Review



dna purification kit  (Norgen Biotek)


Bioz Verified Symbol Norgen Biotek is a verified supplier
Bioz Manufacturer Symbol Norgen Biotek manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    Norgen Biotek dna purification kit
    Effect of plasma pre-clearing on <t>DNA</t> recovery and detection of EV markers in PA precipitated material. ( A ) Plasma from six NSCLC donors was either not pre-cleared, or pre-cleared at 3000× g or 17,000× g for 15 min. The post-centrifugation pellet was retained, resuspended in nuclease-free water and DNA was extracted. Peptide affinity (PA) precipitation was performed on equivalent volumes of either non-precleared or pre-cleared plasma and DNA (PA-DNA) was isolated using the Plasma/Serum Cell-Free Circulating DNA <t>Purification</t> Mini Kit (Norgen Biotek). Cell-free DNA (cf-DNA) was obtained from equivalent volumes of plasma using the same DNA isolation kit for comparison ( n = 6; * p < 0.05). A representative overlay of the DNA profiles of ( B ) PA-DNA or ( C ) cf-DNA from plasma (Donor #1) using either no pre-clearing or 3000× g or 17,000× g pre-clearing is shown. ( D ) A representative western blot ( n = 3) of Vn96 PA precipitated material from 1 mL of plasma from donors with benign lung disease or NSCLC is shown. Canonical EV markers CD63, CD9, HSC70, and flotillin-1 were detected using specific antibodies. A vehicle control sample (without Vn96) was included as a negative control (−). In addition, calnexin, apolipoprotein A1 (Apo-A1), and albumin, which are common co-contaminants of EV isolations from plasma, were also detected using specific antibodies. Plasma protein lysate was included as a positive control for non-EV-associated plasma proteins.
    Dna Purification Kit, supplied by Norgen Biotek, used in various techniques. Bioz Stars score: 95/100, based on 88 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/modular+vector+cloning+kit/Plasma%2FSerum+Cell-Free+Circulating+DNA+Purification+Mini+Kit/pmc07730179-217-19-22
    Average 95 stars, based on 88 article reviews
    dna purification kit - by Bioz Stars, 2026-11
    95/100 stars

    Images

    1) Product Images from "Peptide-Affinity Precipitation of Extracellular Vesicles and Cell-Free DNA Improves Sequencing Performance for the Detection of Pathogenic Mutations in Lung Cancer Patient Plasma"

    Article Title: Peptide-Affinity Precipitation of Extracellular Vesicles and Cell-Free DNA Improves Sequencing Performance for the Detection of Pathogenic Mutations in Lung Cancer Patient Plasma

    Journal: International Journal of Molecular Sciences

    doi: 10.3390/ijms21239083

    Effect of plasma pre-clearing on DNA recovery and detection of EV markers in PA precipitated material. ( A ) Plasma from six NSCLC donors was either not pre-cleared, or pre-cleared at 3000× g or 17,000× g for 15 min. The post-centrifugation pellet was retained, resuspended in nuclease-free water and DNA was extracted. Peptide affinity (PA) precipitation was performed on equivalent volumes of either non-precleared or pre-cleared plasma and DNA (PA-DNA) was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Norgen Biotek). Cell-free DNA (cf-DNA) was obtained from equivalent volumes of plasma using the same DNA isolation kit for comparison ( n = 6; * p < 0.05). A representative overlay of the DNA profiles of ( B ) PA-DNA or ( C ) cf-DNA from plasma (Donor #1) using either no pre-clearing or 3000× g or 17,000× g pre-clearing is shown. ( D ) A representative western blot ( n = 3) of Vn96 PA precipitated material from 1 mL of plasma from donors with benign lung disease or NSCLC is shown. Canonical EV markers CD63, CD9, HSC70, and flotillin-1 were detected using specific antibodies. A vehicle control sample (without Vn96) was included as a negative control (−). In addition, calnexin, apolipoprotein A1 (Apo-A1), and albumin, which are common co-contaminants of EV isolations from plasma, were also detected using specific antibodies. Plasma protein lysate was included as a positive control for non-EV-associated plasma proteins.
    Figure Legend Snippet: Effect of plasma pre-clearing on DNA recovery and detection of EV markers in PA precipitated material. ( A ) Plasma from six NSCLC donors was either not pre-cleared, or pre-cleared at 3000× g or 17,000× g for 15 min. The post-centrifugation pellet was retained, resuspended in nuclease-free water and DNA was extracted. Peptide affinity (PA) precipitation was performed on equivalent volumes of either non-precleared or pre-cleared plasma and DNA (PA-DNA) was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Norgen Biotek). Cell-free DNA (cf-DNA) was obtained from equivalent volumes of plasma using the same DNA isolation kit for comparison ( n = 6; * p < 0.05). A representative overlay of the DNA profiles of ( B ) PA-DNA or ( C ) cf-DNA from plasma (Donor #1) using either no pre-clearing or 3000× g or 17,000× g pre-clearing is shown. ( D ) A representative western blot ( n = 3) of Vn96 PA precipitated material from 1 mL of plasma from donors with benign lung disease or NSCLC is shown. Canonical EV markers CD63, CD9, HSC70, and flotillin-1 were detected using specific antibodies. A vehicle control sample (without Vn96) was included as a negative control (−). In addition, calnexin, apolipoprotein A1 (Apo-A1), and albumin, which are common co-contaminants of EV isolations from plasma, were also detected using specific antibodies. Plasma protein lysate was included as a positive control for non-EV-associated plasma proteins.

