Review




Structured Review

Full Moon BioSystems fmb microarray scanner calibration slides
Fmb Microarray Scanner Calibration Slides, supplied by Full Moon BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+scanner+calibration+slide/microarray+scanner+calibration+slide/us08636954-18-4-0
Average 90 stars, based on 1 article reviews
fmb microarray scanner calibration slides - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Microarray:

Article Title: Calibration slide for fluorescence detection instruments and process of preparation
Article Snippet: .. Full Moon Biosystems produces similar calibration slide—FMB Microarray Scanner Calibration Slides. ..

Article Title: Two-laser, large-field hyperspectral microarray scanner for the analysis of multicolor microarrays.
Article Snippet: We describe the development and operation of a two-laser, large-field hyperspectral scanner for analysis of multicolor genotyping microarrays.. In contrast to confocal microarray scanners, in which wavelength selectivity is obtained by positioning band-pass filters in front of a photomultiplier detector, hyperspectral microarray scanners collect the complete visible emission spectrum from the labeled microarrays.. Hyperspectral scanning permits discrimination of multiple spectrally overlapping fluorescent labels with minimal use of optical filters, thus offering important advantages over standard filter-based multicolor microarray scanners.

Article Title: Microarray scanner calibration curves: characteristics and implications
Article Snippet: .. Microarray scanner calibration slide The microarray scanner calibration slide from Full Moon BioSystems Inc. (Sunnyvale, California, USA) has been developed for performing quantitative evaluations of microarray scanners in terms of dynamic range, limit of detection, uniformity of microarray scanners, channel-tochannel cross-talk, and laser stability. ..

Article Title: Microarray scanner calibration curves: characteristics and implications
Article Snippet: .. The microarray scanner calibration slide from Full Moon BioSystems Inc. (Sunnyvale, California, USA) has been developed for performing quantitative evaluations of microarray scanners in terms of dynamic range, limit of detection, uniformity of microarray scanners, channel-to-channel cross-talk, and laser stability. ..

Article Title: Microarray scanner calibration curves: characteristics and implications
Article Snippet: .. Methods Microarray scanner calibration slide The microarray scanner calibration slide from Full Moon BioSystems Inc. (Sunnyvale, California, USA) has been developed for performing quantitative evaluations of microarray scanners in terms of dynamic range, limit of detection, uniformity of microarray scanners, channel-tochannel cross-talk, and laser stability. ..

Article Title: Beyond Affymetrix arrays: expanding the set of known hybridization isotherms and observing pre-wash signal intensities
Article Snippet: .. The VersArray ChipReader 10 μm System scanner (Bio-Rad Laboratories, USA) was calibrated using a microarray scanner calibration slide from Full Moon Biosystems, and optimal PMT settings were chosen for scanning Erie and VWR microarrays. .. Images were stored as 16-bit TIFF files and processed using ImaGene software (BioDiscovery, Inc., USA).



Similar Products

90
Full Moon BioSystems fmb microarray scanner calibration slides
Fmb Microarray Scanner Calibration Slides, supplied by Full Moon BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+scanner+calibration+slide/microarray+scanner+calibration+slide/us08636954-18-4-0
Average 90 stars, based on 1 article reviews
fmb microarray scanner calibration slides - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Full Moon BioSystems microarray scanner calibration slide
Hybridization isotherms obtained on two different <t>microarray</t> platforms for rRNA target and Probe 596. Left and middle panels represent replicated Erie microarrays while the right panels represent VWR microarrays. Different rows represent distinct spotted probe concentrations. Each data point is the mean of at least six replicated spots. Error is measured as standard deviation. Isotherms from Erie microarrays are linear (but plotted on a log scale) while VWR microarrays followed the Langmuir model.
Microarray Scanner Calibration Slide, supplied by Full Moon BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+scanner+calibration+slide/microarray+scanner+calibration+slide/pmc02836560-131-14-19
Average 90 stars, based on 1 article reviews
microarray scanner calibration slide - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Hybridization isotherms obtained on two different microarray platforms for rRNA target and Probe 596. Left and middle panels represent replicated Erie microarrays while the right panels represent VWR microarrays. Different rows represent distinct spotted probe concentrations. Each data point is the mean of at least six replicated spots. Error is measured as standard deviation. Isotherms from Erie microarrays are linear (but plotted on a log scale) while VWR microarrays followed the Langmuir model.

