate linear mixed-effect models: ONL thickness, full retinal thickness, RPEDC thickness – mesopic and scotopic sensitivity Combined linear mixed-effect models: ONL and RPEDC thickness – mesopic sensitivity; full retinal thickness, inner retinal thickness, ONL and photoreceptor IS+OS thickness – scotopic sensitivity.

Article Title: Influence of OCT biomarkers on microperimetry intra- and interdevice repeatability in diabetic macular edema.
Article Snippet: To evaluate the intraand interdevice repeatability of microperimetry (MP) assessments in patients with diabetic macular edema (DME) two consecutive MP testings (45 fovea-centered stimuli, 4–2 staircase strategy) were performed using MP3 (NIDEK, Aichi, Japan) and MAIA (CenterVue, Padova, Italy), respectively.

Article Title: Normative prospective data on automatically quantified retinal morphology correlated to retinal function in healthy ageing eyes by two microperimetry devices
Article Snippet: At the same visit two successive MP examinations were performed on the MP‐3 (NIDEK CO., Ltd., Gamagori, Japan) and MAIA (MAIA, iCare S.p.A., Padova, Italy) resulting in a total of four examinations.

Article Title: Functional diabetic retinopathy: A new concept to improve management of diabetic retinal diseases.
Article Snippet: It uses a LCD to present stimuli and simultaneous SLO scans for fundus examination, and a camera to capture fundus images with automated fundus tracking.70,74 OPKO/OTI (OPKO Instrumentation, Miami, FL) subsequently introduced spectral OCT SLO, which offers the advantage of correlating functional deficits with SLO infrared images and also bidimensional cross-sectional OCT retinal images.70 Another advantage is that the SLO imaging is nonmydriatic and the function is quite immune to change in pupil size.75 Nidek MP-3 is the newest version with wider range of stimulus intensity of 0–34 decibel (dB) and provides better test-retest reproducibility.76 CenterVue Macular Integrity Assessment (MAIA) (CenterVue, Padova, Italy) is a recent development and is quite similar to the Nidek MP-3.70 Some of the limitations of microperimetry include limited dynamic range of stimulus intensity resulting floor effects, and the available devices lack false-negative index to measure reliability of patients.77

Article Title: A comprehensive review of structure-function correlations in age-related macular degeneration: Contributions of microperimetry.
Article Snippet: The studies included in this review have significant variation in terms of the microperimeters used (Nidek MP-1 or MP-1S, Nidek MP-3, MAIA, S-MAIA, OPKO-OTI Spectral OCT/SLO, OPKO Health SLO microperimeter and Rodenstock SLO microperimeter), MP testing grids (variations in the number of stimuli and their distribution in the macular region) and lighting conditions (scotopic/mesopic/photopic).

Article Title: Topographic and quantitative correlation of structure and function using deep learning in subclinical biomarkers of intermediate age-related macular degeneration.
Article Snippet: All patients completed four MP examinations using an identical custom 45 stimuli grid on MP‐3 (NIDEK) and MAIA (CenterVue).



Similar Products

90
Nidek CO microperimetry device nidek mp3
Microperimetry Device Nidek Mp3, supplied by Nidek CO, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/mp+1+microperimeter/pm39672920-166-12-14
Average 90 stars, based on 1 article reviews
microperimetry device nidek mp3 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Nidek CO mp3 device
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Mp3 Device, supplied by Nidek CO, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/mp+3/pmc10921787-139-23-25
Average 90 stars, based on 1 article reviews
mp3 device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sony electronic recording device (mp3 ic recorder)
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Electronic Recording Device (Mp3 Ic Recorder), supplied by Sony, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/electronic+recording+device++mp3+ic+recorder+/pmc09053418-68-7-13
Average 90 stars, based on 1 article reviews
electronic recording device (mp3 ic recorder) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Nidek CO device mp3
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Device Mp3, supplied by Nidek CO, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/mp+3/pm32235121-59-1-3
Average 90 stars, based on 1 article reviews
device mp3 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
apple inc mp3 device
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Mp3 Device, supplied by apple inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/mp3+device/pmc06004489-120-4-6
Average 90 stars, based on 1 article reviews
mp3 device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
iRiver Co Ltd leicester cough monitor iriver ifp-799 mp3 device
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Leicester Cough Monitor Iriver Ifp 799 Mp3 Device, supplied by iRiver Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/portable+hard+disk+player+iriver+140/pm23277522-81-1-4
Average 90 stars, based on 1 article reviews
leicester cough monitor iriver ifp-799 mp3 device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Philips Healthcare mp3 sound recording device philips lfh0662/lfh0865
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Mp3 Sound Recording Device Philips Lfh0662/Lfh0865, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/wearable+digital+audio+recorder+lfh0662/10__1164_slash_rccm__201209___1686oc-48-6-10
Average 90 stars, based on 1 article reviews
mp3 sound recording device philips lfh0662/lfh0865 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
apple inc mp3 ⁄mp4 devices (e.g. ipod
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Mp3 ⁄Mp4 Devices (E.G. Ipod, supplied by apple inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/mp3+%E2%81%84mp4+player/pm20977443-31-33-39
Average 90 stars, based on 1 article reviews
mp3 ⁄mp4 devices (e.g. ipod - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
iRiver Co Ltd control devices iriver 300 series mp3 player
Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry <t>(MP3).</t> B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane
Control Devices Iriver 300 Series Mp3 Player, supplied by iRiver Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mp3+device/control+devices+iriver+300+series+mp3+player/us07755975-512-15-19
Average 90 stars, based on 1 article reviews
control devices iriver 300 series mp3 player - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry (MP3). B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane

Journal: International Journal of Retina and Vitreous

Article Title: Relationship between automated choroidal thickness measurements and retinal sensitivity using microperimetry in patients with myopia and different stages of myopic maculopathy

doi: 10.1186/s40942-024-00541-9

Figure Lengend Snippet: Representative microperimetry, retinal sensitivity (RS), choroidal thickness (CT), and outer retinal layer (ORL) thickness images of control and high myopia (HM) groups. A and D , fundus photographic image with RS assessed via microperimetry (MP3). B and E , fundus photographic image depicting CT in each Early Treatment Diabetic Retinopathy Study (ETDRS) region and the points where the ORL was measured. C and F , B-scan image demonstrating the measurement of ORL thickness, obtained at 9 spots according to ETDRS standards, from the external limiting membrane to the inner edge of RPE/Bruch membrane

Article Snippet: Following the clinical evaluation, patients underwent additional assessments, including axial length measurement using the IOL Master (Carl Zeiss, Jena, Germany), microperimetry with the MP3 device (NIDEK Co. Ltd., Aichi, Japan), and optical coherence tomography (OCT) with the DRI OCT Triton plus ® (TOPCON ® ).

Techniques: Control, Membrane