    Techniques Used: Clinical Proteomics, Centrifugation, Isolation, DNA Purification, DNA Extraction, Comparison, Western Blot, Control, Negative Control, Positive Control

    Related Articles

    Clinical Proteomics:

    Article Title: Assessment of radiotherapy effect and toxicity using tissue-associated DNA methylation markers in cell-free DNA: a study on prostate cancer.
    Article Snippet: .. Determination of relative levels of mtDNA-79 and mtDNA-230 Circulating DNA was extracted from serum samples using the Plasma/Serum Cell-Free Circulating DNA Purification Kit (Norgen Biotek, Canada) according to the manufacturer’s instructions. qPCR was employed to assess mitochondrial DNA (mtDNA) fragments in serum. ..

    Article Title: Bank1 deficiency reshapes the gut microbiota of lupus mice towards an anti-inflammatory composition
    Article Snippet: Fecal microbial DNA was extracted from fecal samples using the QIAamp ® Fast DNA Stool Mini Kit “Pathogen Detection” (QIAcube/QIAGEN). .. Blood microbial DNA was extracted from 200 μl of plasma samples from the set of lupus patients from the PRECISESADS project ( ) using the Norgen Biotek Corp columns for circulating DNA purification kit micro (SKU 55500). .. Both kitoma samples and blood withdrawal skin-puncture-site DNA controls were also obtained with the same Norgen Biotek columns.

    Article Title: Evaluation of Commercially Available Kits for Parallel DNA and microRNA Isolation Suitable for Epigenetic Analyses from Cell-Free Saliva and Salivary Extracellular Vesicles
    Article Snippet: Roche Diagnostics Deutschland GmbH., Mannheim, Germany , RH , Roche High Pure PCR Template Preparation kit , DNA only. .. Norgen-Biotek Corp., Thorold, ON, Canada , NC , Norgen Plasma/Serum Cell Free Circulating DNA , DNA only. .. Norgen-Biotek Corp., Thorold, ON, Canada , NG , Plasma/Serum RNA/DNA Purification Mini Kit , m/miRNA and DNA.

    Article Title: Data‐Driven Feedback Identifies Focused Ultrasound Exposure Regimens for Improved Nanotheranostic Targeting of the Brain
    Article Snippet: .. Serum samples were placed in individual sterile 1.5 mL microcentrifuge tubes, purified using the Plasma/Serum cell‐free DNA Purification kit (Norgen Biotek, Ontario, Canada), and eluted to a final volume of 30 μL. ..

    Article Title: Isolation of extracellular vesicles by precipitation or immobilization using polyethylenimine and polyethylenimine-coated solid supports
    Article Snippet: The liquid was removed and the pellet was resuspended in lysis buffer from the mirVanaTM miRNA isolation kit (Life Technologies) and 0.25% SDS and vortexed for 30 seconds. .. The lysate was then put onto a Norgen Biotek DNA column (Plasma/Serum Cell-free Circulating DNA purification mini kit, Norgen Biotek Corp.) and then centrifuged at 3300 g for 30 seconds to selectively capture DNA. ..

    Article Title: Detection of KRAS, NRAS and BRAF Mutations in Liquid Biopsy from Patients with Colorectal Cancer
    Article Snippet: .. Hemolytic samples were excluded based on visual inspection. cfDNA was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Cat. No. SKU 55100 Norgen Biotek Corp., Thorold, ON, Canada) and its concentration was measured using the QubitTM dsDNA HS Assay Kit (Cat. No. Q33230 Thermo Fisher Scientific, Waltham, MA, USA), which also served as a basic cfDNA integrity metric. ..

