Review



genepix  (Danaher Inc)


Bioz Verified Symbol Danaher Inc is a verified supplier
Bioz Manufacturer Symbol Danaher Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    Danaher Inc genepix
    Genepix, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 461 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/GenePix+Microarray+Systems/pmc02847482-176-7-8
    Average 94 stars, based on 461 article reviews
    genepix - by Bioz Stars, 2026-10
    94/100 stars

    Images

    Related Articles

    Microarray:

    Article Title: Unraveling the role of HDAC3 as an immunotherapy prognostic biomarker and therapeutic target in advanced non-small cell lung cancer
    Article Snippet: The microarray was retrieved from − 80 °C storage and blocked with bovine serum albumin (BSA, 9048-46-8, Sigma) for 1.5 h. Following the blocking step, the microarray was incubated with plasma samples at a 1:1000 dilution for 1 h. After washing with 0.1% phosphate-buffered saline-Tween 20, the plates were incubated with Alexa Fluor 647 goat anti-human IgG (109-605-003, Jackson) diluted in 5% BSA. .. The microarray was then scanned using a GenePix 4300 A microarray scanner (141095, Molecular Devices) with a 635 nm excitation laser. .. Signal intensities of IgG for each protein were quantified using GenePix Pro v.6.0 software (Molecular Devices).

    Article Title: Maackia amurensis seed lectin structure and sequence comparison with other M. amurensis lectins
    Article Snippet: MASL, MAL2, and MAA lectins were biotinylated and hybridized (30 ug/ml) to Glycan Array 300 arrays (RayBiotech) which contain 300 triplicated synthetic glycans along with biotinylated protein positive controls and empty negative controls. .. Lectin binding was detected by incubation with Cy5 equivalent dye-conjugated streptavidin and visualized with a GenePix 4000B microarray laser scanner equipped with GenePix Pro version 7.2 software ( https://genepix-pro.software.informer.com/7.2 ) (Molecular Devices). .. Mean signal intensities were normalized to positive controls and analyzed using RayBio GA-Glycan-300-SW Analysis software ( https://www.raybiotech.com/glycan-array-300-ga-glycan-300 ) (RayBiotech).

    Article Title: DNPH1 exerts context-dependent tumor-promoting and -repressing functions during melanoma development.
    Article Snippet: These processed protein samples were then used to challenge Phospho Explorer antibody arrays (Full Moon Biosystems, PEX100). .. For detection, Alexa Fluor 555 streptavidin (Invitrogen, S-32355) was employed and the arrays were analyzed with a microarray scanner (Molecular Devices, GenePix 4100A). ..

    Article Title: Biomarkers and immunogenic compositions for filarial parasites
    Article Snippet: Chips were air dried by centrifugation at 500×g for 10 min, stored in a light proof desiccator for at least 2 hr and scanned on a GENEPIX® 4300 with Autoloader (Molecular Devices) using the 635 nm laser. .. Resulting 16-bit TIFF images were quantified using GENEPIX® Pro Microarray Analysis Software (Molecular Devices) and a GENEPIX® Array List (GAL) file. ..

    Article Title: Supporting Information _ Lee and Fan _ Yale
    Article Snippet: .. An Axon Genepix microarray scanner 4000B (Molecular Devices, USA) was used to image DRAQ5-stained cells (emitting 635 nm) on the STRQNW arrays. ..

    other:

    Article Title: Development of Lamprey-derived Antibodies Against Human Blood Group Antigens.
    Article Snippet: A major challenge in the glycosciences is the scarcity of sensitive and specific glycanbinding reagents, such as monoclonal antibodies, for detecting and isolating glycans.. Here we report the development and characterization of new monoclonal antibodies (mAbs) that bind carbohydrate-based red blood cell (RBC) antigens including the ABO(H) antigens.. This approach exploits the immune system of the sea lamprey (Petromyzon marinus), which strongly responds to human glycans to enable the generation of high affinity antibodies.