Journal: Nucleic Acids Research

Article Title: Beyond Affymetrix arrays: expanding the set of known hybridization isotherms and observing pre-wash signal intensities

doi: 10.1093/nar/gkp1122

Figure Lengend Snippet: Hybridization isotherms obtained on two different microarray platforms for rRNA target and Probe 596. Left and middle panels represent replicated Erie microarrays while the right panels represent VWR microarrays. Different rows represent distinct spotted probe concentrations. Each data point is the mean of at least six replicated spots. Error is measured as standard deviation. Isotherms from Erie microarrays are linear (but plotted on a log scale) while VWR microarrays followed the Langmuir model.

Article Snippet: The VersArray ChipReader 10 μm System scanner (Bio-Rad Laboratories, USA) was calibrated using a microarray scanner calibration slide from Full Moon Biosystems, and optimal PMT settings were chosen for scanning Erie and VWR microarrays.

Techniques: Hybridization, Microarray, Standard Deviation

K versus spotted probe concentration for the pure rRNA target and the same probes ( n = 95) but different microarray platforms. Top and middle panels, replicated Erie microarrays; Bottom panel, VWR microarray. Red line shows the general trend based on the mean.

Journal: Nucleic Acids Research

Article Title: Beyond Affymetrix arrays: expanding the set of known hybridization isotherms and observing pre-wash signal intensities

doi: 10.1093/nar/gkp1122

Figure Lengend Snippet: K versus spotted probe concentration for the pure rRNA target and the same probes ( n = 95) but different microarray platforms. Top and middle panels, replicated Erie microarrays; Bottom panel, VWR microarray. Red line shows the general trend based on the mean.

Article Snippet: The VersArray ChipReader 10 μm System scanner (Bio-Rad Laboratories, USA) was calibrated using a microarray scanner calibration slide from Full Moon Biosystems, and optimal PMT settings were chosen for scanning Erie and VWR microarrays.

Techniques: Concentration Assay, Microarray

The effect of successive stringent washes on probe fluorescent densities recorded at equilibrium. Samples were hybridized for 4 h (Panels in rows A and B) or 24 h (Panels C and D in rows) with active mixing and were either pure rRNA (Panels in rows A and C) or rRNA mixed with unlabeled tRNA (Panels in rows B and D). These results are based on at least two independent microarray experiments. Note that the number of points is not the same for different washes because converting signal intensity to fluorescent density sometimes generated numbers that were nonphysical.

Journal: Nucleic Acids Research

Article Title: Beyond Affymetrix arrays: expanding the set of known hybridization isotherms and observing pre-wash signal intensities

doi: 10.1093/nar/gkp1122

Figure Lengend Snippet: The effect of successive stringent washes on probe fluorescent densities recorded at equilibrium. Samples were hybridized for 4 h (Panels in rows A and B) or 24 h (Panels C and D in rows) with active mixing and were either pure rRNA (Panels in rows A and C) or rRNA mixed with unlabeled tRNA (Panels in rows B and D). These results are based on at least two independent microarray experiments. Note that the number of points is not the same for different washes because converting signal intensity to fluorescent density sometimes generated numbers that were nonphysical.

Article Snippet: The VersArray ChipReader 10 μm System scanner (Bio-Rad Laboratories, USA) was calibrated using a microarray scanner calibration slide from Full Moon Biosystems, and optimal PMT settings were chosen for scanning Erie and VWR microarrays.

Techniques: Microarray, Generated