    Article Title: Monitoring pembrolizumab response in patients with metastatic non-small cell lung cancer using circulating tumour DNA and circulating tumour cells
    Article Snippet: .. Total cfDNA was extracted from 1–3 mL of plasma collected from 127 samples using the Norgen Plasma/Serum Cell-Free Circulating DNA Purification Midi Kit (Norgen Biotek Corp., ON, Canada) according to the manufacturer’s protocol. cfDNA was eluted in 50 μL nuclease-free water and quantified using a Qubit dsDNA HS-Assay Kit on a Qubit fluorometer 2.0 (Life Technologies, CA, USA). .. The OncomineTM Lung cfDNA Assay (Thermo Fisher Scientific, CA, USA) was used as a selection method to perform NGS in 1–50 ng of total cfDNA isolated at t0 from 43 patients, at t1 from 18 patients, at t2 from 31 patients, and at t3 from 11 patients (n=103), according to the manufacturer’s instructions ( Appendix 1 ).

    Article Title: Methods and materials for treating cancer
    Article Snippet: .. Autoantibody levels were hence calculated by subtracting this number of non-specific IgG counts from total counts in the p53-coated channel. qPCR Serum DNA was extracted with the Plasma/Serum Cell-Free Circulating DNA Purification Micro Kit (Norgen Biotek) according to the manufacturer's instructions. ..

    DNA Purification:

    Article Title: Assessment of radiotherapy effect and toxicity using tissue-associated DNA methylation markers in cell-free DNA: a study on prostate cancer.
    Article Snippet: .. Determination of relative levels of mtDNA-79 and mtDNA-230 Circulating DNA was extracted from serum samples using the Plasma/Serum Cell-Free Circulating DNA Purification Kit (Norgen Biotek, Canada) according to the manufacturer’s instructions. qPCR was employed to assess mitochondrial DNA (mtDNA) fragments in serum. ..

    Article Title: Bank1 deficiency reshapes the gut microbiota of lupus mice towards an anti-inflammatory composition
    Article Snippet: Fecal microbial DNA was extracted from fecal samples using the QIAamp ® Fast DNA Stool Mini Kit “Pathogen Detection” (QIAcube/QIAGEN). .. Blood microbial DNA was extracted from 200 μl of plasma samples from the set of lupus patients from the PRECISESADS project ( ) using the Norgen Biotek Corp columns for circulating DNA purification kit micro (SKU 55500). .. Both kitoma samples and blood withdrawal skin-puncture-site DNA controls were also obtained with the same Norgen Biotek columns.

    Article Title: Data‐Driven Feedback Identifies Focused Ultrasound Exposure Regimens for Improved Nanotheranostic Targeting of the Brain
    Article Snippet: .. Serum samples were placed in individual sterile 1.5 mL microcentrifuge tubes, purified using the Plasma/Serum cell‐free DNA Purification kit (Norgen Biotek, Ontario, Canada), and eluted to a final volume of 30 μL. ..

    Article Title: Isolation of extracellular vesicles by precipitation or immobilization using polyethylenimine and polyethylenimine-coated solid supports
    Article Snippet: The liquid was removed and the pellet was resuspended in lysis buffer from the mirVanaTM miRNA isolation kit (Life Technologies) and 0.25% SDS and vortexed for 30 seconds. .. The lysate was then put onto a Norgen Biotek DNA column (Plasma/Serum Cell-free Circulating DNA purification mini kit, Norgen Biotek Corp.) and then centrifuged at 3300 g for 30 seconds to selectively capture DNA. ..

    Article Title: Detection of KRAS, NRAS and BRAF Mutations in Liquid Biopsy from Patients with Colorectal Cancer
    Article Snippet: .. Hemolytic samples were excluded based on visual inspection. cfDNA was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Cat. No. SKU 55100 Norgen Biotek Corp., Thorold, ON, Canada) and its concentration was measured using the QubitTM dsDNA HS Assay Kit (Cat. No. Q33230 Thermo Fisher Scientific, Waltham, MA, USA), which also served as a basic cfDNA integrity metric. ..

    Article Title: Monitoring pembrolizumab response in patients with metastatic non-small cell lung cancer using circulating tumour DNA and circulating tumour cells
    Article Snippet: .. Total cfDNA was extracted from 1–3 mL of plasma collected from 127 samples using the Norgen Plasma/Serum Cell-Free Circulating DNA Purification Midi Kit (Norgen Biotek Corp., ON, Canada) according to the manufacturer’s protocol. cfDNA was eluted in 50 μL nuclease-free water and quantified using a Qubit dsDNA HS-Assay Kit on a Qubit fluorometer 2.0 (Life Technologies, CA, USA). .. The OncomineTM Lung cfDNA Assay (Thermo Fisher Scientific, CA, USA) was used as a selection method to perform NGS in 1–50 ng of total cfDNA isolated at t0 from 43 patients, at t1 from 18 patients, at t2 from 31 patients, and at t3 from 11 patients (n=103), according to the manufacturer’s instructions ( Appendix 1 ).