    Article Title: Development of lamprey-derived antibodies against human blood group antigens
    Article Snippet: The scans were analyzed using GenePix (Molecular Devices) software and GLAD (GLycan Array Dashboard) software ( ).

    Binding Assay:

    Article Title: Maackia amurensis seed lectin structure and sequence comparison with other M. amurensis lectins
    Article Snippet: MASL, MAL2, and MAA lectins were biotinylated and hybridized (30 ug/ml) to Glycan Array 300 arrays (RayBiotech) which contain 300 triplicated synthetic glycans along with biotinylated protein positive controls and empty negative controls. .. Lectin binding was detected by incubation with Cy5 equivalent dye-conjugated streptavidin and visualized with a GenePix 4000B microarray laser scanner equipped with GenePix Pro version 7.2 software ( https://genepix-pro.software.informer.com/7.2 ) (Molecular Devices). .. Mean signal intensities were normalized to positive controls and analyzed using RayBio GA-Glycan-300-SW Analysis software ( https://www.raybiotech.com/glycan-array-300-ga-glycan-300 ) (RayBiotech).

    Incubation:

    Article Title: Maackia amurensis seed lectin structure and sequence comparison with other M. amurensis lectins
    Article Snippet: MASL, MAL2, and MAA lectins were biotinylated and hybridized (30 ug/ml) to Glycan Array 300 arrays (RayBiotech) which contain 300 triplicated synthetic glycans along with biotinylated protein positive controls and empty negative controls. .. Lectin binding was detected by incubation with Cy5 equivalent dye-conjugated streptavidin and visualized with a GenePix 4000B microarray laser scanner equipped with GenePix Pro version 7.2 software ( https://genepix-pro.software.informer.com/7.2 ) (Molecular Devices). .. Mean signal intensities were normalized to positive controls and analyzed using RayBio GA-Glycan-300-SW Analysis software ( https://www.raybiotech.com/glycan-array-300-ga-glycan-300 ) (RayBiotech).

    Software:

    Article Title: Maackia amurensis seed lectin structure and sequence comparison with other M. amurensis lectins
    Article Snippet: MASL, MAL2, and MAA lectins were biotinylated and hybridized (30 ug/ml) to Glycan Array 300 arrays (RayBiotech) which contain 300 triplicated synthetic glycans along with biotinylated protein positive controls and empty negative controls. .. Lectin binding was detected by incubation with Cy5 equivalent dye-conjugated streptavidin and visualized with a GenePix 4000B microarray laser scanner equipped with GenePix Pro version 7.2 software ( https://genepix-pro.software.informer.com/7.2 ) (Molecular Devices). .. Mean signal intensities were normalized to positive controls and analyzed using RayBio GA-Glycan-300-SW Analysis software ( https://www.raybiotech.com/glycan-array-300-ga-glycan-300 ) (RayBiotech).

    Article Title: Biomarkers and immunogenic compositions for filarial parasites
    Article Snippet: Chips were air dried by centrifugation at 500×g for 10 min, stored in a light proof desiccator for at least 2 hr and scanned on a GENEPIX® 4300 with Autoloader (Molecular Devices) using the 635 nm laser. .. Resulting 16-bit TIFF images were quantified using GENEPIX® Pro Microarray Analysis Software (Molecular Devices) and a GENEPIX® Array List (GAL) file. ..

    Fluorescence:

    Article Title: An African swine fever virus-specific antibody reactome reveals antigens as potential candidates for vaccine development
    Article Snippet: After being washed three times and air-dried through brief centrifugation, the slides were scanned using a Genepix 4200A scanner (Molecular Devices, CA, USA). .. The median foreground and background fluorescence intensities were measured for each spot on the protein microarrays using GenePix Pro 6.0 (Molecular Devices, CA, USA). ..



