Review



3d pulmonary imaging software apollo quantitative pulmonary imaging system software  (VIDA Diagnostics)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    VIDA Diagnostics 3d pulmonary imaging software apollo quantitative pulmonary imaging system software
    3d Pulmonary Imaging Software Apollo Quantitative Pulmonary Imaging System Software, supplied by VIDA Diagnostics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+image+analysis+software+package+apollo/us09760989-235-5-20
    Average 90 stars, based on 1 article reviews
    3d pulmonary imaging software apollo quantitative pulmonary imaging system software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Software:

    Article Title: An integrated 1D breathing lung simulation with relative hysteresis of airway structure and regional pressure for healthy and asthmatic human lungs.
    Article Snippet: Sujin Yoon, Tran Minh Tam, Prathish K. Rajaraman, Ching-Long Lin, Merryn Tawhai, Eric A. Hoffman, and X Sanghun Choi School of Mechanical Engineering, Kyungpook National University, Daegu, South Korea; IIHR-Hydroscience and Engineering, University of Iowa, Iowa City, Iowa; Department of Mechanical Engineering, University of Iowa, Iowa City, Iowa; Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa; Department of Radiology, University of Iowa, Iowa City, Iowa; Department of Internal Medicine, University of Iowa, Iowa City, Iowa; and Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand

    Article Title: CT-measured lung air-trapping is associated with higher carotid artery stiffness in individuals with chronic obstructive pulmonary disease
    Article Snippet: .. At the time of the present study, quantitative lung imaging software (APOLLO, VIDA Diagnostics) was used to import, segment, and analyze the CT lung images. ..

    Article Title: Efficacy and Safety of the 9-mm Intrabronchial Valve in Patients with Advanced Emphysema.
    Article Snippet: Background: Endoscopic valve therapy aims at lung volume reduction that is associated with improved lung function, exercise tolerance and quality of life in emphysema patients.. The size of intrabronchial valves of the Spiration® Valve System (SVS) selected to achieve lobar occlusion may have an influence on treatment outcomes.. Methods: 49 severe emphysema patients (M/F: 24/25, age: 64 ± 7 years), with complete interlobar fissures on the side intended to be treated, underwent treatment with at least one 9-mm intrabronchial valve implantation at 3 centers and were followed up at 30, 90 and 180 days after intervention.

    Article Title: Longitudinal Imaging-Based Clusters in Former Smokers of the COPD Cohort Associate with Clinical Characteristics: The SubPopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS)
    Article Snippet: .. All CT scans were processed with an automated commercial pulmonary segmentation software (Apollo 2.0, VIDA Diagnostics) to segment the airways, vessel trees, and lobes. ..

    Article Title: Longitudinal Imaging-Based Clusters in Former Smokers of the COPD Cohort Associate with Clinical Characteristics: The SubPopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS)
    Article Snippet: .. Derivation of qCT Imaging-Based Variables All CT scans were processed with an automated commercial pulmonary segmentation software (Apollo 2.0, VIDA Diagnostics) to segment the airways, vessel trees, and lobes. ..

    other:

    Article Title: Imaging-based clusters in former smokers of the COPD cohort associate with clinical characteristics: the SubPopulations and intermediate outcome measures in COPD study (SPIROMICS)
    Article Snippet: They were segmented with an automated commercial airway/lung segmentation software (Apollo 2.0, VIDA Diagnostics), and registered with a non-rigid mass-preserving imaging registration technique [ , ].

    Article Title: Severe pulmonary hypertension associated with lung disease is characterised by a loss of small pulmonary vessels on quantitative computed tomography
    Article Snippet: Quantitative measurements from CTPA were extracted and computed automatically using Food and Drug Administration-approved lung quantitative imaging software (Apollo v2.0; VIDA Diagnostics, Coralville, IA, USA).

    Article Title: Impact of gastroesophageal reflux on longitudinal lung function and quantitative computed tomography in the COPDGene cohort
    Article Snippet: Quantitative imaging analysis were performed using VIDA (VIDA Diagnostics, Iowa City, IA; http://www.vidadiagnostics.com ) software and Thirona ( https://thirona.eu/ ) software.

