Review




Structured Review

Corning Life Sciences microarray hybridization chamber
Plot of gene expression of sorted/unsorted cells . Plot of one-sample T-test p-values with fold-change in gene expression for all ORFs in <t>microarray</t> study I. Vertical lines show the cutoff of fold-change of 2 (Log 2 ratio of ± 1), while the horizontal line shows the cutoff of p-value 0.05. Genes located in the left-bottom corner (Log 2 ratio <-1 and p-value <0.05) and in the right-bottom corner (Log 2 ratio >1 and p-value <0.05) were considered to have their expressions changed due to dispersion/homogenization and IMS (immuno-magnetic separation) cell sorting. A total of ten genes were selected using these criteria, eight of which also differentially expressed in the independent microarray study II.
Microarray Hybridization Chamber, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/pmc03076228-154-4-8?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
microarray hybridization chamber - by Bioz Stars, 2026-07
90/100 stars

Images

1) Product Images from "Separation of the bacterial species, Escherichia coli , from mixed-species microbial communities for transcriptome analysis"

Article Title: Separation of the bacterial species, Escherichia coli , from mixed-species microbial communities for transcriptome analysis

Journal: BMC Microbiology

doi: 10.1186/1471-2180-11-59

Plot of gene expression of sorted/unsorted cells . Plot of one-sample T-test p-values with fold-change in gene expression for all ORFs in microarray study I. Vertical lines show the cutoff of fold-change of 2 (Log 2 ratio of ± 1), while the horizontal line shows the cutoff of p-value 0.05. Genes located in the left-bottom corner (Log 2 ratio <-1 and p-value <0.05) and in the right-bottom corner (Log 2 ratio >1 and p-value <0.05) were considered to have their expressions changed due to dispersion/homogenization and IMS (immuno-magnetic separation) cell sorting. A total of ten genes were selected using these criteria, eight of which also differentially expressed in the independent microarray study II.
Figure Legend Snippet: Plot of gene expression of sorted/unsorted cells . Plot of one-sample T-test p-values with fold-change in gene expression for all ORFs in microarray study I. Vertical lines show the cutoff of fold-change of 2 (Log 2 ratio of ± 1), while the horizontal line shows the cutoff of p-value 0.05. Genes located in the left-bottom corner (Log 2 ratio <-1 and p-value <0.05) and in the right-bottom corner (Log 2 ratio >1 and p-value <0.05) were considered to have their expressions changed due to dispersion/homogenization and IMS (immuno-magnetic separation) cell sorting. A total of ten genes were selected using these criteria, eight of which also differentially expressed in the independent microarray study II.

Techniques Used: Expressing, Microarray, Homogenization, FACS

Genes identified as differentially expressed # between IMS sorted E. coli cells versus unsorted E. coli cells* by the method of cDNA  microarray  and their differential expression confirmed with another method of qPCR
Figure Legend Snippet: Genes identified as differentially expressed # between IMS sorted E. coli cells versus unsorted E. coli cells* by the method of cDNA microarray and their differential expression confirmed with another method of qPCR

Techniques Used: Microarray, Expressing



Similar Products

90
Camlab Ltd microarray hybridization chamber
Microarray Hybridization Chamber, supplied by Camlab Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/pm40561749-99-7-10?v=Camlab+Ltd
Average 90 stars, based on 1 article reviews
microarray hybridization chamber - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Agilent technologies microarray hybridisation chamber user guide
Microarray Hybridisation Chamber User Guide, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/us11976284-506-7-12?v=Agilent+technologies
Average 90 stars, based on 1 article reviews
microarray hybridisation chamber user guide - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Sarstedt four-chamber microarray incubation tray
Four Chamber Microarray Incubation Tray, supplied by Sarstedt, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/bio_rxiv__2024__01__25__576086-198-45-49?v=Sarstedt
Average 90 stars, based on 1 article reviews
four-chamber microarray incubation tray - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Agilent technologies microarray chambers
Microarray Chambers, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/pmc10222845-207-19-18?v=Agilent+technologies
Average 90 stars, based on 1 article reviews
microarray chambers - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Agilent technologies microarray hybridization chamber kit
Microarray Hybridization Chamber Kit, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/pmc10127108-156-15-19?v=Agilent+technologies
Average 90 stars, based on 1 article reviews
microarray hybridization chamber kit - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Agilent technologies microarray hybridization chamber
Microarray Hybridization Chamber, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/pm36768818-416-7-6?v=Agilent+technologies
Average 90 stars, based on 1 article reviews
microarray hybridization chamber - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Corning Life Sciences microarray hybridization chambers
Mature miR- 221 is overexpressed in AML. 22 blast-enriched AML samples and 9 healthy controls (3 CD34+, 3 BM, 3 PB), all of which had also been included in the <t>microarray</t> experiments, were subjected to Taqman qRT-PCR to measure mature miR-221 (A) or miR-222 (B) . Expression values were calculated according to the ΔΔCt method , with RNU6B as internal reference and PB from healthy donor A as calibrator. *, p < 0.05; n.s., not significant (miR-222, p = 0.064).
Microarray Hybridization Chambers, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+chambers/pmc03733744-47-7-10?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
microarray hybridization chambers - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


Mature miR- 221 is overexpressed in AML. 22 blast-enriched AML samples and 9 healthy controls (3 CD34+, 3 BM, 3 PB), all of which had also been included in the microarray experiments, were subjected to Taqman qRT-PCR to measure mature miR-221 (A) or miR-222 (B) . Expression values were calculated according to the ΔΔCt method , with RNU6B as internal reference and PB from healthy donor A as calibrator. *, p < 0.05; n.s., not significant (miR-222, p = 0.064).

Journal: BMC Cancer

Article Title: Overexpression of primary microRNA 221/222 in acute myeloid leukemia

doi: 10.1186/1471-2407-13-364

Figure Lengend Snippet: Mature miR- 221 is overexpressed in AML. 22 blast-enriched AML samples and 9 healthy controls (3 CD34+, 3 BM, 3 PB), all of which had also been included in the microarray experiments, were subjected to Taqman qRT-PCR to measure mature miR-221 (A) or miR-222 (B) . Expression values were calculated according to the ΔΔCt method , with RNU6B as internal reference and PB from healthy donor A as calibrator. *, p < 0.05; n.s., not significant (miR-222, p = 0.064).

Article Snippet: Arrays were hybridized overnight at 60°C in microarray hybridization chambers (Corning, Corning, NY, USA).

Techniques: Microarray, Quantitative RT-PCR, Expressing