    Similar Products

    90
    CapitalBio Corporation luxscan 10k-b microarray scanner
    Luxscan 10k B Microarray Scanner, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/luxscan+10+k+microarray+scanner/nct06133946-1-30-34
    Average 90 stars, based on 1 article reviews
    luxscan 10k-b microarray scanner - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Innopsys Inc the innoscan 300 microarray scanner
    The Innoscan 300 Microarray Scanner, supplied by Innopsys Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/innoscan+300+microarray+scanner/nct06243497-6-1-6
    Average 90 stars, based on 1 article reviews
    the innoscan 300 microarray scanner - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    96
    Illumina Inc illumina methylationepic beadchip microarray
    Illumina Methylationepic Beadchip Microarray, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/Infinium+MethylationEPIC+BeadChip+Kit/pm42883772-749-4-4
    Average 96 stars, based on 1 article reviews
    illumina methylationepic beadchip microarray - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    95
    SCIENION wheat allergen microarray assay
    Wheat Allergen Microarray Assay, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/sciFLEXARRAYER+S12/pm42884101-259-1-13
    Average 95 stars, based on 1 article reviews
    wheat allergen microarray assay - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    94
    Illumina Inc genochip 2 0 microarray
    Genochip 2 0 Microarray, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/iSelect+HD+Custom+BeadChip/pm42828432-377-29-32
    Average 94 stars, based on 1 article reviews
    genochip 2 0 microarray - by Bioz Stars, 2026-10
    94/100 stars
      Buy from Supplier

    99
    Olympus issue microarray scanner
    Issue Microarray Scanner, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/VS120+Virtual+Slide+Microscope+Virtual+Slide+Microscopy/pm42814517-283-18-22
    Average 99 stars, based on 1 article reviews
    issue microarray scanner - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    94
    Danaher Inc microarray scanner
    Microarray Scanner, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/GenePix+Microarray+Systems/pm42772593-192-17-19
    Average 94 stars, based on 1 article reviews
    microarray scanner - by Bioz Stars, 2026-10
    94/100 stars
      Buy from Supplier

    94
    RayBiotech inc cytokine protein microarray analysis cytokine protein levels
    Cytokine Protein Microarray Analysis Cytokine Protein Levels, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/Mouse+Cytokine+Array+GS1000/pm42680000-156-0-11
    Average 94 stars, based on 1 article reviews
    cytokine protein microarray analysis cytokine protein levels - by Bioz Stars, 2026-10
    94/100 stars
      Buy from Supplier

    94
    RayBiotech inc jo urn al pr e p roo f 12 apoptosis protein microarray analysis apoptosis signaling
    Jo Urn Al Pr E P Roo F 12 Apoptosis Protein Microarray Analysis Apoptosis Signaling, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/Mouse+Apoptosis+Signaling+Pathway+Array+C1/pm42680000-150-0-18
    Average 94 stars, based on 1 article reviews
    jo urn al pr e p roo f 12 apoptosis protein microarray analysis apoptosis signaling - by Bioz Stars, 2026-10
    94/100 stars
      Buy from Supplier

    95
    SCIENION non contact inkjet microarray printer
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    Non Contact Inkjet Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microarrays/sciFLEXARRAYER+S12/pmc13380757-243-19-23
    Average 95 stars, based on 1 article reviews
    non contact inkjet microarray printer - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    Image Search Results


    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

    Journal: iScience

    Article Title: A rapid point-of-care test for vancomycin monitoring at the clinical bedside

    doi: 10.1016/j.isci.2026.116064

    Figure Lengend Snippet: The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

    Article Snippet: Following polymerization, D4 assays were fabricated using non-contact inkjet printing methods as described elsewhere., VANC-BSA was printed using a non-contact inkjet microarray printer (Scienion, sciFLEXARRAYER Type S12).

    Techniques: Polymer, Labeling, Dissolution, Diffusion-based Assay, Fluorescence, Concentration Assay