    Imaging:

    Article Title: CT-measured lung air-trapping is associated with higher carotid artery stiffness in individuals with chronic obstructive pulmonary disease
    Article Snippet: .. At the time of the present study, quantitative lung imaging software (APOLLO, VIDA Diagnostics) was used to import, segment, and analyze the CT lung images. ..

    Article Title: Efficacy and Safety of the 9-mm Intrabronchial Valve in Patients with Advanced Emphysema.
    Article Snippet: Background: Endoscopic valve therapy aims at lung volume reduction that is associated with improved lung function, exercise tolerance and quality of life in emphysema patients.. The size of intrabronchial valves of the Spiration® Valve System (SVS) selected to achieve lobar occlusion may have an influence on treatment outcomes.. Methods: 49 severe emphysema patients (M/F: 24/25, age: 64 ± 7 years), with complete interlobar fissures on the side intended to be treated, underwent treatment with at least one 9-mm intrabronchial valve implantation at 3 centers and were followed up at 30, 90 and 180 days after intervention.

    Article Title: Longitudinal Imaging-Based Clusters in Former Smokers of the COPD Cohort Associate with Clinical Characteristics: The SubPopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS)
    Article Snippet: .. Derivation of qCT Imaging-Based Variables All CT scans were processed with an automated commercial pulmonary segmentation software (Apollo 2.0, VIDA Diagnostics) to segment the airways, vessel trees, and lobes. ..



    Similar Products

    90
    Imbio LLC software for lung texture analysis
    Software For Lung Texture Analysis, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+texture+analysis/pm40197088-58-4-9
    Average 90 stars, based on 1 article reviews
    software for lung texture analysis - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC lung texture analysis software
    Exemplary results of the <t>multi-texture</t> <t>lung</t> <t>analysis</t> tool and the opacity-based lung analysis tool. CT in coronal view of a 62 year old patient with idiopathic pulmonary fibrosis ( A ), analyzed by the opacity-based Pneumonia tool (Siemens Healthineers), the red lines represent the segmented fibrotic areas ( B ) with additional 3D reconstruction ( C ). ( D ) Analysis with the multi-texture lung analysis tool (CALIPER, Biomedical imaging resource laboratory, Mayo Clinic) with the yellow areas representing fibrotic altered tissue.
    Lung Texture Analysis Software, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+texture+analysis/pmc11718064-66-16-20
    Average 90 stars, based on 1 article reviews
    lung texture analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC ai-based quantitative lung texture analysis software
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Ai Based Quantitative Lung Texture Analysis Software, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+texture+analysis/pmc11675828-87-22-26
    Average 90 stars, based on 1 article reviews
    ai-based quantitative lung texture analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC lung texture analysis software imbio version 22.0
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Lung Texture Analysis Software Imbio Version 22.0, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+texture+analysis/pmc11432915-127-10-10
    Average 90 stars, based on 1 article reviews
    lung texture analysis software imbio version 22.0 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC machine learning software imbio lung texture analysis version 1.4.2
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Machine Learning Software Imbio Lung Texture Analysis Version 1.4.2, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/machine+learning+software+imbio+lung+texture+analysis+version+1+4+2/pm34592744-57-14-17
    Average 90 stars, based on 1 article reviews
    machine learning software imbio lung texture analysis version 1.4.2 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC ct lung texture analysis™ software
    <t>Analysis</t> of <t>lung</t> <t>texture</t> patterns in non-severe and severe COVID-19 based on CT thorax scans. A) Radiological texture analysis per lung field was performed using the IMBIO CT Lung Texture Analysis™ <t>software.</t> B) Lung texture analysis shown for one patient with non-severe COVID-19 and one patient with severe disease with the percentages of normal lung parenchyma, marked in green and abnormal lung parenchyma marked in yellow for ground glass opacities and in orange for reticular pattern. Automated quantification of the lung texture in the upper, middle and lower fields with C) pictograms indicating ground glass opacity pattern localization in patients with non-severe and severe COVID-19, respectively, and D) pictograms of reticular lung texture pattern localization in patients with non-severe and severe COVID-19, respectively. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)
    Ct Lung Texture Analysis™ Software, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+texture+analysis/pmc08058052-66-10-9
    Average 90 stars, based on 1 article reviews
    ct lung texture analysis™ software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC lung texture analysis (lta) (caliper) software
    <t>Analysis</t> of <t>lung</t> <t>texture</t> patterns in non-severe and severe COVID-19 based on CT thorax scans. A) Radiological texture analysis per lung field was performed using the IMBIO CT Lung Texture Analysis™ <t>software.</t> B) Lung texture analysis shown for one patient with non-severe COVID-19 and one patient with severe disease with the percentages of normal lung parenchyma, marked in green and abnormal lung parenchyma marked in yellow for ground glass opacities and in orange for reticular pattern. Automated quantification of the lung texture in the upper, middle and lower fields with C) pictograms indicating ground glass opacity pattern localization in patients with non-severe and severe COVID-19, respectively, and D) pictograms of reticular lung texture pattern localization in patients with non-severe and severe COVID-19, respectively. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)
    Lung Texture Analysis (Lta) (Caliper) Software, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lung+texture+analysis+software/lung+texture+analysis/ppr0302742-55-14-13
    Average 90 stars, based on 1 article reviews
    lung texture analysis (lta) (caliper) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Exemplary results of the multi-texture lung analysis tool and the opacity-based lung analysis tool. CT in coronal view of a 62 year old patient with idiopathic pulmonary fibrosis ( A ), analyzed by the opacity-based Pneumonia tool (Siemens Healthineers), the red lines represent the segmented fibrotic areas ( B ) with additional 3D reconstruction ( C ). ( D ) Analysis with the multi-texture lung analysis tool (CALIPER, Biomedical imaging resource laboratory, Mayo Clinic) with the yellow areas representing fibrotic altered tissue.

