Review




Structured Review

Varian Medical mobius software
Mobius Software, supplied by Varian Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/mobius3d/pmc12704200-83-11-13
Average 86 stars, based on 1 article reviews
mobius software - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

other:

Article Title: Simulated online adaptive radiotherapy on C-arm linacs: Integrating high resolution cone-beam CT into abdominal stereotactic body radiation therapy.
Article Snippet: Patient-specific IMRT quality assurance (QA) using Mobius3D (Varian Medical Systems, California) and physics plan check were also performed to ensure the plan quality.

Article Title: Simulated online adaptive radiotherapy on C‐arm linacs: Integrating high resolution cone‐beam CT into abdominal stereotactic body radiation therapy
Article Snippet: Patient‐specific IMRT quality assurance (QA) using Mobius3D (Varian Medical Systems, California) and physics plan check were also performed to ensure the plan quality.

Article Title: Prospective controlled study comparing patient-reported outcomes after daily online adaptive radiotherapy or conventional IGRT in patients with prostate cancer
Article Snippet: For on couch plan quality assurance during adaptive sessions an independent secondary dose calculation in Mobius3D (Varian Medical Systems) was used for 3D gamma analysis with same criteria as for initially measured plans.

Article Title: First evaluation of in-patient dose calculation accuracy on a C-arm Linear Accelerator with advanced Cone-Beam computed tomography (CBCT) imaging
Article Snippet: For example, when using a 3%/3mm global criteria greater than 90%, two separate reports by Kim et al. reported an average GPR of 93.2% when comparing Raystation with Mobius3D (Varian Medical Systems, Palo Alto, CA, USA) and a 5.9% GPR failing rate with MobiusFx., When evaluating with RadCalc (LifeLine Software Inc., Tyler, Tx, USA), Mastella et al., reported stronger GPR with an average of 98.5% with slightly more stringent evaluation criteria of 3%/2mm using a 10% threshold.

Software:

Article Title: Implementing log file‐based patient‐specific QA for VMAT plans: A comparative study of MobiusFX and measurement‐based approaches
Article Snippet: .. Currently, log file‐based PSQA is commercially available as part of the Mobius3D (Varian Medical Systems Inc., Palo Alto, CA, USA), a software package designed for computational‐based PSQA. ..

Article Title: A survey of practice patterns for patient-specific quality assurance on behalf of the ESTRO dosimetry & quality assurance focus group
Article Snippet: .. They can include verification of the planned dose calculation using independent software tools (for example Mobius3D (Varian, USA), DoseCheck TM (Sun Nuclear, USA) or SciMoCa TM (IBA, Germany)), measurement-based approaches for the verification of the delivered dose in specialised phantoms with embedded detector arrays (like Octavius (PTW, Germany), ArcCHECK (Sun Nuclear, USA), Delta4 (Scandidos, Sweden) or MatriXX (IBA, Germany)), or in geometric and/or anthropomorphic phantoms with point detectors and/or radiochromic films (such as Gafchromic TM EBT4 (Ashland, USA) or OrthoChromic (Oncology Imaging Systems, UK)), or verification of the fluence or dose delivered on the electronic portal imager (for example by using the solutions of Portal Dosimetry (Varian, USA), Epiqa TM (Epidos, Slovak Republic), PerFRACTION − Fraction 0 (Sun Nuclear, USA)). .. Software tools which analyse and/or compute dose using the information from treatment log files (for example myQA iON (IBA, Germany) or LINACwatch (Qualiformed, France)) and or transmission fluence captured on the EPID, namely transit in-vivo dosimetry approaches (e.g PerFRACTION TM (Sun Nuclear, USA) or VeriQA (PTW, Germany)) can also be included.

Imaging:

Article Title: A survey of practice patterns for patient-specific quality assurance on behalf of the ESTRO dosimetry & quality assurance focus group
Article Snippet: .. They can include verification of the planned dose calculation using independent software tools (for example Mobius3D (Varian, USA), DoseCheck TM (Sun Nuclear, USA) or SciMoCa TM (IBA, Germany)), measurement-based approaches for the verification of the delivered dose in specialised phantoms with embedded detector arrays (like Octavius (PTW, Germany), ArcCHECK (Sun Nuclear, USA), Delta4 (Scandidos, Sweden) or MatriXX (IBA, Germany)), or in geometric and/or anthropomorphic phantoms with point detectors and/or radiochromic films (such as Gafchromic TM EBT4 (Ashland, USA) or OrthoChromic (Oncology Imaging Systems, UK)), or verification of the fluence or dose delivered on the electronic portal imager (for example by using the solutions of Portal Dosimetry (Varian, USA), Epiqa TM (Epidos, Slovak Republic), PerFRACTION − Fraction 0 (Sun Nuclear, USA)). .. Software tools which analyse and/or compute dose using the information from treatment log files (for example myQA iON (IBA, Germany) or LINACwatch (Qualiformed, France)) and or transmission fluence captured on the EPID, namely transit in-vivo dosimetry approaches (e.g PerFRACTION TM (Sun Nuclear, USA) or VeriQA (PTW, Germany)) can also be included.