    Article Title: Methods and materials for treating cancer
    Article Snippet: .. Autoantibody levels were hence calculated by subtracting this number of non-specific IgG counts from total counts in the p53-coated channel. qPCR Serum DNA was extracted with the Plasma/Serum Cell-Free Circulating DNA Purification Micro Kit (Norgen Biotek) according to the manufacturer's instructions. ..

    Real-time Polymerase Chain Reaction:

    Article Title: Assessment of radiotherapy effect and toxicity using tissue-associated DNA methylation markers in cell-free DNA: a study on prostate cancer.
    Article Snippet: .. Determination of relative levels of mtDNA-79 and mtDNA-230 Circulating DNA was extracted from serum samples using the Plasma/Serum Cell-Free Circulating DNA Purification Kit (Norgen Biotek, Canada) according to the manufacturer’s instructions. qPCR was employed to assess mitochondrial DNA (mtDNA) fragments in serum. ..

    Article Title: Methods and materials for treating cancer
    Article Snippet: .. Autoantibody levels were hence calculated by subtracting this number of non-specific IgG counts from total counts in the p53-coated channel. qPCR Serum DNA was extracted with the Plasma/Serum Cell-Free Circulating DNA Purification Micro Kit (Norgen Biotek) according to the manufacturer's instructions. ..

    Sterility:

    Article Title: Data‐Driven Feedback Identifies Focused Ultrasound Exposure Regimens for Improved Nanotheranostic Targeting of the Brain
    Article Snippet: .. Serum samples were placed in individual sterile 1.5 mL microcentrifuge tubes, purified using the Plasma/Serum cell‐free DNA Purification kit (Norgen Biotek, Ontario, Canada), and eluted to a final volume of 30 μL. ..

    Purification:

    Article Title: Data‐Driven Feedback Identifies Focused Ultrasound Exposure Regimens for Improved Nanotheranostic Targeting of the Brain
    Article Snippet: .. Serum samples were placed in individual sterile 1.5 mL microcentrifuge tubes, purified using the Plasma/Serum cell‐free DNA Purification kit (Norgen Biotek, Ontario, Canada), and eluted to a final volume of 30 μL. ..

    Process/Product Development:

    Article Title: Detection of KRAS, NRAS and BRAF Mutations in Liquid Biopsy from Patients with Colorectal Cancer
    Article Snippet: .. Hemolytic samples were excluded based on visual inspection. cfDNA was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Cat. No. SKU 55100 Norgen Biotek Corp., Thorold, ON, Canada) and its concentration was measured using the QubitTM dsDNA HS Assay Kit (Cat. No. Q33230 Thermo Fisher Scientific, Waltham, MA, USA), which also served as a basic cfDNA integrity metric. ..

    Isolation:

    Article Title: Detection of KRAS, NRAS and BRAF Mutations in Liquid Biopsy from Patients with Colorectal Cancer
    Article Snippet: .. Hemolytic samples were excluded based on visual inspection. cfDNA was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Cat. No. SKU 55100 Norgen Biotek Corp., Thorold, ON, Canada) and its concentration was measured using the QubitTM dsDNA HS Assay Kit (Cat. No. Q33230 Thermo Fisher Scientific, Waltham, MA, USA), which also served as a basic cfDNA integrity metric. ..

    Concentration Assay:

    Article Title: Detection of KRAS, NRAS and BRAF Mutations in Liquid Biopsy from Patients with Colorectal Cancer
    Article Snippet: .. Hemolytic samples were excluded based on visual inspection. cfDNA was isolated using the Plasma/Serum Cell-Free Circulating DNA Purification Mini Kit (Cat. No. SKU 55100 Norgen Biotek Corp., Thorold, ON, Canada) and its concentration was measured using the QubitTM dsDNA HS Assay Kit (Cat. No. Q33230 Thermo Fisher Scientific, Waltham, MA, USA), which also served as a basic cfDNA integrity metric. ..



    Similar Products

    93
    Addgene inc modular cloning vectors goldenpics
    Modular Cloning Vectors Goldenpics, supplied by Addgene inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/modular+vector+cloning+kit/GoldenPiCS+Kit+(Kit+%231000000133)/pmc09354023-65-1-7
    Average 93 stars, based on 1 article reviews
    modular cloning vectors goldenpics - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    93
    Addgene inc modular vector cloning kit
    Modular Vector Cloning Kit, supplied by Addgene inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/modular+vector+cloning+kit/MoClo-YTK+(Kit+%231000000061)/pm35044755-56-10-15
    Average 93 stars, based on 1 article reviews
    modular vector cloning kit - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    Image Search Results