    Journal: Scientific Reports

    Article Title: Comparing multi-texture fibrosis analysis versus binary opacity-based abnormality detection for quantitative assessment of idiopathic pulmonary fibrosis

    doi: 10.1038/s41598-025-85135-7

    Figure Lengend Snippet: Exemplary results of the multi-texture lung analysis tool and the opacity-based lung analysis tool. CT in coronal view of a 62 year old patient with idiopathic pulmonary fibrosis ( A ), analyzed by the opacity-based Pneumonia tool (Siemens Healthineers), the red lines represent the segmented fibrotic areas ( B ) with additional 3D reconstruction ( C ). ( D ) Analysis with the multi-texture lung analysis tool (CALIPER, Biomedical imaging resource laboratory, Mayo Clinic) with the yellow areas representing fibrotic altered tissue.

    Article Snippet: The computer-aided lung informatics for pathology evaluation and ratings (CALIPER) tool is part of the Imbio lung texture analysis software (Imbio) and was created by the Biomedical Imaging Resource Laboratory of the Mayo Clinic, Minnesota.

    Techniques: Imaging

    Linear regression analyses. Illustration of regression analysis between the opacity-based fibrotic lung (OFL) and the multi-texture fibrotic lung (MTFL) quantification, as well as regression analysis of OFL and MTFL with spirometry parameters with Pearson correlation coefficient (r) bigger than 0.25. 95% confidence intervals are indicated by light-colored areas. TLC percent predicted total lung capacity, VC percent predicted vital capacity and DL CO diffusing capacity of the lungs for carbon monoxide.