Similar Products

90
Alpha MED Scientific mobius software
Mobius Software, supplied by Alpha MED Scientific, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/mobius+software/us12364776-296-4-6
Average 90 stars, based on 1 article reviews
mobius software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
Varian Medical secondary dose calculation software mobius
Secondary Dose Calculation Software Mobius, supplied by Varian Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/acuros+algorithm+xb/pmc13172267-85-7-12
Average 86 stars, based on 1 article reviews
secondary dose calculation software mobius - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Varian Medical mobius software
Mobius Software, supplied by Varian Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/mobius3d/pmc12704200-83-11-13
Average 86 stars, based on 1 article reviews
mobius software - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Varian Medical mobius 3d quality assurance qa software v4
The applied workflow during an online-adaptive treatment session: A planning computed tomography (CT) scan is acquired prior to treatment and serves as the reference for initial planning ( 1 ). A daily cone beam CT (CBCT 1) is obtained at the beginning of each treatment session ( 2 ). Daily anatomical variations are delineated on this image and used for online-adaptive treatment planning. An independent verification software <t>(Mobius</t> <t>3D</t> <t>v4,</t> Varian Medical Systems, Palo Alto, CA, USA) is employed to validate the adaptive plans prior to treatment ( 3 ). A second CBCT 2 ( 4 ) is used to account for intra-fraction motion during the planning period, and the online-adaptive treatment fraction is delivered immediately afterward ( 5 ).
Mobius 3d Quality Assurance Qa Software V4, supplied by Varian Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/mobius3d/pmc12566251-206-13-20
Average 86 stars, based on 1 article reviews
mobius 3d quality assurance qa software v4 - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Varian Medical independent dose-calculation qa software mobius
The applied workflow during an online-adaptive treatment session: A planning computed tomography (CT) scan is acquired prior to treatment and serves as the reference for initial planning ( 1 ). A daily cone beam CT (CBCT 1) is obtained at the beginning of each treatment session ( 2 ). Daily anatomical variations are delineated on this image and used for online-adaptive treatment planning. An independent verification software <t>(Mobius</t> <t>3D</t> <t>v4,</t> Varian Medical Systems, Palo Alto, CA, USA) is employed to validate the adaptive plans prior to treatment ( 3 ). A second CBCT 2 ( 4 ) is used to account for intra-fraction motion during the planning period, and the online-adaptive treatment fraction is delivered immediately afterward ( 5 ).
Independent Dose Calculation Qa Software Mobius, supplied by Varian Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/mobius+software/pmc12210003-116-10-11
Average 90 stars, based on 1 article reviews
independent dose-calculation qa software mobius - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Mobius Medical logfile qa software mobius fx
The applied workflow during an online-adaptive treatment session: A planning computed tomography (CT) scan is acquired prior to treatment and serves as the reference for initial planning ( 1 ). A daily cone beam CT (CBCT 1) is obtained at the beginning of each treatment session ( 2 ). Daily anatomical variations are delineated on this image and used for online-adaptive treatment planning. An independent verification software <t>(Mobius</t> <t>3D</t> <t>v4,</t> Varian Medical Systems, Palo Alto, CA, USA) is employed to validate the adaptive plans prior to treatment ( 3 ). A second CBCT 2 ( 4 ) is used to account for intra-fraction motion during the planning period, and the online-adaptive treatment fraction is delivered immediately afterward ( 5 ).
Logfile Qa Software Mobius Fx, supplied by Mobius Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mobius+software/logfile+qa+software+mobius+fx/pmc12256692-81-24-29
Average 90 stars, based on 1 article reviews
logfile qa software mobius fx - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


The applied workflow during an online-adaptive treatment session: A planning computed tomography (CT) scan is acquired prior to treatment and serves as the reference for initial planning ( 1 ). A daily cone beam CT (CBCT 1) is obtained at the beginning of each treatment session ( 2 ). Daily anatomical variations are delineated on this image and used for online-adaptive treatment planning. An independent verification software (Mobius 3D v4, Varian Medical Systems, Palo Alto, CA, USA) is employed to validate the adaptive plans prior to treatment ( 3 ). A second CBCT 2 ( 4 ) is used to account for intra-fraction motion during the planning period, and the online-adaptive treatment fraction is delivered immediately afterward ( 5 ).

Journal: Medicina

Article Title: CBCT-Based Online Adaptive, Ultra-Hypofractionated Radiotherapy for Prostate Cancer: First Clinical Experiences

doi: 10.3390/medicina61101839

Figure Lengend Snippet: The applied workflow during an online-adaptive treatment session: A planning computed tomography (CT) scan is acquired prior to treatment and serves as the reference for initial planning ( 1 ). A daily cone beam CT (CBCT 1) is obtained at the beginning of each treatment session ( 2 ). Daily anatomical variations are delineated on this image and used for online-adaptive treatment planning. An independent verification software (Mobius 3D v4, Varian Medical Systems, Palo Alto, CA, USA) is employed to validate the adaptive plans prior to treatment ( 3 ). A second CBCT 2 ( 4 ) is used to account for intra-fraction motion during the planning period, and the online-adaptive treatment fraction is delivered immediately afterward ( 5 ).

Article Snippet: An independent verification of the dose distribution was performed using simulation in the Mobius 3D quality assurance (QA) software v4 (Varian Medical Systems, Palo Alto, CA, USA) via gamma analysis (3%/3 mm criteria).

Techniques: Computed Tomography, Software