    Journal: Scientific Reports

    Article Title: Comparing multi-texture fibrosis analysis versus binary opacity-based abnormality detection for quantitative assessment of idiopathic pulmonary fibrosis

    doi: 10.1038/s41598-025-85135-7

    Figure Lengend Snippet: Linear regression analyses. Illustration of regression analysis between the opacity-based fibrotic lung (OFL) and the multi-texture fibrotic lung (MTFL) quantification, as well as regression analysis of OFL and MTFL with spirometry parameters with Pearson correlation coefficient (r) bigger than 0.25. 95% confidence intervals are indicated by light-colored areas. TLC percent predicted total lung capacity, VC percent predicted vital capacity and DL CO diffusing capacity of the lungs for carbon monoxide.

    Article Snippet: The computer-aided lung informatics for pathology evaluation and ratings (CALIPER) tool is part of the Imbio lung texture analysis software (Imbio) and was created by the Biomedical Imaging Resource Laboratory of the Mayo Clinic, Minnesota.

    Techniques:

    Bland-Altman analysis. The opacity-based fibrotic lung (OFL) quantifications was compared to the multi-texture fibrotic lung (MTFL) measurements.

    Journal: Scientific Reports

    Article Title: Comparing multi-texture fibrosis analysis versus binary opacity-based abnormality detection for quantitative assessment of idiopathic pulmonary fibrosis

    doi: 10.1038/s41598-025-85135-7

    Figure Lengend Snippet: Bland-Altman analysis. The opacity-based fibrotic lung (OFL) quantifications was compared to the multi-texture fibrotic lung (MTFL) measurements.

    Article Snippet: The computer-aided lung informatics for pathology evaluation and ratings (CALIPER) tool is part of the Imbio lung texture analysis software (Imbio) and was created by the Biomedical Imaging Resource Laboratory of the Mayo Clinic, Minnesota.

    Techniques:

    Lung texture analysis report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.

    Journal: Diagnostics

    Article Title: Artificial Intelligence Unveils the Unseen: Mapping Novel Lung Patterns in Bronchiectasis via Texture Analysis

    doi: 10.3390/diagnostics14242883

    Figure Lengend Snippet: Lung texture analysis report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.

    Article Snippet: This study aimed to assess lung involvement in patients with bronchiectasis using the Bronchiectasis Radiologically Indexed CT Score (BRICS) and AI-based quantitative lung texture analysis software (IMBIO, Version 2.2.0).

    Techniques:

    Analysis of lung texture patterns in non-severe and severe COVID-19 based on CT thorax scans. A) Radiological texture analysis per lung field was performed using the IMBIO CT Lung Texture Analysis™ software. B) Lung texture analysis shown for one patient with non-severe COVID-19 and one patient with severe disease with the percentages of normal lung parenchyma, marked in green and abnormal lung parenchyma marked in yellow for ground glass opacities and in orange for reticular pattern. Automated quantification of the lung texture in the upper, middle and lower fields with C) pictograms indicating ground glass opacity pattern localization in patients with non-severe and severe COVID-19, respectively, and D) pictograms of reticular lung texture pattern localization in patients with non-severe and severe COVID-19, respectively. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)

    Journal: Clinical Imaging

    Article Title: Automated quantitative thin slice volumetric low dose CT analysis predicts disease severity in COVID-19 patients

    doi: 10.1016/j.clinimag.2021.04.008

    Figure Lengend Snippet: Analysis of lung texture patterns in non-severe and severe COVID-19 based on CT thorax scans. A) Radiological texture analysis per lung field was performed using the IMBIO CT Lung Texture Analysis™ software. B) Lung texture analysis shown for one patient with non-severe COVID-19 and one patient with severe disease with the percentages of normal lung parenchyma, marked in green and abnormal lung parenchyma marked in yellow for ground glass opacities and in orange for reticular pattern. Automated quantification of the lung texture in the upper, middle and lower fields with C) pictograms indicating ground glass opacity pattern localization in patients with non-severe and severe COVID-19, respectively, and D) pictograms of reticular lung texture pattern localization in patients with non-severe and severe COVID-19, respectively. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)

    Article Snippet: Fully automated quantification of CT scans was performed via IMBIO CT Lung Texture analysis™ software.

    Techniques: Software